MIC-15k1 ,15kV Insulation Quality Analyzer

Availability:

1 in stock


 

Features:

  • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
  • It allows testing the electrical durability of the tested object – breakdown voltage indication.
  • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
  • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
  • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
    • visual method (if power cables are visible along the entire length),
    • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
  • Compatible with external software.

0

1 in stock

Compare

MIC-15k1 meter is designed to measure insulation resistance of power objects, i.e.:

  • single- and multicore cables,
  • transformers,
  • motors and generators,
  • capacitors, switches and other devices installed in power stations.

It is especially recommended for measurements in areas with very high electromagnetic disturbances, e.g. electrical substations with 1200 kV AC and 500 kV DC. Thanks to the 15 kV measuring voltage (in accordance with ANSI / NETA ATS-2009 TABLES 100.1) the meter can be used for measuring objects with a nominal voltage above 34.5 kV.

Category:
Weight 6.3 kg
Dimensions 39 × 31 × 17 cm

Insulation resistance measurement
Measuring range according to IEC 61557-2
UN = 15 000 V: 50 kΩ…40.0 TΩ
Measurement with DC and increasing voltage (SV) for UISO = 15 kV

Range Resolution Accuracy
0,0…999 kΩ 1 kΩ ±(3% m.v. + 10 digits)
1,00…9,99 MΩ 0,01 MΩ ±(3% m.v. + 10 digits)
10,0…99,9 MΩ 0,1 MΩ ±(3% m.v. + 10 digits)
100…999 MΩ 1 MΩ ±(3% m.v. + 10 digits)
1,00…9,99 GΩ 0,01 GΩ ±(3% m.v. + 10 digits)
10,0…99,9 GΩ 0,1 GΩ ±(3% m.v. + 10 digits)
100…999 GΩ 1 GΩ ±(3,5% m.v. + 10 digits)
1,00…9,99 TΩ 0,01 TΩ ±(7,5% m.v. + 10 digits)
10,0…20,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)
10,0…40,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)

Ranges of measured resistance depending on the test voltage

Voltage UISO Measuring range
50 V 200 GΩ
100 V 400 GΩ
250 V 1,00 TΩ
500 V 2,00 TΩ
1000 V 4,00 TΩ
2500 V 10,00 TΩ
5000 V 20,0 TΩ
10 000 V 40,0 TΩ
15 000 V 40,0 TΩ

Capacitance measurement

Range Resolution Accuracy
0…999 nF 1 nF ±(5% m.v. + 5 digits)
1,00…49,99 µF 0,01 µF ±(5% m.v. + 5 digits)
  • Displaying measured capacity after RISO measurement
  • For measurement voltages below 100 V the measurement error is not specified

Technical specification

  • type of insulation acc. to: EN 61010-1 and IEC 61557 double
  • measurement category acc. to EN 61010-1
    • IV 1000 V (operating altitude ≤2000 m)
    • IV 600 V (operating altitude ≤3000 m)
  • ingress protection acc. to EN 60529: IP67 (IP40 for closed case)
  • resistance to external interference voltages: up to 1550 V
  • resistance to external interference currents: up to 10 mA
  • advanced, digital filtering of interferences: 10 / 30 / 60 / 100 / 200 seconds
  • test leads lock: yes
  • power supply: Li-Ion 14.8 V rechargeable battery from network 90 V ÷ 260 V, 50 Hz/60 Hz
  • dimensions: 390 x 308 x 172 mm
  • weight: approx. 6.3 kg
  • storage temperature: -25ºC…+70ºC
  • operating temperature: -20ºC…+50ºC
  • humidity: 20%…90%
  • operating altitude: ≤3000 m
  • reference temperature: +23ºC ± 2ºC
  • reference humidity: 40%…60%
  • display: graphical LCD
  • number of RISO measurements with battery power supply: min. 1000 acc. to EN 61557-2
  • data transmission: USB and Bluetooth
  • quality standard: ISO 9001 compliant
  • device meets the requirements of standards: EN 61010-1 and IEC 61557
  • the product meets EMC requirements (immunity for industrial environment) with accordance to standards: EN 61326-1 and EN 61326-2-2

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-15k1 ,15kV Insulation Quality Analyzer”

There are no reviews yet.

  • UT12D-US AC Voltage Detector

    0 out of 5
    (0)

    features:
    1. Auto power off
    2. Buzzer
    3. LED indication
    4. AC voltagedetection
    5. High/Low voltagemode

    Applications:
    Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
    High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.

    SKU: n/a
  • LM200C Laser Distance Meters (Discontinued)

    0 out of 5
    (0)

    Features of LM80C/LM120C/LM200C Laser Distance Meters

    ● 2.4-inch color screen

    ● 12 measurement modes
    ● Electronic leveling
    ● 3 selectable measurement references
    ● USB 3.0 supply power
    ● 100 groups of data storage
    ● Rotatable screen
    ● Camera-aided measurement
    ● 2m drop test
    ● IP65 dust and water proof
    SKU: n/a
  • UTG9005C-II Function/Arbitrary Waveform Generato

    0 out of 5
    (0)

    1. Output waveforms: Sine, square, ramp, pulse, noise, DC, arbitrary

    2. Output frequency range: Sine/square, 5MHz
    3. High-accuracy, broad-band 6 bit frequency counter, range: 100mHz~100MHz
    4. 4W power output
    5. EBTN LCD screen
    SKU: n/a
  • UT659A LED testers

    0 out of 5
    (0)

    Features of UT659 Series LED testers

    ● Detect backlight without disassembly

    ● Intelligent adjustment of voltage and current

    ● Test value shown on LCD

    SKU: n/a
  • YH BLACK I TIP

    0 out of 5
    (0)
    SKU: n/a