JAKEMY JM-6115 60 in 1 Precision household diy repair tool cr-v ratchet socket screwdriver set
JM-6115 T-Type Labor-Saving And Quick Ratchet Screwdriver Set
Out of stock
ing long nose pliers
Features:
Forward&Reverse with locking action.
T-shaped ratchet screwdriver.
Adjustable screwdriver bits for different screws.
Common uesd in automotive parts and home appliances.
20PCS 40*28mm bright chromium pated bits:
- Slotted: 1.5 2.0 2.5
- Phillips: 1.0 1.5 2.0 2.5 3.0
- Torx: T4 T5 T6 T7 T8
- Hex: H0.9 H1.3 H1.5 H2.0
- Triangle: 2.3
- U-shaped: U2.6
₨2,499 ₨3,291
Out of stock
CompareWeight | 0.7 kg |
---|---|
Dimensions | 12 × 8 × 4 cm |
Specifications:
9PCS inner hexagon sockets:
- M5.0 M6.0 M7.0 M8.0 M9.0 M10 M11 M12 M13
24PCS 6.3*25MM bright chromium plated:
- Slotted: 3.0 4.0 5.0 6.0 7.0
- Phillips: 4.0 5.0 6.5
- Torx: T9 T10 T15 T20 25 T30
- Hex: H2.5 H3.0 H4.0 H5.0 H6.0
- Tri-wing: Y2 Y3
- Pozi: Pz2 Pz3
- U-shaped: U6
1PC H4*120mm adjustable extension bar
1PC H6*150mm adjustable extension bar
1PC T-type ratchet handle
1PC H4 non-slip soft handle
1PC 5″inch nickel plat
Based on 0 reviews
Be the first to review “JM-6115 T-Type Labor-Saving And Quick Ratchet Screwdriver Set”
-
Clamp Meters
Titan Digital Clamp Meter Multimeter Ampere Meter
3 1/2 digits LCD with a Max. Reading of 1999
2) Diode and Buzzer function
3) Low battery indication
4) Overload protection
5) Data hold for easy reading
* Specification:
1) DC voltage: 600V (?1.0%)
2) AC voltage: 450V ( ?1.2% )
3) OHM: 200K? (?1.0%)
4) ACA: 20-400A (?2.0%)
5) Power supply: (AAA) 1.5V?2
6) Data hold: YES
7) Dimension 150L?63W?27.5Hmm
Weight 121g
SKU: n/a -
Insulation Tester
MIC-15k1 ,15kV Insulation Quality Analyzer
Features:
- Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
- It allows testing the electrical durability of the tested object – breakdown voltage indication.
- High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
- The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
- Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
- visual method (if power cables are visible along the entire length),
- reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
- Compatible with external software.