UT622A Digital Inductance LCR Meter


Specifications UT622A UT622C UT622E
Certificates CE, RoHS
Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
Output impedance 100Ω
Measurement parameters Primary: L/C/R/Z
Secondary: D/Q/θ/ESR
Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
Auto LCR
Test terminals Three-terminal test jacks, five-terminal test sockets
Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
Ranging mode Auto/hold
Tolerance range 1%~20%
Testing circuit mode Series/parallel mode
Clearing correction Open/short circuit
Fuse of test ports 0.1A/250V
Communication interface Mini-USB
LED alarm for tolerance
(pass: green; fail: red)
Display range
Maximum reading 99999
Minimum resolution 0.0001
Maximum accuracy 0.001
L 0.00μH~99.999H
C 0.00pF~99.999mF
Z/R 0.0000Ω~9.9999MΩ
ESR 0.0000Ω~999.99Ω
D 0.0000~9.9999
Q 0.0000~99999
θ -179.9°~179.9°
DCR 0.01mΩ–20.000MΩ
Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
General Characteristics
Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
Display 2.8′ TFT LCD 320X240
Product net weight 420g
Product size 93mm x 192mm x 44mm
Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual

57,410

Compare

UT622A Digital Inductance LCR Meter

Precision LCR Meter – Up to 0.1% high accuracy measurements, the unit mainly measures inductance (L), capacitance (C), resistance (R) of components, also measures impedance (Z), dissipation factor (D), quality factor (Q), angle phase (θ), and ESR.
Accurate Measurement – Selectable 4 test frequencies of 100Hz, 120Hz, 1kHz, and 10kHz. Selectable 3 test levels of 0.1V, 0.3V, and 1V. Selectable tolerance of 1%, 5%, 10%, and 20%. Able to select parallel or series increasing accuracy of in-circuit testing. Auto-off in 5min, 15min(default), 30min, or 60min are selectable.
3 Measurement Speeds – Slow(2 times per second), medium(5 times per seconds) and fast(20 times per second).
Tolerance Comparison – Equipped with audible/visual alarm, and counter features for tolerance fail/pass test.
Data Logger – The average, maximum, minimum value can be recorded via data logging mode.
Zeroing – Open/short zeroing eliminates connection errors, deliver more accurate measurement each times.
USB to PC – Transfer data to the PC/Laptop through a USB port, and exports to image file(jpg.), Excel and PDF report is available.
Portable – High resolution LCD with 5 digit display, lightweight, portable, and battery operated.
Applied in the product development, incoming inspections, or production line testing.

Category:

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT622A Digital Inductance LCR Meter”

There are no reviews yet.

  • UT715 Multifunction Loop Process Calibrator

    0 out of 5
    (0)

    Features of UT715 Multifunction Loop Process Calibrator

    Certifications: CE, UKCA

    ● Step/ramp functions

    ● Source and measure accuracy up to 0.02%
    ● Rechargeable battery
    ● Contrast adjustment
    ● Auto power off (Time adjustable)
    ● Stores and recalls setups
    ● USB communication
    ● Provides 24V loop power to transmitter while conducting mA current measurement at the same time
    SKU: n/a
  • UDP1306C Industrial Linear DC Power Supply

    0 out of 5
    (0)

    Features of UDP1306C Industrial Linear DC Power Supply:

    • 4-digit high precision display
    • OVP OCP OTP protection
    • Output setting viewable
    • Remote control (output ON/OFF)
    • Shutdown memory/keypad lock
    • Intelligent cooling fan
    • USB charging interface
    • RS232 program-controlled communication
    • USB device communication
    • 5 sets of data storage
    SKU: n/a
  • UT70B Modern Digital Multi-Purpose Meters

    0 out of 5
    (0)

    Portable digital multimeter UNIT UT70B with advanced design. Photoelectric separation guarentees absolutely secure galvanic isolation of multimeter from PC. … DC Voltage: 400mV / 4V / 40V / 400V / 1000V.

    SKU: n/a
  • CLAMP METER AC BM 2000B

    0 out of 5
    (0)

    SPECIFICATIONS:

    – Maximum display: 1999
    – Method indication: LCD
    – Maximum arm span: 60mm
    – Operating temperature range:
    work: 0C – 40C
    Storage:-10C – 60C
    – Power supply: 9V battery
    – Low battery indication: YES, graphic symbol
    – Audible indication: YES, piezoelectric transducer
    – Dimensions: 270x100x45 mm
    – Weight: about 610g (with battery)

    Features
    – Measuring voltage: 0-1000V 2 range
    – Measurement of AC voltage: 0-700V in 1 range
    – Measurement of alternating current: 200A-2000A in 2 ranges
    – Measuring current: 200A-2000A in 2 ranges
    – Measurement of resistance: 2k in 1 range
    – Measuring capacity: NO
    – Frequency: NO
    – Temperature measurement: NO
    – Testing LEDs: YES
    – Acoustic continuity tester: YES
    – Distance between arms: 6cm
    – Meter dimensions: 270x100x45 mm
    – Weight: 610g with battery
    – Basic accuracy: ± (0.5% +2 digits)

    Packages Include:

    1 × Clamp-On Meter BM-2000B

    An internal link is any link from one page on your website to another page on your website. Both your users and search engines use links to find content on your website. Your users use links to navigate through your site and to find the content they want to find. Search engines also use links to navigate your site. They won’t find a page if there are no links to it. There are several types of internal links. In addition to links on your homepage,mean post feed, etc, you can also add links within your content. We call those contextual links. Contextual links point your users to interesting and related content.
    SKU: n/a
  • YH 900M I TIP

    0 out of 5
    (0)
    SKU: n/a