Main Features
1. Automatic baseline correction
2. Audible and visual alarm
3. Low battery indication
4. Auto power off
5. Backlight
Main Features
1. Automatic baseline correction
2. Audible and visual alarm
3. Low battery indication
4. Auto power off
5. Backlight
₨30,000 ₨33,544
Main Features
1. Automatic baseline correction
2. Audible and visual alarm
3. Low battery indication
4. Auto power off
5. Backlight
Specifications | Range | Resolution | Precision |
Model | A37 | ||
Carbon dioxide | 400ppm~5000ppm | 1ppm | ±5%rdg + 50ppm from 400ppm~2000ppm (at ambient temperature and humidity) |
Temperature | -10.0℃~50.0℃ | 0.1℃ | Typical accuracy: ±1℃ |
Relative humidity | 0%RH~99%RH | 1%RH | Typical accuracy: ±5%RH (10%RH~90%RH) at 25℃ |
Features | |||
ABC | Automatic baseline correction | √ | |
Audible and visual alarm | √ | ||
Sensor type | NDIR (no-dispersive infra) CO2 sensor | √ | |
Response time | T90 < 2 minutes | √ | |
Date/time | Display the date and time | √ | |
Low power display | low power symbol keep flashing | √ | |
Auto power off | auto power off if no opeartion for long time | √ | |
Backlight | The white backlight can be turned on/off. It will be automatically turned off after 20-minute inactivity. |
√ | |
Operating temperature | 0℃~50℃, 0%RH~85%RH | √ | |
Storage temperature | -20℃~60℃, 0%RH~95%RH | √ | |
General Characteristics | |||
Power | 3.7V DC Li-ion battery/ Micro USB charging port | ||
LCD size | 42 x 65mm | ||
Product color | White | ||
Product net weight | about 195g | ||
Product size | 75 x 55 x 130mm | ||
Standard accessory | Micro USB charging cable | ||
Standard individual packing | Gift box, English manual |
Features:
Analog bandwidth | 150MHz | 250MHz | ||
Channels | 2+16 digital | 4+16 digital | 2+16 digital | 4+ 16digital |
Sampling rate (Analog) | 2.5GS/s (Single channel), 1.25GS/s (Dual channels) | |||
Sampling rate (Digital) | 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) | |||
Memory depth | 70Mpts | |||
Waveform capture rate | 200,000wfms/s | |||
Time base scale | 2ns/div~50s/div (Real-time sampling rate, memory depth display ) | |||
Time base scale (digital) | 2ns/div~40S/div[Step by 1-2-4 stall] | |||
Input impedance | (1MΩ±1%) II (20pF±3pF) | |||
Input impedance digital | (101kΩ±1%) II (9pF±1pF) | |||
Vertical scale | 1mV/div~20 V/div (1 MΩ) | |||
DC gain accuracy | <5mV: ±3%, ≥5mV: ±2% | |||
Waveform record | 100,000 frames | |||
Trigger types | Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay |
|||
Bus decode | RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay | |||
Waveform operations | A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations | |||
Auto measurements |
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A |
|||
Measurement display | 5 types | |||
Measurement statistics | Average, Max, Min, standard deviation and number of measurements | |||
Frequency counter | 6 bits | |||
Standard interfaces | USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA | |||
Standard Accessories |
USB interface cable | UT-D14 | ||
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) | UT-P06 | |||
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) | UT-P05 | |||
16CH Logic analyzer probe | UT-15M |