-38%

Clamp Meter DT 3266

(1 customer review)
Availability:

Out of stock


  • clamp multimeter
  • Performs AC/DC Voltage, AC current, Resistance, Audible Continuity, Diode
  • Temperature Measurements, and non-contact ACV Detect (NCV) as well as Capacitance, Hz, etc.
  • Auto Ranging DMM with AC current clamp meter function

811 1,308

Out of stock

Compare
  • clamp multimeter
  • Performs AC/DC Voltage, AC current, Resistance, Audible Continuity, Diode
  • Temperature Measurements, and non-contact ACV Detect (NCV) as well as Capacitance, Hz, etc.
  • Auto Ranging DMM with AC current clamp meter function
Category:
Weight 0.3 kg
Dimensions 15 × 7 × 4 cm
FUNCTION MEASURING RANGE ACCURACY
DCV 200mv/2v/20v/200v ±(0.8%+2)
600v ±(1.0%+2)
400mv/4v/40v/400v ±(0.8%+2)
600v ±(1.0%+2)
ACV 2V/20V/200V ±(1.0%+5)
600V ±(1.2%+5)
400mv/4v/40v/400v ±(1.0%+10)
600V ±(1.2%+10)
ACA 2A/20A ±(3.0%+10)
200A ±(2.5%+10)
4A/40A/400A ±(2.5%+10)
600A ±(1.5%+5)
200Ω/2KΩ/20KΩ/200KΩ/2MΩ ±(1.2%+2)
20MΩ ±(2.0%+5)
400Ω/4KΩ/40KΩ/400KΩ/4MΩ ±(1.2%+2)
40MΩ ±(2.0%+5)
CX 200uf ±(4.0%+10)
HZ 0∞10MHZ ±(2.0%+5) ±(1.5%+15)
°C  – 20°C ≤ 750°C ±(2%+2)
FEATURE
LCD DIGITS 1999 3999
Clamp Size Opening 30mm 30mm
Test Range Ac voltage/dc voltage/AC-DC current,resistance           •          •
Capacitance/frequency/duty cycle/temperature          •
Power 3X1.5v AAA
Weight 133.5g
Security CE,ETL,CATIII 600V ROHS

Brand

SZBJ

Based on 1 review

5.0 overall
1
0
0
0
0

Add a review

  1. Zafar Ayyub

    Dt3266 clampmeter

    Zafar Ayyub

  • UT683KIT Wire Tracker

    0 out of 5
    (0)

    Features of UT683KIT Wire Tracker

    Certifications: CE, UKCA

    ● Line function

    ● NCV function

    ● Withstand voltage DC 60V

    ● Port flashes

    SKU: n/a
  • PQM-707 Power Quality Analyzer

    0 out of 5
    (0)
    • Features:

      • 7″ touch screen – intuitive operating
      • CAT IV 600V – high safety
      • all parameters acc. to class S – high accuracy of measurements
      • Li-Ion rechargeable battery – higher mobility
      • removable memory card – recording data with no restrictions

      Possible measurements:

      • Measurements according to EN 50160,
      • Voltage L1, L2, L3, N-PE (five inputs),
        – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
      • Current L1, L2, L3, N (four inputs),
        – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
      • Crest factor for voltage and current,
      • Frequency from 40 Hz to 70 Hz ,
      • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
      • Power recording:
        • Budeanu method,
        • IEEE 1459,
      • Active, reactive, apparent energy,
      • Power factor, cosφ, tgφ,
      • Up to 50th harmonics for voltage and current,
      • Total Harmonic Distortion (THD) for voltage and current,
      • Short-term (PST) and long-term (PLT) flicker,
      • Unbalance of voltage and current,
      • Current and voltage events registration including waveforms and RMS graphs half period,
      • Inrush current
      • Calculator of energy tariffs
      • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
    SKU: n/a
  • UT18B Voltage And Continuity Testers

    0 out of 5
    (0)

    UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
    Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.

    SKU: n/a
  • UT52 Standard Digital Multimeters

    0 out of 5
    (0)

    UT50 series is a manual range digital multimeter. Lrage display,multi purpose use.Ac dc volts,ac dc amperes resistance and buzzer functions.

    SKU: n/a
  • UT622A Digital Inductance LCR Meter

    0 out of 5
    (0)
    Specifications UT622A UT622C UT622E
    Certificates CE, RoHS
    Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
    Output impedance 100Ω
    Measurement parameters Primary: L/C/R/Z
    Secondary: D/Q/θ/ESR
    Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
    Auto LCR
    Test terminals Three-terminal test jacks, five-terminal test sockets
    Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    Ranging mode Auto/hold
    Tolerance range 1%~20%
    Testing circuit mode Series/parallel mode
    Clearing correction Open/short circuit
    Fuse of test ports 0.1A/250V
    Communication interface Mini-USB
    LED alarm for tolerance
    (pass: green; fail: red)
    Display range
    Maximum reading 99999
    Minimum resolution 0.0001
    Maximum accuracy 0.001
    L 0.00μH~99.999H
    C 0.00pF~99.999mF
    Z/R 0.0000Ω~9.9999MΩ
    ESR 0.0000Ω~999.99Ω
    D 0.0000~9.9999
    Q 0.0000~99999
    θ -179.9°~179.9°
    DCR 0.01mΩ–20.000MΩ
    Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
    General Characteristics
    Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
    Display 2.8′ TFT LCD 320X240
    Product net weight 420g
    Product size 93mm x 192mm x 44mm
    Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual
    SKU: n/a