-6%

UT210E ACA DCA Digital Clamp Meters


Main Features

1. Auto range, 2~3/s sampling rate

2. True RMS measurement

3. VFC, frequency conversion function

4. NCV, Non-Contact Voltage testing function:induce electric field strength via the jaw

5. Zero mode

6. LCD backlight, data hold

7. Auto power off, low battery indication and overload protection

8. Comfortable to hold and easy to carry with (Product weight: 160g/170g)

9. Complies with CE (European Union) directives

13,200 14,026

Compare

Main Features

1. Auto range, 2~3/s sampling rate

2. True RMS measurement

3. VFC, frequency conversion function

4. NCV, Non-Contact Voltage testing function:induce electric field strength via the jaw

5. Zero mode

6. LCD backlight, data hold

7. Auto power off, low battery indication and overload protection

8. Comfortable to hold and easy to carry with (Product weight: 160g/170g)

9. Complies with CE (European Union) directives

Category:
Weight 0.2 kg
Dimensions 17 × 6 × 3 cm
Specifications Range Best Accuracy
Model UT210E
AC Current (A) 20A/200A
2A/20A/100A ±(2.5%+5)
DC Current (A) 20A/200A
2A/20A/100A ±(2%+3)
AC Voltage (V) 2V/20V/200V/600V ±(1%+3)
DC Voltage (V) 200mV/2V/20V/200V/600V ±(0.7%+3)
Resistance (Ω) 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ ±(1%+2)
Frequency 10Hz/100Hz/1kHz/10kHz/60kHz
Capacitance    (F) 2nF/20nF/200nF/2μF
/20μF/200μF/2mF/20mF
±(4%+5)
Temperature (℃) -40~1000℃
Temperature (℉) -40~1832℉
Features
Display Count 2000
Auto Range
Jaw Capacity 17mm
True RMS
Diode Around 3.0V
V.F.C.
NCV
Auto Power Off Around 15 minutes
Continuity    Buzzer
Low Battery Indication ≤2.5V
Data Hold
Zero Mode
MAX/MIN
LCD Backlight
Input    Protection
Input Impedance for DCV ≥10MΩ
General Characteristics 
Power AAA 1.5V x 2
LCD Size 39.3mm x 26.5mm
Product Color Red and grey
Product Net Weight 170g
Product Size 175mm x 60mm x 33.5mm
Standard Accessories Batteries, Test Lead
Standard Individual Packing Gift  Box, Carrying bag, English Manual

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT210E ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • MC TIP 900M TIS

    0 out of 5
    (0)
    SKU: n/a
  • ET 8133 DMM

    0 out of 5
    (0)

    Product description

    3 times/second
    Diode: YES
    Capacitance: YES
    True RMS: YES
    Data hold: YES
    Backlight: YES
    Flashlight: YES
    Auto power off: YES (no measurement operation within 15 minutes)
    Low battery indication: YES
    Environment temperature: 0~40℃, humidity <75%
    Storage environment: -20~60℃, humidity <80%
    DC voltage:
    Range: 200mV/2.000V/20.00V/200.0V/600V
    Resolution: 0.0001V/0.001V/0.01V/0.1V/1V
    Accuracy: ±(0.5%+3)
    Max.: 600V
    AC voltage:
    Range: 2.000V/20.00V/200.0V/600V
    Resolution: 0.001V/0.01V/0.1V/1V
    Accuracy: ±(1.0%+3)
    Max.: 600V
    Capacitance:
    Range: 20.00nF/200.0nF/2.000F/200.0F
    Resolution: 0.01nF/0.1nF/10nF/100nF
    Accuracy: ±5%+3
    Max.: 200μF
    AC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA/2A: ±(1.0%+3)
    10A: ±(1.5%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    DC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA: ±(2.0%+4)
    2A: ±(1.0%+5)
    10A: ±(2.0%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    Resistance:
    Range: 2.000KΩ/20.00KΩ/200.0KΩ/2.000MΩ/20.00MΩ
    Resolution: 0.001KΩ/0.01KΩ/0.1KΩ/0.001MΩ/0.01MΩ
    Accuracy:
    2.000KΩ: ±(1.5%+3)
    20.00KΩ: ±(0.5%+3)
    200.0KΩ: ±(0.5%+3)
    2.000MΩ: ±(1.0%+3)
    20.00MΩ: ±(1.5%+3)
    Max.: 20MΩ
    Continuity: YES
    NCV: YES
    Frequency response in AC mode: 40Hz~1KHz
    LCD size: 45 * 25mm / 1.8 * 1.0in
    Item size: 124 * 65 * 26mm / 4.9 * 2.6 * 1.0in
    Item weight: 210g / 7.4ounce
    Package size: 140 * 100 * 40mm / 5.5 * 3.9 * 1.6in
    Package weight: 220g / 7.8ounce

    SKU: n/a
  • Fluke 18B+ Digital Multimeter

    0 out of 5
    (0)

    Feature:

    -New Function:Frequency Test

    -New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light

    -Two Mode LED Test :

    -DMM LED Socket Test Mode .

    -UUT(PCBA) LED Test Mode(using test lead).

    -Light up LED without considering the polarity.

    -Voltage,Resistance,Continuity Testing,Capacitance Test.

    -Data Hold,Diode Test.

    -Frequency and Duty Cycle.

    -MAX Input Current 10A.

     

     

    SKU: n/a
  • MECHANIC RD Series lead-free ESD soldering tip 900M-T-I

    0 out of 5
    (0)

    MECHANIC RD Series lead-free ESD soldering tip 900M-T-I

    Good heat conduction, fast heating, corrosion resistance, antistatic,long service life

    SKU: n/a
  • A25D PM2.5 Meter

    0 out of 5
    (0)

    Main features

    1. Precise PM2.5 concentration based on pre-calibrated sensors

    2. Temperature measurement (℃/℉)

    3. Humidity measurement

    4. Emoticon display

    5. LCD backlight and red backlight alarm

    6. battery status, low power, auto power off

    SKU: n/a