-6%

CMP-2000 Digital clamp-on multimeter

Availability:

5 in stock


It provides:

  • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
  • Measurement of INRUSH current in start-up phase of electrical device.
  • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
  • Resistance measurement and continuity test:
    – continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
  • Capacitance measurement.
  • Temperature measurement (Fahrenheit or Celsius).
  • Frequency measurement.
  • Duty cycle measurement.
  • Diode test.

61,859 65,809

5 in stock

Compare
  • Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
    The instrument has an electronic overload protection of all functions and ranges.

Category:
Weight 0.6 kg
Dimensions 28 × 11 × 5 cm

AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.

Measurement of INRUSH current in start-up phase of electrical device.

AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 30 Ω.

Capacitance measurement

Temperature measurement (Fahrenheit or Celsius).

Frequency measurement.

Duty cycle measurement.

Diode test.

Additionally:

  • safe, insulated measuring clamp,
  • autoranging,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
  • „MAX/MIN” function,
  • over range indication,
  • „AUTO-OFF” function after 30 min.

Electric security:

  • measurement category: CAT IV 600 V acc. to EN 61010 – 1,
  • protection class acc. to EN 60529: IP20,

Other technical data:

  • power supply, 9 V battery type 6LR61,
  • display: 6600 counts, backlit LCD,
  • continuity test: threshold 30 Ω,
  • diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
  • low battery indication: BAT displayed,
  • over range indication: ‘OL’ displayed,
  • temperature sensor: type K thermocouple,
  • input impedance: ca.10 MΩ (V DC and V AC),
  • AC bandwidth: 50…500 Hz,
  • auto power OFF: 30 minutes,
  • dimensions: 281 x 108 x 53 mm,
  • weight: 570 g (with battery),
  • accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.

Rated operational conditions:

  • able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
  • operating temperature: 0…+50 °C,
  • storage temperature: -20…+60 °C,
  • operating altitude: max 2000 m.

 

DC current measurement

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 5 digits)
660…2000 A 1 A ±(3,0% m.v. + 5 digits) for 660…1000 A
±(5,0% m.v. + 5 digits) for 1000…2000 A

AC current measurement (TRUE RMS)

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 10 digits) for 50…60 Hz
±(3,0% m.v. + 10 digits) for 61…400 Hz
660…1500 A 1 A ±(2,5% m.v. + 10 digits) for 50…60 Hz
i 660…1000 A
±(3,5% m.v. + 10 digits) for 61…400 Hz
and 660…1000 A
±(5,0% m.v. + 10 digits) for 50…400 Hz
and 1000…1500

DC voltage measurement

Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(0,5% m.v. + 2 digits)
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…1000 V 1 V

AC voltage measurement (true RMS)

 

Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(1,5% m.v. + 8 digits)
for 50…500 Hz
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…750 V 1

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 5 digits)
0,660…6,599 kΩ 0,001 kΩ
6,60…65,99 kΩ 0,01 kΩ
66,0…659,9 kΩ 0,1 kΩ
0,660…6,599 MΩ 0,001 MΩ ±(2,0% m.v. + 5 digits)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

Capacitance measurement

Range Resolution Accuracy
0,0…6,599 nF 0,001 nF ±(3,0% m.v. + 30 digits)
6,60…65,99 nF 0,01 nF ±(3,0% m.v. + 10 digits)
66,0…559,9 nF 0,1 nF ±(3,0% m.v. + 30 digits)
6,600…59,999 µF 0,001 µF ±(3,0% m.v. + 10 digits)
66,00…659,99 µF 0,01 µF
660…659,999 µF 0,100 µF
0,660…6,600 mF 0,001 mF

Frequency measurement

Range Resolution Accuracy
10…65,99 Hz 0,01 Hz ±(0,1% m.v. + 5 digits)
66,0…659,9 Hz 0,1 Hz
0,660…6,599 kHz 0,001 kHz
6,60…65,99 kHz 0,01 kHz
66,0…659,9 kHz 0,1 kHz
0,660…1,000 MHz 0,001 MHz

Temperature measurement

Range Resolution Accuracy
-20…0°C 1°C ±(2,0% m.v. + 3°C)
0…399°C ±(1,0% m.v. + 2°C)
400…1000°C ±(2,0% m.v. + 3°C)
-4…31°F 1°F ±(2,0% m.v. + 6°F)
32..749°F ±(1,0% m.v. + 4°F)
750…1832°F ±(2,0% m.v. + 6°F)

 

Duty cycle measurement

 

ange Resolution Accuracy
5…95% 0,1% ±(2,0% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-2000 Digital clamp-on multimeter”

There are no reviews yet.

  • JM-6108 Ratchet Screwdriver Bits Set

    0 out of 5
    (0)

     

    Features:

    • Ratchet screwdrivers with twist reverse and ratchet lock mechanism.
    • Contoured comfort grip handle. Supplied in storage case.
    • 180 degrees angle ratchet screwdriver.
    • Forward & Reverse with locking action.
    • Adjustable screwdriver bits for different screws.
    • Common used in automotive parts and home appliances.
    SKU: n/a
  • YH 900M K TIP

    0 out of 5
    (0)
    SKU: n/a
  • CLAMP METER AC BM 2000B

    0 out of 5
    (0)

    SPECIFICATIONS:

    – Maximum display: 1999
    – Method indication: LCD
    – Maximum arm span: 60mm
    – Operating temperature range:
    work: 0C – 40C
    Storage:-10C – 60C
    – Power supply: 9V battery
    – Low battery indication: YES, graphic symbol
    – Audible indication: YES, piezoelectric transducer
    – Dimensions: 270x100x45 mm
    – Weight: about 610g (with battery)

    Features
    – Measuring voltage: 0-1000V 2 range
    – Measurement of AC voltage: 0-700V in 1 range
    – Measurement of alternating current: 200A-2000A in 2 ranges
    – Measuring current: 200A-2000A in 2 ranges
    – Measurement of resistance: 2k in 1 range
    – Measuring capacity: NO
    – Frequency: NO
    – Temperature measurement: NO
    – Testing LEDs: YES
    – Acoustic continuity tester: YES
    – Distance between arms: 6cm
    – Meter dimensions: 270x100x45 mm
    – Weight: 610g with battery
    – Basic accuracy: ± (0.5% +2 digits)

    Packages Include:

    1 × Clamp-On Meter BM-2000B

    An internal link is any link from one page on your website to another page on your website. Both your users and search engines use links to find content on your website. Your users use links to navigate through your site and to find the content they want to find. Search engines also use links to navigate your site. They won’t find a page if there are no links to it. There are several types of internal links. In addition to links on your homepage,mean post feed, etc, you can also add links within your content. We call those contextual links. Contextual links point your users to interesting and related content.
    SKU: n/a
  • DIGITAL INSULATION / CONTINUITY TESTER MODEL 3005A

    0 out of 5
    (0)

    • Bargraph to display insulation resistance.
    • Displays the value of external AC voltage along with flashing symbol.
    • Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
    • Live circuit warning beeper.
    • Releasing the test button automatically discharges the charges stored in the circuit under test.
    • 200mA continuity measuring current to IEC 61557.
    • Minimum 1mA current on insulation tests to IEC 61557.

    SKU: n/a
  • YH 948DQ-II

    0 out of 5
    (0)
    SKU: n/a
  • JM-8146 47 in 1 Household Maintenance Tool

    0 out of 5
    (0)

    Multi-function Tools

    SKU: n/a