• MIC-2501,2500V Insulation Resistance Meter

    0 out of 5
    (0)

     

    Electrical safety:

    • type of insulation: double, in acc. with EN 61010-1 und IEC 61557
    • measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
    • case protection rating in acc. with EN 60529: IP65

    Other technical specifications:

    • power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
    • weight of the meter: approx. 0,9 kg
    • dimensions: 200 x 180 x 77 mm
    • display: LCD segment display
    • measurement results memory: 990 cells, 11880 records,
    • transmission of measurement results: USB
    SKU: n/a
  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a
  • MRU-10 Earth Resistance Meter

    0 out of 5
    (0)

    It allows to:

    • measure earthing resistance using auxiliary electrodes,
    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network with frequency 50 Hz and 60 Hz,
    • selection of maximum measuring voltage (25 V and 50 V),
    • indication of battery state.
    SKU: n/a
  • MRU-21 Earth Resistance Meter

    0 out of 5
    (0)

    Possible measurements:

    • earth resistance measurment with 3-pole method,
    • measurement of continuity of equipotential bondings and protective conductors with auto-zero function – with current 200 mA,
    • resistance measurement using 2-pole method.
    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a
  • PQM-707 Power Quality Analyzer

    0 out of 5
    (0)
    • Features:

      • 7″ touch screen – intuitive operating
      • CAT IV 600V – high safety
      • all parameters acc. to class S – high accuracy of measurements
      • Li-Ion rechargeable battery – higher mobility
      • removable memory card – recording data with no restrictions

      Possible measurements:

      • Measurements according to EN 50160,
      • Voltage L1, L2, L3, N-PE (five inputs),
        – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
      • Current L1, L2, L3, N (four inputs),
        – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
      • Crest factor for voltage and current,
      • Frequency from 40 Hz to 70 Hz ,
      • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
      • Power recording:
        • Budeanu method,
        • IEEE 1459,
      • Active, reactive, apparent energy,
      • Power factor, cosφ, tgφ,
      • Up to 50th harmonics for voltage and current,
      • Total Harmonic Distortion (THD) for voltage and current,
      • Short-term (PST) and long-term (PLT) flicker,
      • Unbalance of voltage and current,
      • Current and voltage events registration including waveforms and RMS graphs half period,
      • Inrush current
      • Calculator of energy tariffs
      • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
    SKU: n/a
  • TDR-410 Cable Fault Locator

    0 out of 5
    (0)
    • Features:

      • automatic or manual mode:
        • the automatic fault location (AFL),
        • mode with manual range selection and sensitivity,
        • single measurement triggered manually or scanning continuous,
      • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
      • maximum length of cable up to 4000 m one end of the cable,
      • “Dead zone” measure limited to 0.5 m,
      • 2.5 “LCD screen with backlight,
      • scan automatically or manually trigger,
      • sensitivity set manually or automatically adjusted,
      • adjustable impedance matching,
      • propagation coefficient adjustment 1% to 99%,
      • waterproof and resistant to mechanical housing.
      • small size and weight.
      • economical power system – 30 hours of continuously scan on one battery set..

      Accessories:

      • 0,6 m double-wire lead: WAPRZ0X6DZBB
      • red crocodile clip: WAKRORE20K02
      • Krokodylek czarny: WAKROBL20K01
      • cover M-2: WAFUTM2
    SKU: n/a
  • TDR-420 Time Domain Reflectometer/ Cable Fault Locator

    0 out of 5
    (0)

    Product features

    • Possibility damage-free location of impedance changes of tested cables and wires such as:
      • shorted conductor,
      • open conductor / end of cable – useful during the inventory of warehouses and stores,
      • splice,
      • splitter,
      • water ingress,
      • wet splice,
      • bridge tap
      • or other changes.
    • Single measurement mode ONCE,
    • Continuously measurement mode CONT,
    • Tone signal generator TONE,
    • Two cursors to mark two places of damage along with an indication of the distance between them,
    • Built-in HELP function for easier interpretation of the reflectogram,
    • 11 available measuring ranges from 7 m to 6000 m,
    • „dead zone” limited to 0.6 m,
    • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
    • manually set of sensitivity in 8 steps GAIN,
    • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
    • Velocity of Propagation set in range from 10% to 99%,
    • tight and durable housing with IP67 ingress protection degree.
    • Small size and weight.
    SKU: n/a
  • TKF-12 Phase Sequence Tester

    0 out of 5
    (0)

    Phase sequence indication (direction of field rotation) in the power network with rated phase-to-phase voltage (120…690 V) AC by LED signalization.
    Operation in the power network with frequency range 10…70 Hz.

    Indication of the voltage presence in the particular phases by neon lamps signalization.
    Power supply from the tested network (continuous operation to 15 minutes for max. voltage).
    Protection against faulty indication of field rotation.

    SKU: n/a

Showing 16–24 of 24 results