These 1000A AC/DC digital clamp meters are stable, safe and reliable with low power consumption. Its full range overload protection and unique appearance design make these clamp meters the ideal tool for maintenance and repair of electrical and power lines up to 1000A AC.
Clamp Meters
UT 208 CLAMP METER
Availability:
10 in stock
1. 1000A AC/DC current measurement, 3 times/s sampling rate
2. True RMS
3. Inrush current
4. Zeroing function
5. Full icon display
6. MAX/MIN
7. Data hold; Duty cycle
8. Auto power off and low battery indication
9. Point contact temperature probe
10. Diode; Continuity buzzer; Input Impedance for DCV
₨22,200 ₨24,556
10 in stock
CompareWeight | 0.5 kg |
---|---|
Dimensions | 29 × 10 × 4 cm |
Based on 0 reviews
Be the first to review “UT 208 CLAMP METER”
-
Multimeters
UT61D+ Digital Multimeter
Specifications Range UT61D+ Safety ratings CAT III 1000V/CAT IV 600V AC voltage (V) 1000V ±(1%+3) DC voltage (V) 1000V ±(0.5%+3) AC current (A) 20A ±(1.2%+5) DC current (A) 20A ±(1%+2) Resistance (Ω) 60MΩ ±(1%+2) Capacitance (F) 60mF ±(3%+5) Frequency (Hz) 10MHz ±(0.1%+4) Duty cycle (%) 0.1%~99.9% ±(2%+5) Temperature (℃/℉) -40℃~1000℃ ±(1%+3) -40℉~1832℉ ±(1%+6) Display count 6000 Bandwidth (Hz) 40Hz~1kHz LoZ ACV √ Peak Hold √ Analog bar 31 General Characteristics Power 1.5V battery (R03) x 4 Product net weight 350g Product size 190mm x 90mm x 50mm Standard accessories Battery, gold plated test leads, USB cable, temperature probe, English manual Standard individual packing Gift box, cloth bag Standard quantity per carton 20pcs Standard carton measurement 480mm x 370mm x 365mm Standard carton gross weight 15.2kg Optional accessories Bluetooth/APP SKU: n/a -
Rework & Soldering Station
YH 862BD+ REWORK STATION
Machine parameter Rated voltage AC 220V±10% 50Hz Total Power 730W±10%(max) 300℃ Constant Temperature Power (High-Speed PID Programmed
to Energy Savings)
250W±10% Operating Environment 0~40℃ Relative humidity<80% Storage temperature -20~80℃ Relative humidity<80% Dimensions 31.5*22*22cm weight 3.5KG Performance Parameter Hot air gun Soldering iron Operating Voltage AC 220V±10% 50Hz AC 26V±10% 50Hz Output power 650W 75W temperature range 100℃~480℃ 200℃~480℃ Air Supply Mode Brushless-Motor Fan — airflow 120L/min(max) — Temperature stability ±2℃ (static) ±2℃ (static) Display Mode Red LED Digital Display Red LED Digital Display Calibration Mode PID Digitally Programmed Calibration
PID Digitally Programmed Calibration
Temperature correction PID digital program proofreading
PID digital program proofreading
SKU: n/a -
Clamp Meters
UT 206B Digital Clamp Meter
Specifications Range UT206B AC current (A) 1000A ±(2%+5) AC current frequency response 50Hz~60Hz Inrush current (A) 1000A ±(10%+10) AC voltage (V) 6V ±(1.2%+3) 60V/600V/1000V ±(1%+8) DC voltage (V) 600mV ±(0.8%+3) 6V/60V ±(0.5%+5) 600V ±(0.5%+5) 1000V ±(0.5%+5) Low pas filter (LPF ACV) 600V/1000V ±(2%+5) AC voltage frequency response 40Hz~400Hz LoZ ACV 600V/1000V ±(2%+5) Resistance (Ω) 600Ω ±(1%+3) 6KΩ/60KΩ/600KΩ ±(1%+2) 6MΩ/60MΩ ±(2%+8) Capacitance (F) 60nF ±(4%+25) 600nF/6μF/60μF/600μF ±(4%+5) 6mF/60mF ±(10%+9) Temperature (℃) -40℃~300℃ ±(1%+20) 300℃~1000℃ ±(1%+2) Low voltage frequency (Hz) 10Hz~1MHz ±(0.1%+3) Duty cycle (%) 10%~90% ±(2.6%+7) Features Display count 6000 Jaw opening 42mm Current frequency 50Hz~60Hz High voltage frequency 40Hz~400Hz Analog bar 31 Auto power off √ Continuity test √ Auto/Manual range √ Low battery indication √ Diode test √ Relative mode/Data hold √ MAX/MIN √ Function selection √ Flashlight √ Wake-up function √ Auto power off current: <50μA √ Flexible current probe (optional) Extends to 3000A √ Input impedance (ACV/DCV) ≥10MΩ √ General Characteristics Power 1.5V battery (R03) x 3 Display 43mm x 45mm Product color Red and grey Product net weight 465g Product size 272mm x 81mm x 43.5mm Standard accessories Test leads, batteries, point contact temperature probe Standard individual packing Gift box, carrying bag, English manual Standard quantity per carton 10pcs Standard carton measurement 355mm x 330mm x 315mm Standard carton gross weight About 7.1kg SKU: n/a -
Wire & Cable Testers
UT18D Voltage and Continuity Tester
1. Auto power off, the conductor to be measured is greater than 12V
2. Phase rotation test3. Continuity test with buzzer and LED indication4. Low battery indication and over voltage prompt5. Flashlight6. Test live voltage without batteries7. Buzzer and silent modes available8. Auto range9. Polarity indicationSKU: n/a -
Clamp Meters
UT-CS09A Flex Clamp Sensor
Specifications Range UT-CS09A AC current (A) 30A/300A/3000A ±(3%+5) Frequency response (Hz) 45Hz~500Hz √ Features Flex clamp size UT-CS09A: 25.4cm (10 inches); UT-CS09C: 45.7cm (18 inches) Operating temperature 0℃~50℃ Storage temperature -20°C~60°C Storage humidity ≤80%RH Low battery indication About 3.3V Range selection Manual General Characterisitics Power 1.5V battery (R03) x 3 Product color Red and grey Product net weight 260g Product size 267mm x 119.4mm x 34mm Standard accessories Batteries, BNC adapter Standard individual packing Blister, English manual Standard quantity per carton 10pcs Standard carton measurement 495mm x 405mm x 225mm Standard carton gross weight 7kg SKU: n/a
There are no reviews yet.