-11%

CMP-401 Digital Clamp-on multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,

AUTO-OFF function.

25,664 28,956

5 in stock

Compare

DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50 Ω.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement 
Diode test.
Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „REL” function,
  • over range indication,
  • „AUTO-OFF” function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 4000 counts, backlit LCD
  • continuity test: I<0,5 mA, sound signal for R<50 Ω
  • diode test: I = 0,3 mA, U0 = 1,5 V DC
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 10 MΩ (V DC and V AC)
  • clamp size: opening 30 mm (1,2”)
  • auto power OFF: approx. 30 min.
  • dimensions: 197 x 70 x 40 mm
  • weight: 183 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

Rated operational conditions:

  • operating temperature: 0…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
  • operating altitude: max 2000 m

 

Temperature measurement

Range Accuracy*
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
10 Hz … 10 kHz ±(1,5% m.v. + 2 digits)
  • csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 8 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
  • frequency range: 50…60 Hz.

 

DC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 5 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits)
4,000 V 0,001 V ±(1,5% m.v. + 5 digits)
40,00 V 0,01 V ±(1,5% m.v. + 5 digits)
400,0 V 0,1 V ±(1,5% m.v. + 5 digits)
600,0 V 1 V ±(2% m.v. + 5 digits)
  • frequency range: 50…400 Hz.

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits)
4,000 V 0,001 V ±(1,5% m.v. + 2 digits)
40,00 V 0,01 V ±(1,5% m.v. + 2 digits)
400,0 V 0,1 V ±(1,5% m.v. + 2 digits)
600,0 V 1 V ±(2% m.v. + 2 digits)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

 

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(4% m.v. + 20 digits)
400,0 nF 0,1 nF ±(3% m.v. + 5 digits)
4,000 nF 0,001 μF ±(3% m.v. + 5 digits)
40,00 nF 0,01 μF ±(3% m.v. + 5 digits)
100,0 nF 0,1 μF ±(4% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-401 Digital Clamp-on multimeter”

There are no reviews yet.

  • UT714 Multifunction Temperature Process Calibrator

    0 out of 5
    (0)

    The UT714 is powerful temperature calibrator that sources and measures thermocouples, RTDs, voltage, and resistance. It can be used to test and calibrate diffrent types of temperature instruments. This device is suitable for testing input/output temperature terminals such as sensors and transmitters.

    SKU: n/a
  • ,

    Jakemy JM-Z19 8X Optical Magnifier

    0 out of 5
    (0)

    1.the magnifier is make by ABS and resin.
    2.Working need 3 pcs AAA battery to light the 2 LED(not included in the package).
    3.Diameter:37MM
    4.Suitable:PCB repair,repair electronic etc.

    SKU: n/a
  • TDGC 500VA

    0 out of 5
    (0)

    Input Voltage=220V/230V
    Output Voltage=0-250V
    Maximum Output Current=2
    Copper Wind
    LCD Output Display

    SKU: n/a
  • UDP1306C Industrial Linear DC Power Supply

    0 out of 5
    (0)

    Features of UDP1306C Industrial Linear DC Power Supply:

    • 4-digit high precision display
    • OVP OCP OTP protection
    • Output setting viewable
    • Remote control (output ON/OFF)
    • Shutdown memory/keypad lock
    • Intelligent cooling fan
    • USB charging interface
    • RS232 program-controlled communication
    • USB device communication
    • 5 sets of data storage
    SKU: n/a