-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • TITAN Clamp Multimeter TN88A in Pakistan

    0 out of 5
    (0)

    Specifications:

    • TITAN TN88A Digital Clamp Meter 500V Insulation Tester
    • DC voltage: 1000V ± (0.8% + 2)
    • AC voltage: 750V ± (1.2% + 4)
    • Alternating current: 200A / 1000A ± (2.5% + 5)
    • Resistance: 200Ω / 20kΩ ± (1.0% + 2)
    • Insulation test 100kΩ to 2000MΩ (with option 500V insulation tester unit)
    • High Resistance: 20MΩ / 2000MΩ ± (5.0% + 2)
    • The continuity of the alarm
    • Low screen voltage
    • Data retention
    • Input impedance: 10MΩ
    • Sampling rate: 3 times / s
    • Maximum display: 1999
    • Jaw opening: 50mm
    SKU: n/a
  • Digital Radiation Tester ET825 Handheld Electric and Magnetic Field Radiation Detector with Sound and Light Alarm

    0 out of 5
    (0)

    Model: ET825
    Material: ABS
    Power Supply: 3xAAA 1.5V Battery (Battery Not Included)
    Application: It is suitable for electromagnetic radiation testing.
    Monitoring Places: It can detect radiation in homes, offices, outdoors, and industrial places.
    Testing Items: It can perform radiation testing on mobile phones, computers, TVs, refrigerators, and high-voltage lines.
    Radiation Protection Products Inspection: it can test the effects of radiation protection clothing, radiation protection films and other protective equipment.

    SKU: n/a
  • ,

    JM-6118 33 in 1 Screwdriver Tool Set

    0 out of 5
    (0)

    Main Features:
    • Shank: 130mm, tweezers: 118mm, extension soft bar: 120mm.
    • Dismantling and precision screwdriver bit.
    • Convenient for storaging and carrying.

    SKU: n/a
  • ,

    LCD Screen opening plier JM-OP10

    0 out of 5
    (0)

    Feature:
    Ergonomically designed handle with slip-resistant grip for comfortable bold.
    Multi-angle adjustable, removable, powerful suction cup.
    It can effectively adsorb LCD screen.
    It is very good to improve work efficiency.

    SKU: n/a
  • UTG9002C-II Function/Arbitrary Waveform Generator

    0 out of 5
    (0)

    1. Output waveforms: Sine, square, ramp, pulse, noise, DC, arbitrary

    2. Output frequency range: Sine/square, 2MHz
    3. High-accuracy, broad-band 6 bit frequency counter, range: 100mHz~100MHz
    4. EBTN LCD screen
    SKU: n/a