The UT725 multifunction process calibrator combines with temperature process calibrator and loop process calibrator function. You can easily measure and source most of the process parameter: mA, volts, temperature, frequency, ohms in one tool.
Specifications of UT725 Multifunction Process Calibrator
Specifications | Range | UT725 |
Measurement | ||
DC voltage (V) | 50mV/500mV/50V | ±(0.02%+2) |
DC current (mA) | 20mA | ±(0.02%+2) |
Loop current (mA) | 20mA | ±(0.02%+2) |
Resistance (Ω) | 500Ω/5000Ω | ±(0.05%+10) |
Frequency (Hz) | 100Hz/1kHz/10kHz/100kHz | ±(0.01%+1) |
Thermocouples | R,S,K,E,J,T,N,B,L,U,XK,BP | |
RTDs | Pt100/Pt200/Pt500/Pt1000/Cu10/Cu50/Cu100/Pt100-392/Pt100-JIS/Ni120 | |
Continuity test | √ | |
Pulses (Hz) | 1~15kHz (1~100000 periods) | |
Source accuracy | ||
DC voltage (V) | 100mV/1000mV/10V | ±(0.02%+10) |
DC current (A) | 20mA/20mA(SIM) | ±(0.02%+2) |
Resistance (Ω) | 400Ω/4000Ω/40kΩ | ±(0.05%+10) |
Frequency (Hz) | 200Hz/2000Hz/20kHz/100kHz | ±(0.01%+1) |
Pulses (Hz) | 100Hz/1kHz/10kHz | ±1 |
Thermocouples | R,S,K,E,J,T,N,B,L,U,XK,BP | |
RTDs | Pt100-385/Pt100-392/Pt100-JIS/Pt200-385/P500-385/Pt1000-385/Cu10/Cu50/Cu100/Ni120 | |
Display count | 20000 | |
Operation temperature | -10°C~55°C | |
General Characteristics | ||
Power | 1.2V x 6 AA rechargeable battery | |
Product net weight | 650g | |
Product size | 195mm x 95mm x 58mm | |
Standard accessory | Test lead, USB cable, power adapter, temperature probe, English manual |
Based on 0 reviews
Be the first to review “UT725 Multifunction Process Calibrator”
-
Clamp Meters
CLAMP METER AC CM 2030
Features
. Digital clamp meter 266 opens 52mm.
2. Large LCD display makes reading clear.
3. Full function protection, strong anti-interferential performance.
4. CE standard design, improves the safety of the test.
5. Data hold.
6. Clamp light and backlight display.
SKU: n/a -
Oscilloscopes
UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a
There are no reviews yet.