Fluke 15B+ Digital Multimeter

Availability:

Out of stock


Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • UT256A

    0 out of 5
    (0)

    UT256 series are high reliable, true RMS fork meters. Its unique design allows users to measure current by simply moving the wire ofinterest inside the opening of the ‘fork’ past the labeled mark. With no mechanical parts, this meter bares no risk from any type ofmechanical failure.

    SKU: n/a
  • Micro Lens UT-Z002

    0 out of 5
    (0)
    SKU: n/a
  • KT-650 Thermal Imager

    0 out of 5
    (0)
    • High resolution IR images up to 120,000 pixels (400x) and 307,200 pixels (640×480) alternative
    • Visible light digital camera 5MP resolution with LED lamp provides sharp images regardless of lighting conditions
    • 5 inch 720P high resolution LCD touch screen for better image clarity and easy operation
    • Rotating LCD display up to 270″ for easy viewing angle
    • Rotating lens detents up to 70″ for easy viewing angle
    • 4x (10x for plus version) continuous zoom with auto/motorized focus
    • Android based operation system with open platform for various APP developments and convinient program updating
    • Powerful onboard analysis and reporting capabilities
    • Multiple image presentation including IR visible, PIP and IR blending
    • WiFi&Bluetooth wireless communication
    • Optional high temperature range measuring up to 2000oC (3632oF) targeting electrical and industrial applications
    • Optional 11o telephoto or 45o wide angle lens
    SKU: n/a
  • UT501A Insulation Resistance Tester

    0 out of 5
    (0)

    1. 2000 count LCD display, overload indication, backlight

    2. AC voltage measurement, auto power off
    3. Auto discharge
    4. Continuous measurements mode, red warning light and buzzer function
    SKU: n/a
  • Digital Clamp Meter UT202+ UNI-T

    0 out of 5
    (0)
    Specifications Range UT202+
    AC current (A) 400A ±(2%+10)
    600A
    AC current frequency (Hz) 50Hz~100Hz ±(1%+5)
    AC voltage (V) 600V ±(0.8%+5)
    AC voltage frequency(Hz) 10Hz~10kHz ±(1%+5)
    10Hz~60kHz
    Resistance (Ω) 40MΩ ±(0.8%+2)
    60MΩ
    Capacitance (F) 4mF ±(4%+5)
    40mF
    60mF
    Temperature (℃) -40℃~1000℃ ±(1.5%+5)
    Frequency (Hz) 10Hz~10MHz
    Features
    Display count 4000
    Auto range
    Jaw opening 28mm
    True RMS
    NCV
    Live wire test
    Continuity test
    Diode
    MAX/MIN
    Relative mode
    Zero mode
    Data hold
    Low battery indication
    Auto power off
    General Characterisitics
    Power 1.5V battery (R03) x 2
    Display 37mm x 25mm
    Product color Red and grey
    Product net weight 248g
    Product size 215mm x 63mm x 36mm
    Standard accessories Batteries, test leads, Themocouple
    Standard individual packing Gift box, Carring bag, English manual
    Standard quantity per carton 40pcs
    Standard carton measurement 485mm x 295mm x 385mm
    Standard carton gross weight 17.8kg
    SKU: n/a