UT312 Vibration Tester
UT310 series handheld vibration testers can measure displacement, velocity, and acceleration of rotating and reciprocating machinery. Technicians can use these to monitor equipment status and ensure normal operation.
10 in stock
1. Highly accurate and precise
₨85,000 ₨97,000
10 in stock
CompareUT310 series handheld vibration testers can measure displacement, velocity, and acceleration of rotating and reciprocating machinery. Technicians can use these to monitor equipment status and ensure normal operation.
Weight | 0.2 kg |
---|---|
Dimensions | 18 × 7 × 3 cm |
Specifications | Range | UT312 |
Acceleration (O-P) | 0.1~199.9m/s² | Frequency response: 10~1500Hz, Amplitude error: ≤±5% |
Amplitude linear error: ≤2.0m/s², ≤±10%; >2.0m/s², ≤±5% | ||
Velocity (RMS) | 0.1~199.9mm/s | Frequency response: 10~1500Hz, Amplitude error: ≤±5% |
Amplitude linear error: ≤2.0m/s, ≤±10%; >2.0m/s, ≤±5% | ||
Displacement (P-P) | 1~1999μm | Frequency response: 10~500Hz, Amplitude error: ≤±5% |
Amplitude linear error: ≤20um, ≤±10%; >20um, ≤±5% | ||
Features | ||
Data hold | √(auto data hold when releasing the measure key) | |
Low battery indication | √ | |
Auto power off | √(auto power off 1 minute after releasing the measure key) | |
Battery life | Continuous measuring time > 20 hours | |
Display count | 2000 | |
General Characterisitics | ||
Power | 9V battery (6F22 ) | |
Product color | Red and grey | |
Product net weight | 230g (including battery) | |
Product size | 185mm x 68mm x 30mm | |
Standard accessories | Battery, tool box | |
Standard individual packing | Gift box, English manual | |
Standard quantity per carton | 5pcs | |
Standard carton measurement | 375mm x 307mm x 246mm | |
Standard carton gross weight | 5.8kg |
UT363/UT363BT are mini wind speed and temperature meters. UT363 and UT363BTcan measure wind speeds up to 30m/s.
UT363BT can transfer measurement data through bluetooth to UNI-T’s custom mobile APP (iENV) for further analysis, storage, and export. iENV can be downloaded from Google Play, Apple Store or UNI-T’s website by searching ‘iENV’.
3 times/second
Diode: YES
Capacitance: YES
True RMS: YES
Data hold: YES
Backlight: YES
Flashlight: YES
Auto power off: YES (no measurement operation within 15 minutes)
Low battery indication: YES
Environment temperature: 0~40℃, humidity <75%
Storage environment: -20~60℃, humidity <80%
DC voltage:
Range: 200mV/2.000V/20.00V/200.0V/600V
Resolution: 0.0001V/0.001V/0.01V/0.1V/1V
Accuracy: ±(0.5%+3)
Max.: 600V
AC voltage:
Range: 2.000V/20.00V/200.0V/600V
Resolution: 0.001V/0.01V/0.1V/1V
Accuracy: ±(1.0%+3)
Max.: 600V
Capacitance:
Range: 20.00nF/200.0nF/2.000F/200.0F
Resolution: 0.01nF/0.1nF/10nF/100nF
Accuracy: ±5%+3
Max.: 200μF
AC current:
Range: 20mA/200mA, 2A, 10A
Resolution: 0.1mA/0.001A/0.01A
Accuracy:
20mA/200mA/2A: ±(1.0%+3)
10A: ±(1.5%+3)
Max.:
20mA/200mA: 200mA
2A/10A: 10A
DC current:
Range: 20mA/200mA, 2A, 10A
Resolution: 0.1mA/0.001A/0.01A
Accuracy:
20mA/200mA: ±(2.0%+4)
2A: ±(1.0%+5)
10A: ±(2.0%+3)
Max.:
20mA/200mA: 200mA
2A/10A: 10A
Resistance:
Range: 2.000KΩ/20.00KΩ/200.0KΩ/2.000MΩ/20.00MΩ
Resolution: 0.001KΩ/0.01KΩ/0.1KΩ/0.001MΩ/0.01MΩ
Accuracy:
2.000KΩ: ±(1.5%+3)
20.00KΩ: ±(0.5%+3)
200.0KΩ: ±(0.5%+3)
2.000MΩ: ±(1.0%+3)
20.00MΩ: ±(1.5%+3)
Max.: 20MΩ
Continuity: YES
NCV: YES
Frequency response in AC mode: 40Hz~1KHz
LCD size: 45 * 25mm / 1.8 * 1.0in
Item size: 124 * 65 * 26mm / 4.9 * 2.6 * 1.0in
Item weight: 210g / 7.4ounce
Package size: 140 * 100 * 40mm / 5.5 * 3.9 * 1.6in
Package weight: 220g / 7.8ounce
Analog bandwidth | 150MHz | 250MHz | ||
Channels | 2+16 digital | 4+16 digital | 2+16 digital | 4+ 16digital |
Sampling rate (Analog) | 2.5GS/s (Single channel), 1.25GS/s (Dual channels) | |||
Sampling rate (Digital) | 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) | |||
Memory depth | 70Mpts | |||
Waveform capture rate | 200,000wfms/s | |||
Time base scale | 2ns/div~50s/div (Real-time sampling rate, memory depth display ) | |||
Time base scale (digital) | 2ns/div~40S/div[Step by 1-2-4 stall] | |||
Input impedance | (1MΩ±1%) II (20pF±3pF) | |||
Input impedance digital | (101kΩ±1%) II (9pF±1pF) | |||
Vertical scale | 1mV/div~20 V/div (1 MΩ) | |||
DC gain accuracy | <5mV: ±3%, ≥5mV: ±2% | |||
Waveform record | 100,000 frames | |||
Trigger types | Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay |
|||
Bus decode | RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay | |||
Waveform operations | A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations | |||
Auto measurements |
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A |
|||
Measurement display | 5 types | |||
Measurement statistics | Average, Max, Min, standard deviation and number of measurements | |||
Frequency counter | 6 bits | |||
Standard interfaces | USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA | |||
Standard Accessories |
USB interface cable | UT-D14 | ||
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) | UT-P06 | |||
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) | UT-P05 | |||
16CH Logic analyzer probe | UT-15M |
There are no reviews yet.