-18%

CMM-10 Multimeter

Availability:

5 in stock


  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).

11,844 14,478

5 in stock

Compare

The most important features of CMM-10 are:

  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).
Category:
Weight 0.2 kg
Dimensions 14 × 7 × 4 cm

Frequency measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
50,00 Hz 0,01 Hz
500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
5,000 kHz 0,001 kHz
50,00 kHz 0,01 kHz
500,0 kHz 0,1 kHz
5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
10,00 MHz 0,01 MHz
  • sensitivity: ≥8 V RMS

Duty cycle measurement

Range Resolution Accuracy
0,1…99,9% 0,1% ±(1,2% m.v. + 2 digits)
  • sensitivity: ≥8 V RMS,
  • pulse width: 100µs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy*
-20°C…+760°C 1°C ±(3% m.v. + 5°C, 9°F)
-4°F…+1400°F 1°F

*) probe (K type) accuracy not included

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
400,0 V 0,1 V
600 V 1 V ±(1,5% m.v. + 2 digits)
  • input impedance: 7,8 MΩ

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
400,0 V 0,1 V
600 V 1 V ±(2,0% m.v. + 4 digits)
  • input impedance: 7,8 MΩ,
  • frequency range: 50…400 Hz.

DC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
4 000 μA 1 μA ±(1,5% m.v. + 3 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
10,00 A 0,01 A

AC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,5% m.v. + 5 digits)
4 000 μA 1 μA ±(1,8% m.v. + 5 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(3,0% m.v. + 7 digitgs)
10,00 A 0,01 A
  • frequency range: 50…400 Hz.

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ
4,000 MΩ 0,001 MΩ
40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
4,000 μF 0,001 μF
40,00 μF 0,01 μF
100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

“m.v” = measured value

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT II 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,3 mA, U0 = 1,5 V DC
  • continuity test: I<0,3 mA, sound signal for R<50 Ω
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 7,8 MΩ (V AC/DC)
  • display: 5000 counts LCD display with function indication
  • dimensions: 138 x 68 x 37 mm
  • weight: approx. 210 g
  • fuses: mA, µA range: 0,5 A/250 V fast; A range: 10 A/250 V fast
  • auto power OFF: 30 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • operating temperature: 0…+50°C at <70% rel. humidity
  • storage temperature: -20…+60°C at <80% rel. humidity

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-10 Multimeter”

There are no reviews yet.

  • UT353-BT Mini Sound Level Meter

    0 out of 5
    (0)

    1. White backlight, clear LCD screen

    2. Adjustable sampling rate, fast/slow
    3. 1/2 inch condenser microphone
    4. Light weight, ergonomic design, user-friendly interface
    SKU: n/a
  • JM-6099 31 in 1 Multifunctional Screwdriver Set Kit Tools

    0 out of 5
    (0)
    Features:
    31-in-1 interchangeable precise manual tool set.
    Professional portable hardware tools.
    Light weight, compact design.
    High hardness and good toughness.

    PP&TPR material, non-slip handle.

    SKU: n/a
  • UT258A AC/DC Leakage Clamp Meter

    0 out of 5
    (0)

    UT258A is well designed for on-line measurement of DC/AC leakage current and current below 600V, which adopts latest CT and digital integration technology. Slender clamp is very suitable for places full of concentrated cables (such as, electric power metering system, high-speed rail system, automobile circuit maintenance and so on). Non-contact measurement ensures operation safety. The meter has mini shape with high accuracy, stable performance and perfect functions.

    SKU: n/a
  • UT501A Insulation Resistance Tester

    0 out of 5
    (0)

    1. 2000 count LCD display, overload indication, backlight

    2. AC voltage measurement, auto power off
    3. Auto discharge
    4. Continuous measurements mode, red warning light and buzzer function
    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a