  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • KT-80 Thermal Imager

    0 out of 5
    (0)

    Features and benefits of  Sonel KT:

    • Friendly UI, easy to use without training,
    • Affordable as entry level diagnostic tool,
    • Removable large capacity Li-ion battery,
    • 4 hour working time,
    • 3,5’’ large screen with no image cropping, high brightness screen to show image with no detailed information lost even outdoor or in highlight,
    • Rugged and compact design, metal internal structure,
    • Standard Micro USB interface for data transmission and charging,
    • Wi-Fi connection (Optional).
    SKU: n/a
  • YH 852D+ REWORK STATION

    0 out of 5
    (0)

    Features:

    1. Hot air and hot iron 2in1 rework soldering station
    2. Dual LED digital displays to show precision temperature
    3. SAMSUNG microcomputer control, quick warming-up
    4. Adjust the airflow and temperature control rotation easily
    5. Intelligence cool airflow features long service life of the machine and safe personal operation
    6. Automatically stop rotation
    7. ESD design of soldering iron to protect sensitive components
    8. High-quality resistance for durable use
    9. Stainless steel holder for placing the hot air gun
    10. Plastic stand for keeping the iron from flammable materials
    11. Voltage: 200V  to 240V 50/60Hz AC
    SKU: n/a
  • MC TIP OT IS

    0 out of 5
    (0)
    SKU: n/a
  • B&M BM802A Digital AC 1000A Clamp on Meter

    0 out of 5
    (0)
    Note: Products with electrical plugs are designed for use in the US. Outlets and voltage differ internationally and this product may require an adapter or converter for use in your destination. Please check compatibility before purchasing.
    SKU: n/a
  • TDR-410 Cable Fault Locator

    0 out of 5
    (0)
    • Features:

      • automatic or manual mode:
        • the automatic fault location (AFL),
        • mode with manual range selection and sensitivity,
        • single measurement triggered manually or scanning continuous,
      • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
      • maximum length of cable up to 4000 m one end of the cable,
      • “Dead zone” measure limited to 0.5 m,
      • 2.5 “LCD screen with backlight,
      • scan automatically or manually trigger,
      • sensitivity set manually or automatically adjusted,
      • adjustable impedance matching,
      • propagation coefficient adjustment 1% to 99%,
      • waterproof and resistant to mechanical housing.
      • small size and weight.
      • economical power system – 30 hours of continuously scan on one battery set..

      Accessories:

      • 0,6 m double-wire lead: WAPRZ0X6DZBB
      • red crocodile clip: WAKRORE20K02
      • Krokodylek czarny: WAKROBL20K01
      • cover M-2: WAFUTM2