Insulation Resistance Meter
MIC-5001, 5000V Insulation Tester
5 in stock
Insulation resistance measurement in a compact, light-weight, low-cost design.
- Measurement to 5 TΩ
- Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
- Continuous indication of insulation resistance or leakage current
- Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
- Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
- Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
- Continuous display of test voltage during the measurement
- Protection against measuring live objects
- Two and three-lead measurement method
- Ramp Test Insulation resistance measurement
- Measurement of breakdown voltage with increments up to 1 kV / s
- Measurement of alternating and direct voltages from 0 V to 750 V
- 990 cells of memory (11880 records) to record results
- Data transfer to PC via USB cable
- Built-in rechargeable battery pack
- Meets the requirements of the EN 61557 standard
- Charge from optional car lighter (12 V) socket accessory
₨0
5 in stock
CompareWeight | 1 kg |
---|---|
Dimensions | 20 × 18 × 8 cm |
Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)
Range | Resolution | Accuracy |
---|---|---|
0.0 to 999.9 kΩ | 0.1 kΩ | ±(3% m.v. + 20 digits) |
1.000 to 9.999 MΩ | 0.001 MΩ | ±(3% m.v. + 20 digits) |
10.00 to 99.99 MΩ | 0.01 MΩ | ±(3% m.v. + 20 digits) |
100.0 to 999.9 MΩ | 0.1 MΩ | ±(3% m.v. + 20 digits) |
1.000 to 9.999 GΩ | 0.001 GΩ | ±(3% m.v. + 20 digits) |
10.00 to 99.99 GΩ | 0.01 GΩ | ±(3% m.v. + 20 digits) |
100.0 to 999.9 GΩ | 0.1 GΩ | ±(3% m.v. + 20 digits) |
1.000 to 5.000 TΩ | 1 GΩ | ±(4% m.v. + 50 digits) |
Values of measured resistance depending on measurement voltage
Voltage VISO | Measurement range |
---|---|
up to 100 V | 50 GΩ |
200 to 400 V | 100 GΩ |
500 to 900 V | 250 GΩ |
1000 to 2400 V | 500 GΩ |
2500 V | 2500 GΩ |
5000 V | 5 TΩ |
RampTest Insulation resistance measurement
Range | Resolution | Accuracy |
---|---|---|
0.0 to 999.9 kΩ | 0.1 kΩ | ±(5% m.v. + 40 digits) |
1.000 to 9.999 MΩ | 0.001 MΩ | ±(5% m.v. + 40 digits) |
10.00 to 99.99 MΩ | 0.01 MΩ | ±(5% m.v. + 40 digits) |
100.0 to 999.9 MΩ | 0.1 MΩ | ±(5% m.v. + 40 digits) |
1.000 to 9.999 GΩ | 0.001 GΩ | ±(5% m.v. + 40 digits) |
10.00 to 99.99 GΩ | 0.01 GΩ | ±(5% m.v. + 40 digits) |
100.0 to 999.9 GΩ | 0.1 GΩ | ±(5% m.v. + 40 digits) |
1.000 to 4.999 TΩ | 0.001 TΩ | ±(5% m.v. + 40 digits) |
The measurement of breakdown voltage in RampTest mode
Range | Resolution | Chosen UISO | Accuracy |
---|---|---|---|
25.0 V to 99.0 V | 0.1 V | <600 V | ± 5% m.v. ± 10 digits |
100 V to 600 V | 1 V | <600 V | ± 5% m.v. ± 4 digits |
25 V to 999 V | 1 V | >600 V | ± 5% m.v. ± 5 digits |
1.00 kV to 5.00 kV | 10V | >600 V | ± 5% m.v. ± 4 digits |
DC and AC voltage measurement
Range | Resolution | Accuracy |
---|---|---|
0 to 299.9 V | 0.1 V | ±(3% m.v. + 2 digits) |
300 to 750 V | 1 V | ±(3% m.v. + 2 digits) |
- frequency range: 45 to 65 Hz
VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”
Electrical safety:
- type of insulation double, in acc. with EN 61010-1 and IEC 61557
- measurement category III 600 V (IV 300 V) in acc. EN 61010-1
- case protection rating in acc. EN 60529 IP6529: IP65
Other technical specifications::
- power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
- weight of the meter approx. 0.9 kg, 2 lbs
- dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
- LCD segment display
- memory for measurement results: 990 cells, 11880 records
- transfer of measurement results data via USB
Based on 0 reviews
Be the first to review “MIC-5001, 5000V Insulation Tester”
-
Clamp Meters
MT87 3 1/2 Digits LCD Digital Clamp Meter
This meter features a portable design, 31/2 LCD display and 25mm jaw opening, which can provides various measurements for AC/DC voltage, AC current, resistance, diode and continuity buzzer. It is also with functions of date hold, low battery indication, overload indication, etc. More detailed product information, please refer to the English manual.
SKU: MT 87 CLAMP METER -
Clamp Meters
UT216B 600A True RMS Digital Clamp Meters
UT216 series true RMS digital clamp meter is a new-generation practical electrotechnical measurement meter which has the features of high reliability, high safety, automatic range and handheld type, has full-range overload protection and unique appearance design, is more excellent in performance, and is an ideal tool for detection, maintenance and repair of various universities and colleges, smelting, communication, manufacturing, petroleum, national defense, electrical, power and circuit equipment.
UTD216B (main features)- 1、600A AC current measurement;
- 2、True RMS response for ACV and ACA;
- 3、99.99mF capacitance measurement;
- 4、V.F.C function for measuring signal at variable frequency ;
- 5、Non-contact voltage detection with LED indication;
- 6、Flashlight for working at dark environment.
SKU: n/a -
Oscilloscopes
UTD1050DL Handheld Digital Storage Oscilloscopes
Product Features:
1、 Fully Auto Scale; Vertical Scale and Timebase automatically adjusted with the signal and without any manual interference;
2、 Unique and powerful Auto Setup, quick and accurate to set up for signals with any DC component;
3、 Wider voltage measuring range; Coupled with 10×probe with attenuation up to 200V/div;
4、 Isolated USB for much safer communication;
5、 White and black display for your option, perfect for use outdoors with strong light;
6、 Intelligent local or network software update;
7、 More than 6 hours of continuous battery operation.SKU: n/a
There are no reviews yet.