- UT-219 professional clamp meter series is three-proofing digital clamp meter specially designed for professional industrial users.
- The industrial design of this series is rugged and durable, and capable of withstanding the impact from 2 meters fall-down.
- The waterproof rating is up to IP54; therefore, it can be used in environment with water splashing or much more dust.
- The whole series is configured with LoZ (Low Impedance Input) AC voltage tap position, which is capable of testing the false voltage; auto backlight function can be used continuously under the circumstance of emergency power outage.
- UT-219DS is also provided with MOTOR test function, allowing to directly test the phase sequence of three phase AC motor by means of the probe. UT-219 series is much more in compliance with CAT IV 600V safety level, and certified by the German GS institution.
UT219DS ACA DCA Professional Clamp Meters with Motor LPF Test
9 in stock
- UT-219 professional clamp meter series is three-proofing digital clamp meter specially designed for professional industrial users.
- The industrial design of this series is rugged and durable, and capable of withstanding the impact from 2 meters fall-down.
- The waterproof rating is up to IP54; therefore, it can be used in environment with water splashing or much more dust.
- The whole series is configured with LoZ (Low Impedance Input) AC voltage tap position, which is capable of testing the false voltage; auto backlight function can be used continuously under the circumstance of emergency power outage.
- UT-219DS is also provided with MOTOR test function, allowing to directly test the phase sequence of three phase AC motor by means of the probe. UT-219 series is much more in compliance with CAT IV 600V safety level, and certified by the German GS institution.
₨38,400 ₨40,240
9 in stock
CompareWeight | 0.3 kg |
---|---|
Dimensions | 24 × 8 × 5 cm |
SPECIFICATION
Safety Rating: CAT IV 600V
Display Count: 6000
DC Voltage (V): 600.0V
AC Voltage: 600.0V
LoZ ACV: 600.0V
DC Current (A): 600.0A
AC Current (A): 600.0A
Resistance (Ω): 60.00MΩ
Capacitance (F): 60.00mF
DC Current: 2000uA
AC Current: 2000uA
Frequency (Hz): 40.00MHz
Diode Test/Continuity Buzzer
Duty Cycle
Temperature (°C/°F)
Motor Test: three phase rotation test can identify the phases of the power supply
LPF (1kHz 3dB decay)
Inrush Current
AC+DC Voltage (V)
Dual-Display (Voltage+Current)
Backlight
Integrated Protection Level: IP54
Application: HVAC/R Motor
Power supply: AAA 1.5V alkaline battery × 3
Product Dimensions : (L x W x H)
8cm x 4.5cm x 23cm
Product Weight: 0.31 kg
Based on 0 reviews
Be the first to review “UT219DS ACA DCA Professional Clamp Meters with Motor LPF Test”
-
Voltage Detector
UT12M-US AC Voltage Detector
features:
1. Auto power off
2. Buzzer
3. LED indication
4. IP 67
5. AC voltagedetection
6. High/Lowvoltage mode
7. Magnetic solenoiddetectionApplications:
Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.SKU: n/a -
Clamp Meters
UT281A True RMS AC 3000A Flexible Clamp Meters
1. 2m drop proof, IP54, ETL/Intertek certified 3rd edition CE
2. Coil diameter: 0.75cm, bending length: 24.5cm for UT281A and 45.7cm for UT281C
3. Large LCD display for clear reading
4. True RMS
5. Long press INRUSH key for 2s to measure inrush current
6. Data hold, backlight, auto power off
SKU: n/a -
Oscilloscopes
UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
There are no reviews yet.