Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
The instrument has an electronic overload protection of all functions and ranges.
CMP-2000 Digital clamp-on multimeter
5 in stock
It provides:
- AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
- Measurement of INRUSH current in start-up phase of electrical device.
- AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
- Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω. - Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
₨61,859 ₨65,809
5 in stock
CompareWeight | 0.6 kg |
---|---|
Dimensions | 28 × 11 × 5 cm |
AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
Measurement of INRUSH current in start-up phase of electrical device.
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement
Temperature measurement (Fahrenheit or Celsius).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
- safe, insulated measuring clamp,
- autoranging,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
- „MAX/MIN” function,
- over range indication,
- „AUTO-OFF” function after 30 min.
Electric security:
- measurement category: CAT IV 600 V acc. to EN 61010 – 1,
- protection class acc. to EN 60529: IP20,
Other technical data:
- power supply, 9 V battery type 6LR61,
- display: 6600 counts, backlit LCD,
- continuity test: threshold 30 Ω,
- diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
- low battery indication: BAT displayed,
- over range indication: ‘OL’ displayed,
- temperature sensor: type K thermocouple,
- input impedance: ca.10 MΩ (V DC and V AC),
- AC bandwidth: 50…500 Hz,
- auto power OFF: 30 minutes,
- dimensions: 281 x 108 x 53 mm,
- weight: 570 g (with battery),
- accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.
Rated operational conditions:
- able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
- operating temperature: 0…+50 °C,
- storage temperature: -20…+60 °C,
- operating altitude: max 2000 m.
DC current measurement
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 5 digits) |
660…2000 A | 1 A | ±(3,0% m.v. + 5 digits) for 660…1000 A |
±(5,0% m.v. + 5 digits) for 1000…2000 A |
AC current measurement (TRUE RMS)
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 10 digits) for 50…60 Hz |
±(3,0% m.v. + 10 digits) for 61…400 Hz | ||
660…1500 A | 1 A | ±(2,5% m.v. + 10 digits) for 50…60 Hz i 660…1000 A |
±(3,5% m.v. + 10 digits) for 61…400 Hz and 660…1000 A |
||
±(5,0% m.v. + 10 digits) for 50…400 Hz and 1000…1500 |
DC voltage measurement
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(0,5% m.v. + 2 digits) |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…1000 V | 1 V |
AC voltage measurement (true RMS)
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(1,5% m.v. + 8 digits) for 50…500 Hz |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…750 V | 1 |
Resistance measurement
Range | Resolution | Accuracy |
0,0…659,9 Ω | 0,1 Ω | ±(1,0% m.v. + 5 digits) |
0,660…6,599 kΩ | 0,001 kΩ | |
6,60…65,99 kΩ | 0,01 kΩ | |
66,0…659,9 kΩ | 0,1 kΩ | |
0,660…6,599 MΩ | 0,001 MΩ | ±(2,0% m.v. + 5 digits) |
6,60…66,00 MΩ | 0,01 MΩ | ±(3,5% m.v. + 5 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
0,0…6,599 nF | 0,001 nF | ±(3,0% m.v. + 30 digits) |
6,60…65,99 nF | 0,01 nF | ±(3,0% m.v. + 10 digits) |
66,0…559,9 nF | 0,1 nF | ±(3,0% m.v. + 30 digits) |
6,600…59,999 µF | 0,001 µF | ±(3,0% m.v. + 10 digits) |
66,00…659,99 µF | 0,01 µF | |
660…659,999 µF | 0,100 µF | |
0,660…6,600 mF | 0,001 mF |
Frequency measurement
Range | Resolution | Accuracy |
10…65,99 Hz | 0,01 Hz | ±(0,1% m.v. + 5 digits) |
66,0…659,9 Hz | 0,1 Hz | |
0,660…6,599 kHz | 0,001 kHz | |
6,60…65,99 kHz | 0,01 kHz | |
66,0…659,9 kHz | 0,1 kHz | |
0,660…1,000 MHz | 0,001 MHz |
Temperature measurement
Range | Resolution | Accuracy |
-20…0°C | 1°C | ±(2,0% m.v. + 3°C) |
0…399°C | ±(1,0% m.v. + 2°C) | |
400…1000°C | ±(2,0% m.v. + 3°C) | |
-4…31°F | 1°F | ±(2,0% m.v. + 6°F) |
32..749°F | ±(1,0% m.v. + 4°F) | |
750…1832°F | ±(2,0% m.v. + 6°F) |
Duty cycle measurement
ange | Resolution | Accuracy |
5…95% | 0,1% | ±(2,0% m.v. + 10 digits) |
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMP-2000 Digital clamp-on multimeter”
-
Usb Tester
UT658LOAD USB Testers
Features of UT658 Series USB Testers
Certifications: CE, UKCA
● Type-A/C interface
● CE certification
● 10 sets of data storage
● Loop equivalent resistance measurement (1-480Ω)
● Same screen shows voltage, current, power, capacity, etc.
● Support fast charge protocol
SKU: n/a -
Function Generators
UTG2062B Function/Arbitrary Waveform Generator
1. 1μHz full-band resolution
2. 5MHz~30MHz pulse waveform, adjustable rise/fall time3. 14-bit/16-bit vertical resolution4. Two equivalent-performance channels5. Max arbitrary waveform length of 8k/16M points; 48/1616. non-volatile waveforms storageSKU: n/a -
Oscilloscopes
UTD2102CEX Digital Storage Oscilloscope
1. Dual analog channels width range 1mV/div~20V/div;
2. 7 inches widescreen LCD displays;
3. The new interface style;
4. Supports plug-and-play USB storage device. Communication with and remote control of computer through the USB device;
5. USB drive system software upgrade;
6. Storage of waveforms setups and interfaces waveforms and setups reproduction;
7. Automatic measurement of 32 waveform parameters;
8. Unique waveform recording and replay function;
9. Multilingual menu displays.SKU: n/a -
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a
There are no reviews yet.