MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • Fluke 18B+ Digital Multimeter

    0 out of 5
    (0)

    Feature:

    -New Function:Frequency Test

    -New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light

    -Two Mode LED Test :

    -DMM LED Socket Test Mode .

    -UUT(PCBA) LED Test Mode(using test lead).

    -Light up LED without considering the polarity.

    -Voltage,Resistance,Continuity Testing,Capacitance Test.

    -Data Hold,Diode Test.

    -Frequency and Duty Cycle.

    -MAX Input Current 10A.

     

     

    SKU: n/a
  • UT523A Earth Resistance Soil Resistivity Tester

    0 out of 5
    (0)

    UT523A Earth Resistance Soil Resistivity Tester

    SKU: n/a
  • UT33C+ Palm Size Multimeter

    0 out of 5
    (0)

    Main features

    1. Clear LCD display

    2. Equipped with comfortable protective cover, test lead hanging slot

    3. 2m drop proof with precision protection

    4. Auto power off

    5. Auto backlight off

    6. Loud buzzer

    7. Ergonomically designed rotary switch

    SKU: n/a
  • UNI-T UT276A+ Auto Range Digital Clamp Earth Ground Tester

    0 out of 5
    (0)

    ● Auto range
    ● Data hold
    ● Data recall
    ● LCD backlight
    ● Resistance limit alarm
    ● Low battery indication
    ● Auto calibration

    SKU: n/a
  • UT71C Intelligent Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. Can set the interval forauto data recording

    2. MAX/MIN/REL measurement mode

    3. Peak hold

    4. Analogue bar graph

    5. Measure AC and DC in the same stall (AC+DC)

    6. 4-20mA loop test

    7. 45Hz-100kHz frequency response measurement

    8. Double backlight

    9. Misplug alarm

    10. Auto and manual ranges selectable

    11. USB interface available

    12. Bluetooth connection with a cellphone for data monitoring

    13. Temperature measurement mode,equipped with K-type point contact temperature probe

    14. Complies with CE (European Union) and UL (United States) directives

    SKU: n/a