- clamp multimeter
- Performs AC/DC Voltage, AC current, Resistance, Audible Continuity, Diode
- Temperature Measurements, and non-contact ACV Detect (NCV) as well as Capacitance, Hz, etc.
- Auto Ranging DMM with AC current clamp meter function
Clamp Meters
Clamp Meter DT 3266
Availability:
Out of stock
- clamp multimeter
- Performs AC/DC Voltage, AC current, Resistance, Audible Continuity, Diode
- Temperature Measurements, and non-contact ACV Detect (NCV) as well as Capacitance, Hz, etc.
- Auto Ranging DMM with AC current clamp meter function
₨811 ₨1,308
Out of stock
CompareWeight | 0.3 kg |
---|---|
Dimensions | 15 × 7 × 4 cm |
FUNCTION | MEASURING RANGE | ACCURACY | ||
DCV | 200mv/2v/20v/200v | ±(0.8%+2) | ||
600v | ±(1.0%+2) | |||
400mv/4v/40v/400v | ±(0.8%+2) | |||
600v | ±(1.0%+2) | |||
ACV | 2V/20V/200V | ±(1.0%+5) | ||
600V | ±(1.2%+5) | |||
400mv/4v/40v/400v | ±(1.0%+10) | |||
600V | ±(1.2%+10) | |||
ACA | 2A/20A | ±(3.0%+10) | ||
200A | ±(2.5%+10) | |||
4A/40A/400A | ±(2.5%+10) | |||
600A | ±(1.5%+5) | |||
Ω | 200Ω/2KΩ/20KΩ/200KΩ/2MΩ | ±(1.2%+2) | ||
20MΩ | ±(2.0%+5) | |||
400Ω/4KΩ/40KΩ/400KΩ/4MΩ | ±(1.2%+2) | |||
40MΩ | ±(2.0%+5) | |||
CX | 200uf | ±(4.0%+10) | ||
HZ | 0∞10MHZ | ±(2.0%+5) | ±(1.5%+15) | |
°C | – 20°C ≤ 750°C | ±(2%+2) | ||
FEATURE | ||||
LCD | DIGITS | 1999 | 3999 | |
Clamp Size | Opening | 30mm | 30mm | |
Test Range | Ac voltage/dc voltage/AC-DC current,resistance | • | • | |
Capacitance/frequency/duty cycle/temperature | • | |||
Power | 3X1.5v AAA | |||
Weight | 133.5g | |||
Security | CE,ETL,CATIII 600V ROHS |
Based on 1 review
Add a review
-
Insulation Tester
MIC-15k1 ,15kV Insulation Quality Analyzer
Features:
- Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
- It allows testing the electrical durability of the tested object – breakdown voltage indication.
- High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
- The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
- Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
- visual method (if power cables are visible along the entire length),
- reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
- Compatible with external software.