  • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
  • Measurement of INRUSH current in start-up phase of electrical device.
  • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
  • Resistance measurement and continuity test:
    – continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
  • Capacitance measurement.
  • Temperature measurement (Fahrenheit or Celsius).
  • Frequency measurement.
  • Duty cycle measurement.
  • Diode test.

61,859 65,809

5 in stock

Compare
  • Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
    The instrument has an electronic overload protection of all functions and ranges.

Category:
Weight 0.6 kg
Dimensions 28 × 11 × 5 cm

AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.

Measurement of INRUSH current in start-up phase of electrical device.

AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 30 Ω.

Capacitance measurement

Temperature measurement (Fahrenheit or Celsius).

Frequency measurement.

Duty cycle measurement.

Diode test.

Additionally:

  • safe, insulated measuring clamp,
  • autoranging,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
  • „MAX/MIN” function,
  • over range indication,
  • „AUTO-OFF” function after 30 min.

Electric security:

  • measurement category: CAT IV 600 V acc. to EN 61010 – 1,
  • protection class acc. to EN 60529: IP20,

Other technical data:

  • power supply, 9 V battery type 6LR61,
  • display: 6600 counts, backlit LCD,
  • continuity test: threshold 30 Ω,
  • diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
  • low battery indication: BAT displayed,
  • over range indication: ‘OL’ displayed,
  • temperature sensor: type K thermocouple,
  • input impedance: ca.10 MΩ (V DC and V AC),
  • AC bandwidth: 50…500 Hz,
  • auto power OFF: 30 minutes,
  • dimensions: 281 x 108 x 53 mm,
  • weight: 570 g (with battery),
  • accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.

Rated operational conditions:

  • able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
  • operating temperature: 0…+50 °C,
  • storage temperature: -20…+60 °C,
  • operating altitude: max 2000 m.

 

DC current measurement

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 5 digits)
660…2000 A 1 A ±(3,0% m.v. + 5 digits) for 660…1000 A
±(5,0% m.v. + 5 digits) for 1000…2000 A

AC current measurement (TRUE RMS)

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 10 digits) for 50…60 Hz
±(3,0% m.v. + 10 digits) for 61…400 Hz
660…1500 A 1 A ±(2,5% m.v. + 10 digits) for 50…60 Hz
i 660…1000 A
±(3,5% m.v. + 10 digits) for 61…400 Hz
and 660…1000 A
±(5,0% m.v. + 10 digits) for 50…400 Hz
and 1000…1500

DC voltage measurement

Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(0,5% m.v. + 2 digits)
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…1000 V 1 V

AC voltage measurement (true RMS)

 

Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(1,5% m.v. + 8 digits)
for 50…500 Hz
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…750 V 1

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 5 digits)
0,660…6,599 kΩ 0,001 kΩ
6,60…65,99 kΩ 0,01 kΩ
66,0…659,9 kΩ 0,1 kΩ
0,660…6,599 MΩ 0,001 MΩ ±(2,0% m.v. + 5 digits)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

Capacitance measurement

Range Resolution Accuracy
0,0…6,599 nF 0,001 nF ±(3,0% m.v. + 30 digits)
6,60…65,99 nF 0,01 nF ±(3,0% m.v. + 10 digits)
66,0…559,9 nF 0,1 nF ±(3,0% m.v. + 30 digits)
6,600…59,999 µF 0,001 µF ±(3,0% m.v. + 10 digits)
66,00…659,99 µF 0,01 µF
660…659,999 µF 0,100 µF
0,660…6,600 mF 0,001 mF

Frequency measurement

Range Resolution Accuracy
10…65,99 Hz 0,01 Hz ±(0,1% m.v. + 5 digits)
66,0…659,9 Hz 0,1 Hz
0,660…6,599 kHz 0,001 kHz
6,60…65,99 kHz 0,01 kHz
66,0…659,9 kHz 0,1 kHz
0,660…1,000 MHz 0,001 MHz

Temperature measurement

Range Resolution Accuracy
-20…0°C 1°C ±(2,0% m.v. + 3°C)
0…399°C ±(1,0% m.v. + 2°C)
400…1000°C ±(2,0% m.v. + 3°C)
-4…31°F 1°F ±(2,0% m.v. + 6°F)
32..749°F ±(1,0% m.v. + 4°F)
750…1832°F ±(2,0% m.v. + 6°F)

 

Duty cycle measurement

 

ange Resolution Accuracy
5…95% 0,1% ±(2,0% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-2000 Digital clamp-on multimeter”

There are no reviews yet.

  • UT351 Sound Level Meters

    0 out of 5
    (0)

    UT350 series digital sound level meter with stable performance, safety and reliability can be widely used for environmental protection, laborhygiene, industrial enterprise, scientific research and teaching. It is applied to environmental noise measurement, machinery equipment noise measurement and architectural acoustics measurement.

    SKU: n/a
  • UNI-T Uti120T Pocket-Sized Infrared Camera with Real-Time Thermal Image Mini IR Thermal Imager with Large 3.5′′ LCD Touch Display

    (1)
    Features of UTi120T Thermal Imaging Camera
    • Thermal Imager has over 10,000 pixels to troubleshoot hot and cold spots
    • Adjustable emissivity from 0.10 to 0.99
    • Store and share images with optional microSD Card
    • Measure temperature range from -20°C to 400°C
    • Select color from total 6 palettes to best capture the event
    • Support WIFI
    • IP54 and 1m drop proof
    • Four display mode: thermal, visiable, blending.PIP
    • 7 colors palettes
    SKU: n/a
  • CLAMP METER AC CM 2030

    0 out of 5
    (0)

    Features

    . Digital clamp meter 266 opens 52mm.

    2. Large LCD display makes reading clear.

    3. Full function protection, strong anti-interferential performance.

    4. CE standard design, improves the safety of the test.

    5. Data hold.

    6. Clamp light and backlight display.

    SKU: n/a
  • SVC 2000VA

    0 out of 5
    (0)

    Input=120V 270
    Output=220
    Under and Over Volt Protection
    Surge Protection
    Over Load and Heat Protection
    Copper Wind with LCD Display

    SKU: n/a
  • UTD2072CEX-II Digital Storage Oscilloscope

    0 out of 5
    (0)

    1. 2 channels

    2. 70MHz/100MHz bandwidth; 1GSa/s real-time sampling rate
    3. Up to 28Mpts memory depth
    4. Calibration signal output: 10Hz, 100Hz, 1kHz (by default),
    10kHz or 100kHz
    5. Max 10Mpts waveform record
    6. 8-inch TFT LCD, WVGA (800X480)
    SKU: n/a