  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • UT216A 600A Digital Clamp Meters

    0 out of 5
    (0)

    UT216 series true RMS digital clamp meter is a new-generation practical electrotechnical measurement meter which has the features of high reliability, high safety, automatic range and handheld type, has full-range overload protection and unique appearance design, is more excellent in performance, and is an ideal tool for detection, maintenance and repair of various universities and colleges, smelting, communication, manufacturing, petroleum, national defense, electrical, power and circuit equipment.
    UTD216A (main features)

    • 1、600A AC current measurement
    • 2、True RMS response for ACV and ACA
    • 3、99.99mF capacitance measurement
    • 4、Non-contact voltage detection with LED indication
    • 5、Flashlight for working at dark environment
    SKU: n/a
  • JAKEMY JM-6032 Interchangeable Precise Manual Tool Set

    0 out of 5
    (0)

    JAKEMY JM-6032 Interchangeable Precise Manual Tool Set

    SKU: n/a
  • JM T2-12 TEWZER

    0 out of 5
    (0)
    SKU: n/a
  • UNI-T UT3513 DC Resistance Tester Microohmmeter 4.3 Inch LCD Screen Cable/Coil/Motor Resistance Test

    0 out of 5
    (0)
    Model UT3513
    Resistance range 20m Q/200m Q/2Q/20Q /200 Q/2kQ/20kQ
    Resolution 1 u Q/10 u Q/100 u Q/lmO/lOmQ/lOOmQ/1 Q/10Q/100Q
    Test current 1A/1A/100mA/10mA/1mA/1mA/100 uA/10 u A/l uA
    Testing terminal opencircuit voltage <1V/<1V/<1V/<1V/<5V/<5V/<5V/<5V/<3V/
    Measured parameter DC resistance
    Basic accuracy Slow: 0. 1%; Medium: 0. 2%
    Maximum reading 22000
    Range mode Auto/Manual/nominal
    Calibration Short-circuit full range zeroing
    Sorting function 3types of resistance and voltage input: exceeds upper limit/exceeds lower limit/within the range,2 types of sorting result output: PASS/FAIL
    Comparing method Absolute tolerance, percentage tolerance, direct-reading comparison
    Trigger mode Internal, external
    Test terminal Four-terminal measurement
    Button functions Lock 一一 keyboard lock, OK 一一 screenshot
    System setup Language: Chinese/English, key tone setting
    Interfaces & protocols Handler interface, RS232, USB DEVICE and USB HOST communication interface,SCPI and Modbus protocol
    Upper computer software V
    Power AC 100~240V 50/60Hz
    Display 4.3-inches LCD
    SKU: n/a
  • UT-L 33Test Leads

    0 out of 5
    (0)
    SKU: n/a
  • JM T10-12 TEWZER

    0 out of 5
    (0)
    SKU: n/a