It provides:

  • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
  • Measurement of INRUSH current in start-up phase of electrical device.
  • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
  • Resistance measurement and continuity test:
    – continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
  • Capacitance measurement.
  • Temperature measurement (Fahrenheit or Celsius).
  • Frequency measurement.
  • Duty cycle measurement.
  • Diode test.

61,859 65,809

5 in stock

Compare
  • Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
    The instrument has an electronic overload protection of all functions and ranges.

Category:
Weight 0.6 kg
Dimensions 28 × 11 × 5 cm

AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.

Measurement of INRUSH current in start-up phase of electrical device.

AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 30 Ω.

Capacitance measurement

Temperature measurement (Fahrenheit or Celsius).

Frequency measurement.

Duty cycle measurement.

Diode test.

Additionally:

  • safe, insulated measuring clamp,
  • autoranging,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
  • „MAX/MIN” function,
  • over range indication,
  • „AUTO-OFF” function after 30 min.

Electric security:

  • measurement category: CAT IV 600 V acc. to EN 61010 – 1,
  • protection class acc. to EN 60529: IP20,

Other technical data:

  • power supply, 9 V battery type 6LR61,
  • display: 6600 counts, backlit LCD,
  • continuity test: threshold 30 Ω,
  • diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
  • low battery indication: BAT displayed,
  • over range indication: ‘OL’ displayed,
  • temperature sensor: type K thermocouple,
  • input impedance: ca.10 MΩ (V DC and V AC),
  • AC bandwidth: 50…500 Hz,
  • auto power OFF: 30 minutes,
  • dimensions: 281 x 108 x 53 mm,
  • weight: 570 g (with battery),
  • accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.

Rated operational conditions:

  • able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
  • operating temperature: 0…+50 °C,
  • storage temperature: -20…+60 °C,
  • operating altitude: max 2000 m.

 

DC current measurement

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 5 digits)
660…2000 A 1 A ±(3,0% m.v. + 5 digits) for 660…1000 A
±(5,0% m.v. + 5 digits) for 1000…2000 A

AC current measurement (TRUE RMS)

Range Resolution Accuracy
0,0…659,9 A 0,1 A ±(2,0% m.v. + 10 digits) for 50…60 Hz
±(3,0% m.v. + 10 digits) for 61…400 Hz
660…1500 A 1 A ±(2,5% m.v. + 10 digits) for 50…60 Hz
i 660…1000 A
±(3,5% m.v. + 10 digits) for 61…400 Hz
and 660…1000 A
±(5,0% m.v. + 10 digits) for 50…400 Hz
and 1000…1500

DC voltage measurement

Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(0,5% m.v. + 2 digits)
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…1000 V 1 V

AC voltage measurement (true RMS)

 

Range Resolution Accuracy
0,000…6,599 V 0,001 V ±(1,5% m.v. + 8 digits)
for 50…500 Hz
6,60…65,99 V 0,01 V
66,0…659,9 V 0,1 V
660…750 V 1

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 5 digits)
0,660…6,599 kΩ 0,001 kΩ
6,60…65,99 kΩ 0,01 kΩ
66,0…659,9 kΩ 0,1 kΩ
0,660…6,599 MΩ 0,001 MΩ ±(2,0% m.v. + 5 digits)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

Capacitance measurement

Range Resolution Accuracy
0,0…6,599 nF 0,001 nF ±(3,0% m.v. + 30 digits)
6,60…65,99 nF 0,01 nF ±(3,0% m.v. + 10 digits)
66,0…559,9 nF 0,1 nF ±(3,0% m.v. + 30 digits)
6,600…59,999 µF 0,001 µF ±(3,0% m.v. + 10 digits)
66,00…659,99 µF 0,01 µF
660…659,999 µF 0,100 µF
0,660…6,600 mF 0,001 mF

Frequency measurement

Range Resolution Accuracy
10…65,99 Hz 0,01 Hz ±(0,1% m.v. + 5 digits)
66,0…659,9 Hz 0,1 Hz
0,660…6,599 kHz 0,001 kHz
6,60…65,99 kHz 0,01 kHz
66,0…659,9 kHz 0,1 kHz
0,660…1,000 MHz 0,001 MHz

Temperature measurement

Range Resolution Accuracy
-20…0°C 1°C ±(2,0% m.v. + 3°C)
0…399°C ±(1,0% m.v. + 2°C)
400…1000°C ±(2,0% m.v. + 3°C)
-4…31°F 1°F ±(2,0% m.v. + 6°F)
32..749°F ±(1,0% m.v. + 4°F)
750…1832°F ±(2,0% m.v. + 6°F)

 

Duty cycle measurement

 

ange Resolution Accuracy
5…95% 0,1% ±(2,0% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-2000 Digital clamp-on multimeter”

There are no reviews yet.

  • UT251A

    0 out of 5
    (0)
    1. 4-digit LCD digital display, 10000 display count

    2. Auto range, 2/s sampling rate
    3. Peaks hold
    4. Store 99 sets of data
    5. RS-232 interface
    6. Data hold
    7. Auto power off
    8. Overload indication, low battery indication
    SKU: n/a
  • UT201+ ACA Digital Clamp Meters

    0 out of 5
    (0)

    1. Auto range and 3/s sampling rate

    2. Data hold

    3. Max value hold

    4. Auto power off

    5. Low battery prompt, over-range prompt and auto polarity display

    6. Comfortable tohold and easy to carry with (Product weight: 220g)

    7. 1m drop proof

    8. Complies with Double Insulationand Over Voltage standards of CAT II 600V, CAT III 300V and Pollution Degree 2

    9. Complies with CE (European Union) directives

    SKU: n/a
  • Insulation Resistance Testers UT513A

    0 out of 5
    (0)

    UT510 series is a kind of intelligent insulation tester. The device circuit design takes microcomputer technology design as the core and combines the large scale integrated circuit with digit circuit. It is equipped with strong measuring software and data processing software. It is applied to the parameter measurement of insulation resistance, voltage and low resistance. It has stable performance and simple operation. It is applicable to on-site measurement and repair of the electrical equipment and charging line. It is the ideal tool of maintaining electrical equipment. It is also used for smelting, communication, manufacture, fossil oil, national defense, electricity, chemical industry and circuit.

    SKU: n/a
  • TDGC 2000VA 300V

    0 out of 5
    (0)

    Input Voltage=220V/230V
    Output Voltage=0-300V
    Maximum Output Current=8
    Copper Wind
    LCD Output Display
    Three Pin Output Socket

    SKU: n/a