-18%

Clamp Meter BM 528A


  • Digital Clamp Meter
  • 31/2LocationDigit,Maximum displayMAXDisplay:1999,Data HoldDH
  • OverloadOverLoadProtection
  • Maximum jaw openingMAXexpand of the pincers:30mm
  • Off testCONTINUITY
  • BUZZER
  • diodeDIODE

2,500 3,052

Compare
  • Digital Clamp Meter
  • 31/2LocationDigit,Maximum displayMAXDisplay:1999,Data HoldDH
  • OverloadOverLoadProtection
  • Maximum jaw openingMAXexpand of the pincers:30mm
Category:
Weight 0.3 kg
Dimensions 22 × 7 × 3 cm
DIGITAL  CLAMP  MULTIMETER
31/2 Digit,  MAX  Display:1999,
Auto power off
DH
Over  Load  Protection
Battery power is insufficient
MAX  expand of the pincers:30mm
DCV:20V±0.8%±2, 600V±1%±3
ACV:600V±1.5%±5
ACA:20/200/600A±1.9%±5
RESISTANCE:2KΩ±1.0%±3,2MΩ±1.0%±5
CONTINUITY  BUZZER
DIODE
POWER SUPPLY:6F22 or NEDA  9V×1
SIZE:221×75×31mm
WEIGHT: about 240g(Include battery)

Brand

SZBJ

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Clamp Meter BM 528A”

There are no reviews yet.

  • UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • TDR-420 Time Domain Reflectometer/ Cable Fault Locator

    0 out of 5
    (0)

    Product features

    • Possibility damage-free location of impedance changes of tested cables and wires such as:
      • shorted conductor,
      • open conductor / end of cable – useful during the inventory of warehouses and stores,
      • splice,
      • splitter,
      • water ingress,
      • wet splice,
      • bridge tap
      • or other changes.
    • Single measurement mode ONCE,
    • Continuously measurement mode CONT,
    • Tone signal generator TONE,
    • Two cursors to mark two places of damage along with an indication of the distance between them,
    • Built-in HELP function for easier interpretation of the reflectogram,
    • 11 available measuring ranges from 7 m to 6000 m,
    • „dead zone” limited to 0.6 m,
    • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
    • manually set of sensitivity in 8 steps GAIN,
    • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
    • Velocity of Propagation set in range from 10% to 99%,
    • tight and durable housing with IP67 ingress protection degree.
    • Small size and weight.
    SKU: n/a
  • UT206A+

    0 out of 5
    (0)

    1. 1000A AC current measurement
    2. 1000V AC/DC voltage measurement
    3. 600A inrush current measurement (UT206A+)
    4. Temperature (UT206A+)
    5. NCV (UT206A+)
    6. ACV frequency 10Hz~10kHz
    7. Jaw opening: 45mm
    8. Resistance / capacitance / frequency measurement
    9. Auto range / backlight / low battery indication
    10. Continuity / diode / duty cycle
    11. MAX/MIN
    12. Data hold / flashlight / relative mode
    13. Auto power off
    14. CAT II 1000V/CAT III 600V

    SKU: n/a
  • LM585LD Laser Levelers

    0 out of 5
    (0)

    Features of LM570/585 Series Laser Levelers

    Certificates (LM570LD-II/575LD only): CE, UKCA

    ● Osram LD green laser
    ● Self-leveling mode & manual mode
    ● Outdoor pulse mode

    ● 5200mAh Li-ion battery
    ● Type-C DC-in port
    ● Complimentary bracket

    SKU: n/a
  • UT61E Modern Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. 22,000 display count, can measure weak signals

    2. Analogue bar graph

    3. True RMS measurement

    4. 220mF capacitance measurement

    5. Peak hold: auto hold the max/min value of pulse signals

    6. Diode test and buzzer continuity

    7. Auto range

    8. MAX/MIN/REL measurement mode

    9. Overload protection for all ranges

    10. Data hold

    11. Complies with CE (European Union) directives

    SKU: n/a