Insulation Tester
UT502A Insulation Resistance Tester
Availability:
Out of stock
1. 2000 count LCD display, overload indication, backlight
2. AC voltage measurement, auto power off
3. Auto discharge
4. Continuous measurements mode, red warning light and buzzer function
5. Continuous low resistance measurement
6. PI and DAR measurement, auto resistivity calculation
7. Low resistance returning to zero function to improve accuracy
₨24,852 ₨30,793
Out of stock
CompareUT500 series insulation testers are used to measure the insulation resistance of electrical equipment and household appliances. This is done by measuring the insulation resistance between electrical circuits or between circuits and ground. UT500 series can measure insulation resistance, AC Voltage, low resistance, PI (Polarization Index) and DAR (Dielectric Absorption). These are dieal tools for ensuring transformers, genera-tors, high voltage motors, power capacitors, power cbles, arresters and other electrical equipment that can oprate in a safe and accurate manner.
Applications:
It is used for insulation resistance measurement for insulation materials and various kinds of electric equipments such as transformer, electric machines, cables, switches, electrical appliance, a ideal tool for electric maintenance, testing and inspection.
Weight | 0.5 kg |
---|---|
Dimensions | 15 × 10 × 7 cm |
Specifications | Range | UT502A | |
Insulation resistance (Ω) | Test voltages | 500V/1000V/2500V | 0%~10% |
500V | 0MΩ~99.9MΩ | ±(3%+5) | |
100MΩ~5GΩ | ±(5%+5) | ||
1000V | 0MΩ~99.9MΩ | ±(3%+5) | |
100MΩ~5GΩ | ±(5%+5) | ||
2500V | 0MΩ~99.9MΩ | ±(3%+5) | |
100MΩ~9.9GΩ | ±(5%+5) | ||
10GΩ~20GΩ | ±(10%+5) | ||
Load current | 50V (R=50kΩ) 1mA | 0%~10% | |
100V (R=100kΩ) 1mA | 0%~10% | ||
250V (R=250kΩ) 1mA | 0%~10% | ||
500V (R=500kΩ) 1mA | 0%~10% | ||
1000V (R=1MΩ) 1mA | 0%~10% | ||
2500V (R=1MΩ) 1mA | 0%~10% | ||
Short-circuit current | <2mA | ||
Low resistance (Ω) | 0.01Ω~200Ω (about 5.0V/>200mA) | ±(2%+3) | |
AC voltage (V) | 30V~600V | ±(2%+3) | |
Features | |||
Display count | 2000 | ||
DAR | 60s/15s and 60s/30s | √ | |
PI | √ | ||
Auto range/Low battery indication | √ | ||
LCD backlight/Light alarm | √ | ||
Buzzer alarm/High voltage indication | √ | ||
Over load indication/Auto discharge | √ | ||
Test voltage secondary display | √ | ||
10MΩ internal resistance test | √ | ||
Meets IEC 61557 | 61557-1:2007; 61557-2:2007; 61557-4:2007 | ||
General Characterisitics | |||
Power | 1.5V battery (LR6) x 6 | ||
Display | 70.6mm x 34mm | ||
Product color | Red and grey | ||
Product net weight | 500g | ||
Product size | 150mm x 100mm x 71mm | ||
Standard accessories | Batteries, test leads, alligator clips, gallus, test probes | ||
Standard individual packing | Gift box, carrying bag, English manual | ||
Standard quantity per carton | 20pcs | ||
Standard carton measurement | 500mm x 380mm x 330mm (0.063 CBM per standard carton) | ||
Standard carton gross weight | 18.9kg |
Based on 0 reviews
Be the first to review “UT502A Insulation Resistance Tester”
-
Laser Distance Meters
LM150 Laser Distance Meter
1. Ergonomic exterior, comfortable handling
2. Millimeter accuracy3. Large, multiple angle HD display5. Physical and electronics leveler6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more7. Auto power off after 3 minutes without operationSKU: n/a -
Digital Radiation Tester
Digital Radiation Tester ET825 Handheld Electric and Magnetic Field Radiation Detector with Sound and Light Alarm
Digital Radiation TesterDigital Radiation Tester ET825 Handheld Electric and Magnetic Field Radiation Detector with Sound and Light Alarm
Model: ET825
Material: ABS
Power Supply: 3xAAA 1.5V Battery (Battery Not Included)
Application: It is suitable for electromagnetic radiation testing.
Monitoring Places: It can detect radiation in homes, offices, outdoors, and industrial places.
Testing Items: It can perform radiation testing on mobile phones, computers, TVs, refrigerators, and high-voltage lines.
Radiation Protection Products Inspection: it can test the effects of radiation protection clothing, radiation protection films and other protective equipment.SKU: n/a -
Oscilloscopes
UNI-T 2 Channel UPO2102E Ultra Phosphor Oscilloscope
- 100MHz bandwidth
- number of channels 2
- sampling 1GS / s
- max memory depth 56Mpts (per channel) (previously 28Mpts per channel)
- waveforms per second up to 80,000 wfms/s (formerly 50,000 wfms/s)
- time base range 5ns/div – 50s/div
- input coupling (1MΩ ± 2%) // (20pF ± 3pF)
- verical axis 1mV/div – 20V/div (1MΩ)
- DC gain accuracy ± 3%
- number of saved waveforms 65000
- trigger : Edge, Window, Runt, Time Out, Nth Edge, Delay, Duration, Setup / Hold, Pulse Width, Slope, Video, Pattern, RS232 / UART, I2C, SPI
- mathematical operations with waveforms : A + B, A-B, AxB, A / B, FFT, Logic operation, Editable Advanced, Filter
- automatic Measurement : Max, Min, High, Low, Middle, Pk-Pk, Ample, Mean, Cycle Mean, RMS, Cycle RMS, Cycle Area, OverShoot, PreShoot, Period, Freq, Rise, Fall, + Width, -Width, + Duty, -Duty, RiseDelay, FallDelay, Phase, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF
- number of measurements : 5 simultaneous measurements
- statistics : Mean, Max, Min, standard deviation, number of measurements
- frequency counter : 6 bits
- standard interfaces : USB-Host, USB-Device, LAN, AUX (Trig Out, Pass / Fail)