-6%

UT221 2000A ACA DCA Digital Clamp Meters

Availability:

10 in stock


UT221 are stable and safe 3 5/6 digit AC&DC digital clamp meters.It is perfectly designed with over-load protection for all ranges and the unique structure, making it a superb professional meter especially for electricians.
An ideal tool for the maintenance and troubleshooting needed in metallurgy, manufacturing, petroleum, electric power, chemical industry, etc;

42,000 44,690

10 in stock

Compare

UT221 are stable and safe 3 5/6 digit AC&DC digital clamp meters.It is perfectly designed with over-load protection for all ranges and the unique structure, making it a superb professional meter especially for electricians.
An ideal tool for the maintenance and troubleshooting needed in metallurgy, manufacturing, petroleum, electric power, chemical industry, etc;

Category:
Weight 0.7 kg
Dimensions 30 × 11 × 5 cm
Specifications Range Best Accuracy
Model UT221
AC Current(A) 660A/2000A ±(2.5%+5)
DC Current(A) 660A/2000A ±(2.5%+5)
AC Voltage(V) 6.6V/66V/660V/750V ± (1.2%+5)
DC Voltage(V) 6.6V/66V/660V/750V ±(0.8%+1)
Resistance(Ω) 660Ω/6.6kΩ/66kΩ/660kΩ/6.6MΩ/66MΩ ±(1.0%+2)
Frequency(Hz) 66Hz/660Hz/6.6kHz/66kHz/660kHz/6.6MHz/20MHz ±(0.1%+3)
Features
Display Count 6600
Auto Range
Jaw Opening 63mm
True RMS AC Voltage/AC Current
Duty Cycle 0.1%~99.9%
Diode
Continuity Buzzer
Low-Pass Filtering
Inrush Current AC Current
Relative Function
Data Hold
MAX
MAX/MIN
LCD Backlight
Analogue Bar Analogue 66
Full Icon Display
Auto Power Off
Low Battery Indication
Input Impedance ≥10MΩ
I-OUT Function
General Characteristics
Power 9V Alkaline Battery(6LF22)
LCD Size 43mm×30 mm
Product Color Red and Grey
Product Net Weight 725g
Product Size 298mm × 100mm × 48mm
Standard Accessaries Test Leads, Output Cable,Tool Box
 Standard Individual Packing Gift box, English Manual
Standard Quantity Per Carton 5PCs
Standard Carton Measurement 510mm×375mm×320mm
Standard Carton Gross Weight 12Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT221 2000A ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • UT70D Modern Digital Multi-Purpose Meters

    0 out of 5
    (0)

    Portable digital multimeter UNIT UT70D with advanced design. Photoelectric separation guarentees absolutely secure galvanic isolation of multimeter from PC.LCD (79999), bargraph; I DC:80m/800m/8/10A. … frequency, AC voltage, DC voltage, capacitance, AC current, DC current, resistance. … DC voltage measuring range.

    SKU: n/a
  • UT285C Three Phase Power Quality Analyzer

    0 out of 5
    (0)

    1. Waveform real-time display (4 channels voltage/4 channels current).

    2. True RMS values of voltages and currents
    3. Peak current and voltage values
    4. Total harmonic distortion (THD)
    5. Active, reactive, apparent power, by phase and cumulative
    6. Transformer K factor
    7. Power factors (PF) and displacement factors (DPF or COSΦ)
    8. Short-term voltage flicker (PST)
    9. Three phase unbalance(current and voltage)
    10. USB interface/PC software
    SKU: n/a
  • YH ELEMENT FOR 948D

    0 out of 5
    (0)
    SKU: n/a
  • UNI T Benchtop Digital Multimeter UT8802E

    0 out of 5
    (0)
    1. 20,000 Count EBTN LCD Display
    2. DC Voltage: 200mV/2V/20V/200V/1000V
    3. AC Voltage: 2V/20V/200V/750V
    4. DC Current: 200μA/2mA/20mA/200mA/20A
    5. AC Current: 2mA/20mA/200mA/20A
    6. Resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200MΩ
    7. Capacitance: 20nF/200nF/2μF/20μF/200μF/2mF/20mF/100mF
    8. Frequency: 200Hz~10MHz
    9. Duty cycle: 5%~99%
    10. Frequency response: 1 kHz
    11. USB Interface
    12. Data hold
    13. MAX/MIN
    14. Continuity buzzer
    15. Diode/transistor
    16. test
    17. CAT II 600V
    SKU: n/a
  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a
  • UT601 Inductance Capacitance Meters

    0 out of 5
    (0)

    UT600 series RCL meter is a kind of 3.5-bithandheld digital meter with stable performance, safety, reliability, highaccuracy and manual range. It can be used to measure the magnification times β of audion, diode forward voltage drop and circuit continuity. UT601has wide capacitance measurement range from 0.1pF~20mF and highaccuracy. UT602 can hold data. UT 600 series is applicable to testingresistance, capacitance and inductance of electronic laboratory, productionline, maintenance point and teaching. It is the ideal tool of maintaining formany users

    SKU: n/a