Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.
CMM-40 Industrial Multimeter
5 in stock
The most important features of CMM-40 are:
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- „REL” function, which allows you to make measurements relative to a stored reference value,
- „MAX/MIN” function,
- „PEAK HOLD” function,
- memory for 2000 measurement resultS,
- continuity test with acoustic signalling (beeper),
- „AUTO-OFF” function,
- display 4¾ digits (40000 max),
- double molded, waterproof casing.
₨30,270 ₨34,221
5 in stock
CompareWeight | 0.4 kg |
---|---|
Dimensions | 19 × 8 × 5 cm |
Frequency measurement (electronic)
Range | Resolution | Accuracy |
40,000 Hz | 0,001 Hz | ±(0,1% m.v. + 1 digit) |
400,00 Hz | 0,01 Hz | |
4,0000 kHz | 0,0001 kHz | |
40,000 kHz | 0,001 kHz | |
400,00 kHz | 0,01 kHz | |
4,0000 MHz | 0,0001 MHz | |
40,000 MHz | 0,001 MHz | |
100,00 MHz | 0,01 MHz | not speccified |
- Sensitivity: 0.8 V rms min. @ 20% to 80% duty cycle and <100 kHz; 5 V rms min @ 20% to 80% duty cycle and > 100 kHz
Frequency measurement (electrical)
Range | Resolution | Accuracy |
40,00 Hz…10,000 kHz | 0,01 Hz…0,001 kHz | ± 0,5% m.v. |
- sensitivity: 1 V rms
Duty cycle measurement
Range | Resolution | Accuracy |
0,10…99,00% | 0,01% | ±(1,2% m.v. + 2 digits) |
- pulse width: 100μs – 100 ms,
- frequency width: 5 Hz…150 kHz.
Temperature measurement
Range | Resolution | Accuracy |
-50,0°C…+1200,0°C | 0,1°C | ±(1% m.v. + 2,5°C) |
-58,0°F…+2192,0°F | 0,1°F | ±(1% m.v. + 4,5°F) |
DC voltage measurement
Range | Resolution | Accuracy |
400,0 mV | 0,01 mV | ±(0,06% m.v. + 4 digits) |
4,0000 V | 0,0001 V | |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V | ±(0,1% w.m. + 5 cyfr) |
AC voltage measurement (True RMS)
Range | Resolution | Accuracy |
400,00 mV | 0,01 mV | ±(1% m.v. + 40 digits) |
4,0000 V | 0,0001 V | ±(1% m.v. + 30 digits) |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V |
- frequency range: 50…1000 Hz.
AC/DC current measurement (True RMS)
Range | Resolution | Accuracy |
400,00 μA | 0,01 μA | dla DC ±(1,0% m.v. + 3 digits)
dla AC ±(1,5% m.v. + 30 digits) |
4 000,0 μA | 0,1 μA | |
40,000 mA | 0,001 mA | |
400,00 mA | 0,01 mA | |
10,000 A | 0,001 A |
- 20 A: 30 sec max with reduced accuracy.
Resistance measurement
Range | Resolution | Accuracy |
400,00 Ω | 0,01 Ω | ±(0,3% m.v. + 9 digits) |
4,0000 kΩ | 0,0001 kΩ | ±(0,3% m.v. + 4 digits) |
40,000 kΩ | 0,001 kΩ | |
400,00 kΩ | 0,01 kΩ | |
4,0000 MΩ | 0,0001 MΩ | |
40,000 MΩ | 0,001 MΩ | ±(2,0% m.v. + 10 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
40,000 nF | 0,001 nF | ±(3,5% m.v. + 40 digits) |
400,00 nF | 0,01 nF | |
4,0000 μF | 0,0001 μF | ±(3,5% m.v. + 10 digits) |
40,000 μF | 0,001 μF | |
400,00 μF | 0,01 μF | |
4000,0 μF | 0,1 μF | ±(5% m.v. + 10 digits) |
40,000 mF | 0,001 mF |
Other technical data:
- power supply: 9 V battery type 6LR61
- diode test: I=0,9 mA, U0 = 2,8 V DC
- continuity test: I<0,35 mA, sound signal for R<35 Ω
- over range indication: 0L displayed
- crest factor: ≤ 3 at full scale up to 500 V; decreasing linearly to ≤ 1,5 at 1000 V
- PEAK: captures peaks >1 ms
- sampling rate: 2 times per second
- input impedance: 10 MΩ (V DC), 9 MΩ (V AC)
- display: 40000 counts backlit LCD with bargraph, 4¾ digits
- store capacitance: 2000
- dimensions: 187 x 81 x 55 mm
- weight: 342 g
- fuses: mA, µA range: 0,5 A/1000 V ceramic fast blow; A range: 10 A/1000 V ceramic fast blow
- auto power OFF: 15 min.
- accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
Electric security:
- type of insulation: double, according to EN 61010 – 1 and IEC 61557
- measurement category: CAT III 1000 V acc. to EN 61010 – 1:2004
- protection class acc. to EN 60529: IP67
Rated operational conditions:
- operating temperature: 0…+40°C
- storage temperature: -20…+60°C
- operating humidity: max 80% up to 87°F (31°C); decreasing linearly to 50% at 104°F (40°C)
- operating altitude: max 2000 m
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMM-40 Industrial Multimeter”
-
Wire & Cable Testers
TDR-410 Cable Fault Locator
-
Features:
- automatic or manual mode:
- the automatic fault location (AFL),
- mode with manual range selection and sensitivity,
- single measurement triggered manually or scanning continuous,
- 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
- maximum length of cable up to 4000 m one end of the cable,
- “Dead zone” measure limited to 0.5 m,
- 2.5 “LCD screen with backlight,
- scan automatically or manually trigger,
- sensitivity set manually or automatically adjusted,
- adjustable impedance matching,
- propagation coefficient adjustment 1% to 99%,
- waterproof and resistant to mechanical housing.
- small size and weight.
- economical power system – 30 hours of continuously scan on one battery set..
Accessories:
- 0,6 m double-wire lead: WAPRZ0X6DZBB
- red crocodile clip: WAKRORE20K02
- Krokodylek czarny: WAKROBL20K01
- cover M-2: WAFUTM2
- automatic or manual mode:
SKU: n/a -
-
Wall Scanner
UT387S Wall Scanners
UT387S wall scanners are used to detect a variety of objects behind the wall, designed with multiple measurement modes and additional function to conveniently measure the laser distance and wood moisture detection. They are widely used in home renovation, home improvement and DIY projects.
SKU: n/a -
Multimeters
DM 6013 LC METER
Features Of Handheld Mini Capacitor Meter Capacimeter DM6013L:
- Automatic in zeroing and polar selection
- Wide measuring range, covering 9 measuring sections from 0.1pF to 20,000uF
- Max. display: 1999 counts(3 1/2digits)
- Data Hold
- LCD backlight
- Two ways to test capacitance,input jack and meter pen,convenient to operate.
SKU: 4000