-25%

CMP-400 Digital Clamp-On Multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,
  • AUTO-OFF function.

11,844 15,794

5 in stock

Compare

DC current measurement (CMP-401 only) and AC current.

AC/DC voltage measurement up to 600 V.
Resistance measurement and continuity test:
  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

Temperature measurement

Range Accuracy
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
-10 Hz ±(1,5% m.v. + 2 dgt)
  • sensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
4,000 A 0,001 A ±(2,5% m.v. + 12 dgt)
40,00 A 0,01 A ±(2,5% m.v. + 8 dgt)
400,0 A 0,1 A ±(2,8% m.v. + 8 dgt)
  • frequency range: 50…60 Hz.

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 dgt)
4,000 V 0,001 V ±(1,8% m.v. + 8 dgt)
40,00 V 0,01 V ±(1,8% m.v. + 8 dgt)
400,0 V 0,1 V ±(1,8% m.v. + 8 dgt)
600 V 1 V ±(2,5% m.v. + 8 dgt)
  • frequency range: 50 Hz…400 Hz

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 dgt)
4,000 V 0,001 V ±(1,5% m.v. + 2 dgt)
40,00 V 0,01 V ±(1,5% m.v. + 2 dgt)
400,0 V 0,1 V ±(1,5% m.v. + 2 dgt)
600 V 1 V ±(2% m.v. + 2 dgt)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v + 4 dgt)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

„m.v.”- measured value

Electric security:
– measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
– protection class acc. to EN 60529: IP40

Other technical data:
– power supply: 9 V battery type 6LR61
– display: 4000 counts, backlit LCD
– continuity test: I<0,5 mA, sound signal for R<50 Ω
– diode test: I = 0,3 mA, U0 = 1,5 V DC
– over range indication: 0L displayed
– sampling rate: 2 times per second
– input impedance: 10 MΩ (V DC and V AC)
– clamp size: opening 30 mm (1,2”)
– auto power OFF: approx. 30 min.
– dimensions: 197 x 70 x 40 mm
– weight: 183 g
– accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
– quality standard ISO 9001

Rated operational conditions:
– operating temperature: 0…+40°C
– storage temperature: -20…+60°C
– operating humidity: max 80% up to 31°C
decreasing linearly to 50% at 40°C
– operating altitude: max 2000 m

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-400 Digital Clamp-On Multimeter”

There are no reviews yet.

  • CLAMP METER AC CM 2030

    0 out of 5
    (0)

    Features

    . Digital clamp meter 266 opens 52mm.

    2. Large LCD display makes reading clear.

    3. Full function protection, strong anti-interferential performance.

    4. CE standard design, improves the safety of the test.

    5. Data hold.

    6. Clamp light and backlight display.

    SKU: n/a
  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a
  • UT373 Mini Tachometer

    0 out of 5
    (0)

    UT373 is a reliable digital non-contact tachometer used to measure rotation speed of motors and other machines. This device is able to display results in RPM or revolution count. This portable device is able to safely measure rotational objects through a non-intrusive method.

    SKU: n/a
  • UT612 LCR Meters

    0 out of 5
    (0)

    UT610 series is a handheld LCR digitalelectric bridge meter with stable performance, safety, reliability and autorange. It is professional to measure inductance, capacitance and resistance. Ithas the features of low power dissipation, high accuracy and fast speed. It canselect the series-parallel measurement mode; measure the quality factor ofcomponents, the loss, the phase angle, equivalent resistance and DC resistance.It can provide up to 5 kinds of frequency under the inductance, capacitance andresistance mode to satisfy the actual requirement.

     

    It is applicable to measuring and filtratingthe inductance, capacitance and resistance of lab, production line, maintenancepoint and teaching. It is the ideal tool of maintaining for many users.

    SKU: n/a