-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • RF-0.5x

    0 out of 5
    (0)
    SKU: n/a
  • JM-6108 Ratchet Screwdriver Bits Set

    0 out of 5
    (0)

     

    Features:

    • Ratchet screwdrivers with twist reverse and ratchet lock mechanism.
    • Contoured comfort grip handle. Supplied in storage case.
    • 180 degrees angle ratchet screwdriver.
    • Forward & Reverse with locking action.
    • Adjustable screwdriver bits for different screws.
    • Common used in automotive parts and home appliances.
    SKU: n/a
  • LM40 Laser Distance Meter

    0 out of 5
    (0)

    1. Ergonomic exterior, comfortable handling

    2. Millimeter accuracy
    3. Large, multiple angle HD display
    5. Physical and electronics leveler
    6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more
    7. Auto power off after 3 minutes without operation
    SKU: n/a
  • UT658B USB Tester

    0 out of 5
    (0)

    UT658 series USB testers are used to inspect USB chargers and portable power source of electronics products. UT658 series can output voltage, current, and power. Users can use these devices to monitor charging status of  any USB powered device.

    SKU: n/a
  • UT52 Standard Digital Multimeters

    0 out of 5
    (0)

    UT50 series is a manual range digital multimeter. Lrage display,multi purpose use.Ac dc volts,ac dc amperes resistance and buzzer functions.

    SKU: n/a