-11%

UT213C ACA DCA Digital Clamp Meters

Availability:

20 in stock


Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

15,600 17,440

20 in stock

Compare

Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

Category:
Weight 0.23 kg
Dimensions 22 × 7 × 4 cm
Specifications Range Best Accuracy
Model UT213C
AC Current (A) 40A/400A ±(2.5%+5)
DC Current (A) 40A/400A ±(2.0%+3)
AC Voltage (V) 4V/40V/400V/600V ±(1.2%+5)
DC Voltage (V) 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance (Ω) 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1.0%+2)
Capacitance (F) 40nF400nF/4μF/40μF/400μF/4mF/40mF ±(4.0%+5)
Frequency (Hz) 10Hz-1MHz ±(0.1%+4)
Temperature (°C) -40 °C ~ 1000°C ±(1.0%+3)
Temperature (°F) -40℉ ~  1832℉ ±(1.0%+6)
Features
Display Count 4000
Auto Range
Jaw Capacity 30mm
True RMS
Diode √(Around 3.0V)
NCV
Data Hold
Relative Mode
MAX/MIN
LCD Backlight
Flashlight
Auto Power Off
Continuity Buzzer
Low Battery Indication ≤3.6V
Input Protection
Input Impedance for DCV ≥10MΩ
General Characteristic 
Power AAA 1.5V × 3
LCD Size 38mm × 24 mm
Product Color Red and Grey
Product Net Weight 231.7g
Product Size 220mm ×  75mm ×  40mm
Standard Accessories Batteries, Test Lead,Point Contact Temperature Probe
Standard Individual Packing Gift Box, Carrying Bag, English Manual
Standard Quantity Per Carton 40 PCs
Standard Carton Measurement 485mm × 320mm × 385mm (0.060 CBM Per Standard Carton)
Standard Carton Gross Weight 20Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT213C ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • UT725 Multifunction Process Calibrator

    0 out of 5
    (0)

    Features of UT725 Multifunction Process Calibrator

    Certifications: CE, UKCA

    ● Step/ramp functions

    ● Source and measure accuracy up to 0.02%
    ● Rechargeable battery
    ● Contrast adjustment
    ● Auto power off (Time adjustable)
    ● Stores and recalls setups
    ● USB communication
    ● Simultaneously measure and output different process signal in real time
    ● Pressure measure with specified pressure modules, and sourcing pressure
    ● Provides 24V loop power to transmitter while conducting mA current measurement at the same time
    SKU: n/a
  • JM 8147

    0 out of 5
    (0)
    SKU: n/a
  • UT622A Digital Inductance LCR Meter

    0 out of 5
    (0)
    Specifications UT622A UT622C UT622E
    Certificates CE, RoHS
    Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
    Output impedance 100Ω
    Measurement parameters Primary: L/C/R/Z
    Secondary: D/Q/θ/ESR
    Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
    Auto LCR
    Test terminals Three-terminal test jacks, five-terminal test sockets
    Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    Ranging mode Auto/hold
    Tolerance range 1%~20%
    Testing circuit mode Series/parallel mode
    Clearing correction Open/short circuit
    Fuse of test ports 0.1A/250V
    Communication interface Mini-USB
    LED alarm for tolerance
    (pass: green; fail: red)
    Display range
    Maximum reading 99999
    Minimum resolution 0.0001
    Maximum accuracy 0.001
    L 0.00μH~99.999H
    C 0.00pF~99.999mF
    Z/R 0.0000Ω~9.9999MΩ
    ESR 0.0000Ω~999.99Ω
    D 0.0000~9.9999
    Q 0.0000~99999
    θ -179.9°~179.9°
    DCR 0.01mΩ–20.000MΩ
    Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
    General Characteristics
    Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
    Display 2.8′ TFT LCD 320X240
    Product net weight 420g
    Product size 93mm x 192mm x 44mm
    Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual
    SKU: n/a
  • UT533 Insulation Multimeter

    0 out of 5
    (0)

    Features of UT533 Insulation Multimeter

    Certifications: CE, RoHS

    ● AC/DC voltage measurement

    ● AC/DC current measurement
    ● Insulation resistance measurement
    ● Resistance & Capacity test

    ● Frequency & Temperature test

    ● 1000V output voltage
    ● Double insulation design
    SKU: n/a