-18%

CMM-10 Multimeter

Availability:

5 in stock


  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).

11,844 14,478

5 in stock

Compare

The most important features of CMM-10 are:

  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).
Category:
Weight 0.2 kg
Dimensions 14 × 7 × 4 cm

Frequency measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
50,00 Hz 0,01 Hz
500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
5,000 kHz 0,001 kHz
50,00 kHz 0,01 kHz
500,0 kHz 0,1 kHz
5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
10,00 MHz 0,01 MHz
  • sensitivity: ≥8 V RMS

Duty cycle measurement

Range Resolution Accuracy
0,1…99,9% 0,1% ±(1,2% m.v. + 2 digits)
  • sensitivity: ≥8 V RMS,
  • pulse width: 100µs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy*
-20°C…+760°C 1°C ±(3% m.v. + 5°C, 9°F)
-4°F…+1400°F 1°F

*) probe (K type) accuracy not included

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
400,0 V 0,1 V
600 V 1 V ±(1,5% m.v. + 2 digits)
  • input impedance: 7,8 MΩ

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
400,0 V 0,1 V
600 V 1 V ±(2,0% m.v. + 4 digits)
  • input impedance: 7,8 MΩ,
  • frequency range: 50…400 Hz.

DC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
4 000 μA 1 μA ±(1,5% m.v. + 3 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
10,00 A 0,01 A

AC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,5% m.v. + 5 digits)
4 000 μA 1 μA ±(1,8% m.v. + 5 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(3,0% m.v. + 7 digitgs)
10,00 A 0,01 A
  • frequency range: 50…400 Hz.

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ
4,000 MΩ 0,001 MΩ
40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
4,000 μF 0,001 μF
40,00 μF 0,01 μF
100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

“m.v” = measured value

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT II 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,3 mA, U0 = 1,5 V DC
  • continuity test: I<0,3 mA, sound signal for R<50 Ω
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 7,8 MΩ (V AC/DC)
  • display: 5000 counts LCD display with function indication
  • dimensions: 138 x 68 x 37 mm
  • weight: approx. 210 g
  • fuses: mA, µA range: 0,5 A/250 V fast; A range: 10 A/250 V fast
  • auto power OFF: 30 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • operating temperature: 0…+50°C at <70% rel. humidity
  • storage temperature: -20…+60°C at <80% rel. humidity

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-10 Multimeter”

There are no reviews yet.

  • UT620 Series Digital Micro Ohm Meters

    0 out of 5
    (0)

    UT620 series are used to measure DC low resistance through 4-wire method. Some of its features are: Comparison function to determine if the device is in good condition, unknown wire length calculation (FT/M); two-way data transmission by USB interface; built-in rechargeable lithium battery. UT620 can be used in narrow space for on-site troubleshooting, such as metal coating resistance/motor and small transformer winding resistance measurement, earth system joints/welding points/power distribution cabinet bus and lead connection inspection and more.

    SKU: UN62B0TUOM
  • UT 371Series Tachometers

    0 out of 5
    (0)

    Features of UT371 Series Tachometers

    Certificates: CE, UKCA

    ● 5 digits LCD screen, RPM/count and time dual display
    ● MAX/MIN/AVG/normal modes
    ● Adjustable sampling rate (0.5-255s)
    ● Auto power off (cancelable)

    ● Optional (on/off) laser pointer
    ● Clock and time setting
    ● Data hold, low power consumption, continuous work for 40hrs

    SKU: n/a
  • DIGITAL INSULATION / CONTINUITY TESTER MODEL 3005A

    0 out of 5
    (0)

    • Bargraph to display insulation resistance.
    • Displays the value of external AC voltage along with flashing symbol.
    • Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
    • Live circuit warning beeper.
    • Releasing the test button automatically discharges the charges stored in the circuit under test.
    • 200mA continuity measuring current to IEC 61557.
    • Minimum 1mA current on insulation tests to IEC 61557.

    SKU: n/a
  • AC/DC DIGITAL CLAMP METER KEW 2046R

    0 out of 5
    (0)

    • Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
    • CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
    • Very useful for power distribution companies, power utilities and maintenance fields.
    • True RMS enables an accurate measurement.

    SKU: n/a