- Model: YH-3010D
- Compact Design
- All Metal Construction
- Dual LED Display
- High Stabilized Output Voltage
- Short Circuit Protection
- Over Loading and Current Protection
This model has compact design with all metal construction.
1.This unit now features a Dual LED display with highly accurate LED digital readout.
2.Maximum output is 30V at 10A.
5.Over loading and current protection.
₨22,500 ₨25,008
Weight | 2.5 kg |
---|---|
Dimensions | 15 × 15 × 10 cm |
Operating Conditions:
Supply power: AC 220-240V, 50Hz/60Hz.
Working Temperature: -10°C ~ 40 °C
Relative Humidity: ‹ 90%
Storage Conditions: -10°C ~ 40 °C
Relative Humidity: ‹ 80%
Stable Voltage
The output voltage is between 0 and nominal value continuously adjustable
Voltage Stability: ≤0.01% +2mV
Load Stability: ≤ 0.01% +2mV
Recovery Time: ≤100µS
Ripple Noise: ≤1 MVRMS(RMS)
Temperature Coefficient: ≤ 200PPM/°C
Stable Current
The output current is between 0 and nominal value continuously adjustable
Power Stability: 0.1% + 3mA
Load Stability: 0.2% + 3mA
Ripple Noise : ≤2mArms(RMS)
UT220 series is a stable, safe and reliable3 1/2 AC and DC Digital Clamp Meters, full range overload protection and unique appearance design, which becomes more superior performance of electrical instruments. It is suitable for smelt, manufacturing, petroleum, electricpower, chemical industry etc. It’s an ideal tool for the maintenance and repair of the circuit, power equipment.
Features of UT533 Insulation Multimeter
Certifications: CE, RoHS
● AC/DC voltage measurement
● Frequency & Temperature test
Analog bandwidth | 150MHz | 250MHz | ||
Channels | 2+16 digital | 4+16 digital | 2+16 digital | 4+ 16digital |
Sampling rate (Analog) | 2.5GS/s (Single channel), 1.25GS/s (Dual channels) | |||
Sampling rate (Digital) | 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) | |||
Memory depth | 70Mpts | |||
Waveform capture rate | 200,000wfms/s | |||
Time base scale | 2ns/div~50s/div (Real-time sampling rate, memory depth display ) | |||
Time base scale (digital) | 2ns/div~40S/div[Step by 1-2-4 stall] | |||
Input impedance | (1MΩ±1%) II (20pF±3pF) | |||
Input impedance digital | (101kΩ±1%) II (9pF±1pF) | |||
Vertical scale | 1mV/div~20 V/div (1 MΩ) | |||
DC gain accuracy | <5mV: ±3%, ≥5mV: ±2% | |||
Waveform record | 100,000 frames | |||
Trigger types | Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay |
|||
Bus decode | RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay | |||
Waveform operations | A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations | |||
Auto measurements |
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width, -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A |
|||
Measurement display | 5 types | |||
Measurement statistics | Average, Max, Min, standard deviation and number of measurements | |||
Frequency counter | 6 bits | |||
Standard interfaces | USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA | |||
Standard Accessories |
USB interface cable | UT-D14 | ||
Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) | UT-P06 | |||
Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) | UT-P05 | |||
16CH Logic analyzer probe | UT-15M |
There are no reviews yet.