-
Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
The instrument has an electronic overload protection of all functions and ranges.
CMP-2000 Digital clamp-on multimeter
5 in stock
It provides:
- AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
- Measurement of INRUSH current in start-up phase of electrical device.
- AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
- Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω. - Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
₨61,859 ₨65,809
5 in stock
CompareWeight | 0.6 kg |
---|---|
Dimensions | 28 × 11 × 5 cm |
AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
Measurement of INRUSH current in start-up phase of electrical device.
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement
Temperature measurement (Fahrenheit or Celsius).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
- safe, insulated measuring clamp,
- autoranging,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
- „MAX/MIN” function,
- over range indication,
- „AUTO-OFF” function after 30 min.
Electric security:
- measurement category: CAT IV 600 V acc. to EN 61010 – 1,
- protection class acc. to EN 60529: IP20,
Other technical data:
- power supply, 9 V battery type 6LR61,
- display: 6600 counts, backlit LCD,
- continuity test: threshold 30 Ω,
- diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
- low battery indication: BAT displayed,
- over range indication: ‘OL’ displayed,
- temperature sensor: type K thermocouple,
- input impedance: ca.10 MΩ (V DC and V AC),
- AC bandwidth: 50…500 Hz,
- auto power OFF: 30 minutes,
- dimensions: 281 x 108 x 53 mm,
- weight: 570 g (with battery),
- accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.
Rated operational conditions:
- able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
- operating temperature: 0…+50 °C,
- storage temperature: -20…+60 °C,
- operating altitude: max 2000 m.
DC current measurement
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 5 digits) |
660…2000 A | 1 A | ±(3,0% m.v. + 5 digits) for 660…1000 A |
±(5,0% m.v. + 5 digits) for 1000…2000 A |
AC current measurement (TRUE RMS)
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 10 digits) for 50…60 Hz |
±(3,0% m.v. + 10 digits) for 61…400 Hz | ||
660…1500 A | 1 A | ±(2,5% m.v. + 10 digits) for 50…60 Hz i 660…1000 A |
±(3,5% m.v. + 10 digits) for 61…400 Hz and 660…1000 A |
||
±(5,0% m.v. + 10 digits) for 50…400 Hz and 1000…1500 |
DC voltage measurement
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(0,5% m.v. + 2 digits) |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…1000 V | 1 V |
AC voltage measurement (true RMS)
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(1,5% m.v. + 8 digits) for 50…500 Hz |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…750 V | 1 |
Resistance measurement
Range | Resolution | Accuracy |
0,0…659,9 Ω | 0,1 Ω | ±(1,0% m.v. + 5 digits) |
0,660…6,599 kΩ | 0,001 kΩ | |
6,60…65,99 kΩ | 0,01 kΩ | |
66,0…659,9 kΩ | 0,1 kΩ | |
0,660…6,599 MΩ | 0,001 MΩ | ±(2,0% m.v. + 5 digits) |
6,60…66,00 MΩ | 0,01 MΩ | ±(3,5% m.v. + 5 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
0,0…6,599 nF | 0,001 nF | ±(3,0% m.v. + 30 digits) |
6,60…65,99 nF | 0,01 nF | ±(3,0% m.v. + 10 digits) |
66,0…559,9 nF | 0,1 nF | ±(3,0% m.v. + 30 digits) |
6,600…59,999 µF | 0,001 µF | ±(3,0% m.v. + 10 digits) |
66,00…659,99 µF | 0,01 µF | |
660…659,999 µF | 0,100 µF | |
0,660…6,600 mF | 0,001 mF |
Frequency measurement
Range | Resolution | Accuracy |
10…65,99 Hz | 0,01 Hz | ±(0,1% m.v. + 5 digits) |
66,0…659,9 Hz | 0,1 Hz | |
0,660…6,599 kHz | 0,001 kHz | |
6,60…65,99 kHz | 0,01 kHz | |
66,0…659,9 kHz | 0,1 kHz | |
0,660…1,000 MHz | 0,001 MHz |
Temperature measurement
Range | Resolution | Accuracy |
-20…0°C | 1°C | ±(2,0% m.v. + 3°C) |
0…399°C | ±(1,0% m.v. + 2°C) | |
400…1000°C | ±(2,0% m.v. + 3°C) | |
-4…31°F | 1°F | ±(2,0% m.v. + 6°F) |
32..749°F | ±(1,0% m.v. + 4°F) | |
750…1832°F | ±(2,0% m.v. + 6°F) |
Duty cycle measurement
ange | Resolution | Accuracy |
5…95% | 0,1% | ±(2,0% m.v. + 10 digits) |
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMP-2000 Digital clamp-on multimeter”
-
-
PHASE INDICATOR
PHASE INDICATOR KEW 8031
・Two Functions in One Unit
Presence of open phase can be checked by the lamps, and the phase
sequence can be indicated by the rotating disk.・ High Reliability
measuring range for 3-phase installations from 110V to 600V.
Sealed against dust ensures the trouble-free performance.・ Battery-free tester
SKU: n/a -
Clamp Meters
TITAN Clamp Multimeter TN88A in Pakistan
Specifications:
- TITAN TN88A Digital Clamp Meter 500V Insulation Tester
- DC voltage: 1000V ± (0.8% + 2)
- AC voltage: 750V ± (1.2% + 4)
- Alternating current: 200A / 1000A ± (2.5% + 5)
- Resistance: 200Ω / 20kΩ ± (1.0% + 2)
- Insulation test 100kΩ to 2000MΩ (with option 500V insulation tester unit)
- High Resistance: 20MΩ / 2000MΩ ± (5.0% + 2)
- The continuity of the alarm
- Low screen voltage
- Data retention
- Input impedance: 10MΩ
- Sampling rate: 3 times / s
- Maximum display: 1999
- Jaw opening: 50mm
SKU: n/a
There are no reviews yet.