-1%

UT 206B Digital Clamp Meter

Availability:

10 in stock


Specifications Range UT206B
AC current (A) 1000A ±(2%+5)
AC current frequency response 50Hz~60Hz
Inrush current (A) 1000A ±(10%+10)
AC voltage (V) 6V ±(1.2%+3)
60V/600V/1000V ±(1%+8)
DC voltage (V) 600mV ±(0.8%+3)
6V/60V ±(0.5%+5)
600V ±(0.5%+5)
1000V ±(0.5%+5)
Low pas filter (LPF ACV) 600V/1000V ±(2%+5)
AC voltage frequency response 40Hz~400Hz
LoZ ACV 600V/1000V ±(2%+5)
Resistance (Ω) 600Ω ±(1%+3)
6KΩ/60KΩ/600KΩ ±(1%+2)
6MΩ/60MΩ ±(2%+8)
Capacitance (F) 60nF ±(4%+25)
600nF/6μF/60μF/600μF ±(4%+5)
6mF/60mF ±(10%+9)
Temperature (℃) -40℃~300℃ ±(1%+20)
300℃~1000℃ ±(1%+2)
Low voltage frequency (Hz) 10Hz~1MHz ±(0.1%+3)
Duty cycle (%) 10%~90% ±(2.6%+7)
Features
Display count 6000
Jaw opening 42mm
Current frequency 50Hz~60Hz
High voltage frequency 40Hz~400Hz
Analog bar 31
Auto power off
Continuity test
Auto/Manual range
Low battery indication
Diode test
Relative mode/Data hold
MAX/MIN
Function selection
Flashlight
Wake-up function
Auto power off current: <50μA
Flexible current probe (optional) Extends to 3000A
Input impedance (ACV/DCV) ≥10MΩ
General Characteristics
Power 1.5V battery (R03) x 3
Display 43mm x 45mm
Product color Red and grey
Product net weight 465g
Product size 272mm x 81mm x 43.5mm
Standard accessories Test leads, batteries, point contact temperature probe
Standard individual packing Gift box, carrying bag, English manual
Standard quantity per carton 10pcs
Standard carton measurement 355mm x 330mm x 315mm
Standard carton gross weight About 7.1kg

16,800 16,895

10 in stock

Compare

UT200 series are 6000-count digital clamp meters with auto range, large LCD, true RMS, auto scale memory, and NCV functions. They conform to CAT III 1000V/CAT IV 600V safety rating and certified by CE/ETL. The UT206B, UT207B, and UT208B come with LoZ mode for eliminating ‘ghost ’voltage, LPF ACV function for measuring INV and VFD voltage, and inrush current mode for capturing transient current. The UT206B and UT208B also feature high-precision temperature measurement with 0.1 °C resolution, and can be equipped with a flexible current probe to extend the AC current measurement range to 3000A.

1. Flashlight button: Short press this button to turn on/off the flashlight.

2. Flexible current probe (optional) to extend the AC current measurement range to3000A
3. Inrush current capture
4. NCV Multi-Segment Display and audio/visual alarm
5. True RMS/Auto backlight
6. NCV/Function retention
Category:
Weight 0.45 kg
Dimensions 27 × 8 × 4 cm

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT 206B Digital Clamp Meter”

There are no reviews yet.

  • UTD 07A Bluetooth Adaptor

    0 out of 5
    (0)

    ● Description: Bluetooth 4.0 communication protocol                                                                                                           ● Support: iOS 6.0 or above, Android 4.0 or above                                                                                                                 ● Application: UT71、UT171、UT181 series                                                                                                                               ● Power: 1.5V battery (R03) x 2

    SKU: n/a
  • UT L33 Insulation Meter Lead

    0 out of 5
    (0)

    ● Combinations: combined with 1PCS (red+ black) alligator clip test leads and 1PCS double-plug alligator clip test leads

    ● Material: Double insulated UL authenticated material
    ● Total length: 1200±20mm
    ● Safety level: C
    SKU: n/a
  • UT 205E 1000A True RMS Digital Clamp Meter

    0 out of 5
    (0)
    Specifications Range UT205E
    AC current (A) 1000A ±(2%+5)
    AC current frequency response 50Hz~60Hz
    AC voltage (V) 6V ±(1.2%+3)
    60V/600V/1000V ±(1%+8)
    DC voltage (V) 600mV ±(0.8%+3)
    6V/60V ±(0.5%+5)
    600V ±(0.5%+5)
    1000V ±(0.5%+5)
    AC voltage frequency response 40Hz~400Hz
    Resistance (Ω) 600Ω ±(1%+3)
    6KΩ/60KΩ/600KΩ ±(1%+2)
    6MΩ/60MΩ ±(2%+8)
    Capacitance (F) 60nF ±(4%+25)
    600nF/6μF/60μF/600μF ±(4%+5)
    6mF/60mF ±(10%+9)
    Low voltage frequency (Hz) 10Hz~1MHz ±(0.1%+3)
    Duty cycle (%) 10%~90% ±(2.6%+7)
    Features
    Display count 6000
    Jaw opening 42mm
    Current frequency 50Hz~60Hz
    High voltage frequency 40Hz~400Hz
    Auto power off
    Continuity test
    Auto/Manual range
    Low battery indication
    Diode test
    Relative mode/Data hold
    MAX/MIN
    Function selection
    Flashlight
    Wake-up function
    Auto power off current: <50μA
    Input impedance (ACV/DCV) ≥10MΩ
    General Characteristics
    Power 1.5V battery (R03) x 3
    Display 43mm x 45mm
    Product color Red and grey
    Product net weight 465g
    Product size 272mm x 81mm x 43.5mm
    Standard accessories Test leads, batteries, point contact temperature probe
    Standard individual packing Gift box, carrying bag, English manual
    Standard quantity per carton 10pcs
    Standard carton measurement 355mm x 330mm x 315mm
    Standard carton gross weight About 7.1kg
    SKU: n/a
  • UT 207 CLAMP METER

    0 out of 5
    (0)

    1. 1000A AC/DC current measurement, 3 times/s sampling rate                                                                                       2. True RMS                                                                                                                                                                                 3. Inrush current                                                                                                                                                                         4. Zeroing function                                                                                                                                                                     5. Full icon display                                                                                                                                                                     6. MAX/MIN                                                                                                                                                                               7. Data hold; Duty cycle                                                                                                                                                             8. Auto power off and low battery indication                                                                                                                         9. Diode; Continuity buzzer; Input Impedance for DCV

    SKU: n/a
  • YH 939D+ SOLDERING STATION

    0 out of 5
    (0)
    PARAMETROS
    MODEL 939D+
    RATED VOLTAGE AC 220V±10%  50Hz
    OUTPUT POWER 75W
    Constant Temperature Power (High-Speed PID Programmed to Energy Savings) 200W±10%
    Withstand voltage and insulation tests AC1500V 0.4A 60S
    Operating Environment 0~40℃  relative humidity<80%
    Storage environment -20~80℃  relative humidity<80%
    Body size 14.5*12*8CM
    Weight 2.17KG
    Work voltage AC 26V±10%  50Hz
    Temperature range 200℃~480℃
    Temperature Stability ±1℃(Static)
    Display Mode LED Digital Display
    Calibration Mode PID Digitally Programmed Calibration
    PID Temperature Calibration Cycle 100MS
    Heating Core Imported High-Powered Heating Core
    Tip-to-Ground Impedance <2Ω
    Tip-to-Ground Voltage <2mV
    SKU: n/a
  • UT18D Voltage and Continuity Tester

    0 out of 5
    (0)

    1. Auto power off, the conductor to be measured is greater than 12V

    2. Phase rotation test
    3. Continuity test with buzzer and LED indication
    4. Low battery indication and over voltage prompt
    5. Flashlight
    6. Test live voltage without batteries
    7. Buzzer and silent modes available
    8. Auto range
    9. Polarity indication
    SKU: n/a