Category:
Specifications Range Resolution Precision
Model A37
Carbon dioxide 400ppm~5000ppm 1ppm ±5%rdg + 50ppm from 400ppm~2000ppm (at ambient temperature and humidity)
Temperature  -10.0℃~50.0℃ 0.1℃ Typical accuracy: ±1℃
Relative humidity  0%RH~99%RH 1%RH Typical accuracy: ±5%RH (10%RH~90%RH) at 25℃
Features
ABC Automatic baseline correction
Audible and visual alarm
Sensor type NDIR (no-dispersive infra) CO2 sensor
Response time T90 < 2 minutes
Date/time Display the date and time
Low power display low power symbol keep flashing
Auto power off auto power off if no opeartion for long time
Backlight The white backlight can be turned on/off.
It will be automatically turned off after 20-minute inactivity.
Operating temperature 0℃~50℃, 0%RH~85%RH
Storage temperature -20℃~60℃, 0%RH~95%RH
General Characteristics 
Power 3.7V DC Li-ion battery/ Micro USB charging port
LCD size 42 x 65mm
Product color White
Product net weight about 195g
Product size 75 x 55 x 130mm
Standard accessory Micro USB charging cable
Standard individual packing Gift box, English manual

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “A37 CO2 Meter”

There are no reviews yet.

  • UNI-T UT3513 DC Resistance Tester Microohmmeter 4.3 Inch LCD Screen Cable/Coil/Motor Resistance Test

    0 out of 5
    (0)
    Model UT3513
    Resistance range 20m Q/200m Q/2Q/20Q /200 Q/2kQ/20kQ
    Resolution 1 u Q/10 u Q/100 u Q/lmO/lOmQ/lOOmQ/1 Q/10Q/100Q
    Test current 1A/1A/100mA/10mA/1mA/1mA/100 uA/10 u A/l uA
    Testing terminal opencircuit voltage <1V/<1V/<1V/<1V/<5V/<5V/<5V/<5V/<3V/
    Measured parameter DC resistance
    Basic accuracy Slow: 0. 1%; Medium: 0. 2%
    Maximum reading 22000
    Range mode Auto/Manual/nominal
    Calibration Short-circuit full range zeroing
    Sorting function 3types of resistance and voltage input: exceeds upper limit/exceeds lower limit/within the range,2 types of sorting result output: PASS/FAIL
    Comparing method Absolute tolerance, percentage tolerance, direct-reading comparison
    Trigger mode Internal, external
    Test terminal Four-terminal measurement
    Button functions Lock 一一 keyboard lock, OK 一一 screenshot
    System setup Language: Chinese/English, key tone setting
    Interfaces & protocols Handler interface, RS232, USB DEVICE and USB HOST communication interface,SCPI and Modbus protocol
    Upper computer software V
    Power AC 100~240V 50/60Hz
    Display 4.3-inches LCD
    SKU: n/a
  • SVC 7000VA

    0 out of 5
    (0)

    Input=120V 270
    Output=220
    Under and Over Volt Protection
    Surge Protection
    Over Load and Heat Protection
    Copper Wind with LCD Display

    SKU: n/a
  • UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • UT-L 33Test Leads

    0 out of 5
    (0)
    SKU: n/a
  • UPO1202CS

    0 out of 5
    (0)
    SKU: n/a
  • YH 908B

    0 out of 5
    (0)
    SKU: n/a