-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • UT347A Leeb Hardness Tester

    0 out of 5
    (0)

    Features of UT347A Leeb Hardness Tester

    Certificates: CE (In processing), UKCA

    ● 6 kinds of hardness values (HL, HB, HRC, HRB, HV, HS) is a real-time measurement
    ● One hardness tester can be equipped with 7 different impact devices
    ● Automatic identification without calibration when replacing impact device
    ● Statistical, multi-unit, line chart, histogram 4 measurement modes
    ● Camera: 640×480 pixels (900 BMP format pictures could be stored)
    ● Automatic alarm when the upper and lower limits are exceeded
    ● Adjustable backlight brightness
    ● Mobile phone Bluetooth APP and PC software analysis data
    ● Support thermal printing
    ● Tri-color LED indication and LED flashlight
    SKU: n/a
  • UT 196

    0 out of 5
    (0)

    1. True RMS
    2. Measure up to 1700V DC and 1500V AC for high voltage applications such as solar array, wind and other power utility maintenance
    3. Analog bar
    4. Frequency response:45Hz~1kHz
    5. IP65 protection
    6. CAT III 1000V, CAT IV 600V

    SKU: n/a
  • Fluke 18B+ Digital Multimeter

    0 out of 5
    (0)

    Feature:

    -New Function:Frequency Test

    -New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light

    -Two Mode LED Test :

    -DMM LED Socket Test Mode .

    -UUT(PCBA) LED Test Mode(using test lead).

    -Light up LED without considering the polarity.

    -Voltage,Resistance,Continuity Testing,Capacitance Test.

    -Data Hold,Diode Test.

    -Frequency and Duty Cycle.

    -MAX Input Current 10A.

     

     

    SKU: n/a
  • Uni-T UT337 Carbon Monoxide Meter

    0 out of 5
    (0)

    Suitable for use everywhere from in the house to restaurants, offices and industrial areas, the UT337A measures the exact value of carbon monoxide (CO) present in the air. Featuring a built-in sensor integrated into the top of the unit, the UT337A measures CO content from 0-1000ppm with accuracy of ±5% (5ppm) and resolution of 1ppm. The sensor is also designed to adjust rapidly to changes, ensuring you always get a stable, accurate reading. When CO levels exceed a certain threshold, the UT337A will alert the user by using a combination of audible and LED light indicators. The alarm is configurable to the user’s specification and it is also possible to use this meter to calculate temperature values.

    SKU: n/a
  • CMM-10 Multimeter

    0 out of 5
    (0)
    • Autoranging/manual range selection.
    • DATA HOLD function, for holding measured values.
    • REL function, which allows you to make measurements relative to a stored reference value.
    • Continuity test with acoustic signalling (beeper).
    • AUTO-OFF function.
    • Display 3 7/8 digits (5000 max).
    SKU: n/a
  • UT601 Inductance Capacitance Meters

    0 out of 5
    (0)

    UT600 series RCL meter is a kind of 3.5-bithandheld digital meter with stable performance, safety, reliability, highaccuracy and manual range. It can be used to measure the magnification times β of audion, diode forward voltage drop and circuit continuity. UT601has wide capacitance measurement range from 0.1pF~20mF and highaccuracy. UT602 can hold data. UT 600 series is applicable to testingresistance, capacitance and inductance of electronic laboratory, productionline, maintenance point and teaching. It is the ideal tool of maintaining formany users

    SKU: n/a