The BT-100D 100+ Amp Digital Battery Load Tester is microprocessor controlled. It makes for an easy and accurate load test with no need to time yourself to get accurate results. Bright, LED Digital Display indicates both voltage and test results. A unique 3-Step Design provides LED polarity check function, battery load test and charging system test readout. Automatically Turns Off the Load after 10 seconds and locks the voltage. Super-Grip Battery Clamps are heavy-duty and color-coded. Baked Enamel, Steel Case to keep cool. Rubber Insulated Carrying Handle–for comfort and safety. Checks both Battery and Charging System.
Battery Load Tester – BT 100D
7 in stock
- 100 Amp Digital Battery Load Tester
- Microprocessor Control–makes for an easy and accurate load test with no need to time yourself
- Bright, LED Digital Display–indicates both voltage and test results
- Unique 3-Step Design–LED polarity check function, battery load test and charging system test readout
- Super-Grip Battery Clamps–heavy-duty and color-coded
- Baked Enamel, Steel Case–ventilated to keep cool
- Rubber Insulated Carrying Handle–for comfort and safety
- Checks both Battery and Charging System
₨5,000 ₨7,000
7 in stock
CompareWeight | 0.7 kg |
---|---|
Dimensions | 15 × 8 × 6 cm |
12 Volt Battery Analysis
Press “START TEST” & wait for 10 seconds.
Once automatic test cycle is completed, your test results will be:
1. GREEN LIGHT = OK):
Battery capacity is good. May or may not be fully charged.
Determine state of charge by checking specific gravity (use hydrometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to fully charged level.
2. GREEN + YELLOW LIGHT = OK BUT WEAK):
Review the load test result with the comparison chart on the tester cover to see if this battery is “OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.
3. YELLOW LIGHT = WEAK):
Battery capacity is unsatisfactory. Battery may be either: (1) defective or (2) partially discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered defective. If gravity is under 1.225, recharge battery and re-test. If cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to fully charged level, the battery is either sulfated or has lost active material.
4. RED LIGHT = BAD):
Battery may be defective (e.g. a bad cell).
NOTE: If pre-test battery voltage is below 12.3V, tester will not allow and should not perform the load test. Please fully charge battery and retest.
Based on 0 reviews
Be the first to review “Battery Load Tester – BT 100D”
-
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
LCR Meter
UT620 Series Digital Micro Ohm Meters
UT620 series are used to measure DC low resistance through 4-wire method. Some of its features are: Comparison function to determine if the device is in good condition, unknown wire length calculation (FT/M); two-way data transmission by USB interface; built-in rechargeable lithium battery. UT620 can be used in narrow space for on-site troubleshooting, such as metal coating resistance/motor and small transformer winding resistance measurement, earth system joints/welding points/power distribution cabinet bus and lead connection inspection and more.
SKU: UN62B0TUOM -
Multimeters
UT58B General Digital Multimeter
1. 2000 display count, refresh rate 2~3 times/s
2. Function symbols and test lead connection indication3. Transistor measurement4. Temperature measurement mode, with K-type temperature probe5. Diode and continuity buzzer; auto power off; overload protection6. Data hold; 20A AC/DC current measurementSKU: n/a
There are no reviews yet.