MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • UT309A Professional Infrared Thermometer

    0 out of 5
    (0)

    Features

    1. 3m drop proof, IP65

    2. Large LED display with backlight

    3. MAX/MIN/AVG/DIF mode

    4. High/Low temperature alarm with LED indication

    5. Lock measurement

    6. Data hold/auto power off function

    SKU: n/a
  • UT-CS09D Flex Clamp Sensor

    0 out of 5
    (0)

    Features of UT-CS09D Flex Clamp Sensor

    Certificates: CE, UKCA, cETLus

    ● Flex clamp can measure from 1.5A to 3000A current

    ● 1m drop proof
    ● Robust terminal connection
    ● Directly displays current when connected to UT206B/208B
    SKU: n/a
  • CMM-10 Multimeter

    0 out of 5
    (0)
    • Autoranging/manual range selection.
    • DATA HOLD function, for holding measured values.
    • REL function, which allows you to make measurements relative to a stored reference value.
    • Continuity test with acoustic signalling (beeper).
    • AUTO-OFF function.
    • Display 3 7/8 digits (5000 max).
    SKU: n/a
  • UT60S

    0 out of 5
    (0)
    1. 9999 counts
    2. True RMS
    3. Bluetooth
    4. Duty cycle
    5. Diode/Continuity test
    6. Temperature
    7. Non-contact voltage
    8. Analog bar/Data hold
    9. Backlight/Relative mode
    10. Auto/Manual range
    11. Low battery indication
    12. Three-color LED light indicator
    SKU: n/a
  • UT58C General Digital Multimeter

    0 out of 5
    (0)

    1. 2000 display count, refresh rate 2~3 times/s

    2. Function symbols and test lead connection indication
    3. Transistor measurement
    4. Temperature measurement mode, with K-type temperature probe
    5. Frequency measurement
    6. Diode and continuity buzzer; auto power off; overload protection
    7. Data hold; 20A AC/DC current measurement
    SKU: n/a
  • Fluke 17B+ Digital Multimeter

    0 out of 5
    (0)

    Key features

    • 600 V Cat III safety rating
    • 50% bigger display with bright white backlight
    • Over-voltage indicator
    • Frequency and temperature measurement
    • Voltage, resistance, continuity, capacitance
    • Input terminal for ac and dc current measurements to 10 A current
    • Diode test, data hold
    SKU: n/a