Product Features
1. Analogue bar graph
2. Diode test and buzzer continuity
3. Transistor measurement
4. Auto range
5. MAX/MIN/REL measurement mode
Out of stock
Product Features
1. Analogue bar graph
2. Diode test and buzzer continuity
3. Transistor measurement
4. Auto range
5. MAX/MIN/REL measurement mode
₨5,842 ₨6,318
Out of stock
CompareProduct Features
1. Analogue bar graph
2. Diode test and buzzer continuity
3. Transistor measurement
4. Auto range
5. MAX/MIN/REL measurement mode
Specifications | Range | Best Accuracy |
Model | UT60A | |
DC Voltage (V) | 400mV/4V/40V/400V/1000V | ±(0.8%+1) |
AC Voltage (V) | 4V/40V/400V/750V | ±(1%+5) |
Communication bandwidth | 40Hz~400Hz | √ |
DC Current (A) | 400mA/4000mA/40mA/400mA/4A/10A | ±(1%+2) |
AC Current (A) | 400mA/4000mA/40mA/400mA/4A/10A | ±(1.5%+5) |
Resistance (Ω) | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | ±(1%+2) |
Capacitance (F) | 40nF/400nF/4μF/40μF/100μF | ±(3%+5) |
Frequency (Hz) | 10Hz~9MHz | ±(0.1%+3) |
Duty Cycle | 0.1%~99.9% | √ |
Features | ||
Fused 10A Range | Ceramic fuse | √ |
Relative Mode | √ | |
Full Icon Display | √ | |
Diode | √ | |
Continuity Buzzer | √ | |
Low Battery Display | √ | |
Input Impedance for DC Voltage Measurement | 10MΩ | √ |
Data Hold | √ | |
Auto Ranging | √ | |
Auto/Manual Range | √ | |
Display Backlight | √ | |
Max Display | 3999 | √ |
Auto Power Off | √ | |
General Characteristic | ||
Power | 9V Battery (6F22) | |
LCD Size | 63mm×31mm | |
Product Colour | Red and Grey | |
Product Net Weight | 340g | |
Product Size | 177mm×85mm×40mm | |
Standard Accessories | Test Lead, Battery,Test Clip, RS232C Interface Cable,PC Software CD | |
Standard Individual Packing | Gift Box, English Manual | |
Standard Quantity Per Carton | 40Pcs | |
Standard Carton Measurement | 595mm x 400mm x 326mm (0.078 CBM Per Standard Carton) | |
Standard Carton Gross Weight | 21Kg | |
Optional Accessories* | Clip-On Test Lead Light (UT-TL), Built-In Test Lead Light (UT-L1), Built-In Test Lead Light Plus (UT-L2) |
UT510 series is a kind of intelligent insulation tester. The device circuit design takes microcomputer technology design as the core and combines the large scale integrated circuit with digit circuit. It is equipped with strong measuring software and data processing software. It is applied to the parameter measurement of insulation resistance, voltage and low resistance. It has stable performance and simple operation. It is applicable to on-site measurement and repair of the electrical equipment and charging line. It is the ideal tool of maintaining electrical equipment. It is also used for smelting, communication, manufacture, fossil oil, national defense, electricity, chemical industry and circuit.
Analog bandwidth | 150MHz | 250MHz | ||
Channels | 2+16 digital | 4+16 digital | 2+16 digital | 4+ 16digital |
Sampling rate (Analog) | 2.5GS/s (Single channel), 1.25GS/s (Dual channels) | |||
Sampling rate (Digital) | 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) | |||
Memory depth | 70Mpts | |||
Waveform capture rate | 200,000wfms/s | |||
Time base scale | 2ns/div~50s/div (Real-time sampling rate, memory depth display ) | |||
Time base scale (digital) | 2ns/div~40S/div[Step by 1-2-4 stall] | |||
Input impedance | (1MΩ±1%) II (20pF±3pF) | |||
Input impedance digital | (101kΩ±1%) II (9pF±1pF) | |||
Vertical scale | 1mV/div~20 V/div (1 MΩ) | |||
DC gain accuracy | <5mV: ±3%, ≥5mV: ±2% | |||
Waveform record | 100,000 frames | |||
Trigger types | Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay |
|||
Bus decode | RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay | |||
Waveform operations | A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations | |||
Auto measurements |
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A |
|||
Measurement display | 5 types | |||
Measurement statistics | Average, Max, Min, standard deviation and number of measurements | |||
Frequency counter | 6 bits | |||
Standard interfaces | USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA | |||
Standard Accessories |
USB interface cable | UT-D14 | ||
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) | UT-P06 | |||
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) | UT-P05 | |||
16CH Logic analyzer probe | UT-15M |
Main Features
1. Sampling time: 10s
2. Clock function: 12/24 hour mode
3. Alarm function: Rings up to 60s
4. Temperature measurement + Humidity measurement+ Time
5. Temperature testing range: -10℃~50℃(14℉~122℉); Accuracy: ±1℃(±1.8℉)
6. Humidity testing range: 10~99%RH; Precision: ±5%RH
7. Environmental comfort rating: Comfort, wet, dry
UT387 series wall scanners are great tools designed for construction and home improvement sector. These scanners can pick up hidden objects behind walls, such as metals, live electrical wires, and wood. UT387A is designed for dry wall, but it can also effectively scan hardwood flooring, plywood, and coated wooden walls. It has two scanning modes, these are used for scanning walls of different thickness.
There are no reviews yet.