-11%

CMP-401 Digital Clamp-on multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,

AUTO-OFF function.

25,664 28,956

5 in stock

Compare

DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50 Ω.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement 
Diode test.
Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „REL” function,
  • over range indication,
  • „AUTO-OFF” function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 4000 counts, backlit LCD
  • continuity test: I<0,5 mA, sound signal for R<50 Ω
  • diode test: I = 0,3 mA, U0 = 1,5 V DC
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 10 MΩ (V DC and V AC)
  • clamp size: opening 30 mm (1,2”)
  • auto power OFF: approx. 30 min.
  • dimensions: 197 x 70 x 40 mm
  • weight: 183 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

Rated operational conditions:

  • operating temperature: 0…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
  • operating altitude: max 2000 m

 

Temperature measurement

Range Accuracy*
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
10 Hz … 10 kHz ±(1,5% m.v. + 2 digits)
  • csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 8 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
  • frequency range: 50…60 Hz.

 

DC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 5 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits)
4,000 V 0,001 V ±(1,5% m.v. + 5 digits)
40,00 V 0,01 V ±(1,5% m.v. + 5 digits)
400,0 V 0,1 V ±(1,5% m.v. + 5 digits)
600,0 V 1 V ±(2% m.v. + 5 digits)
  • frequency range: 50…400 Hz.

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits)
4,000 V 0,001 V ±(1,5% m.v. + 2 digits)
40,00 V 0,01 V ±(1,5% m.v. + 2 digits)
400,0 V 0,1 V ±(1,5% m.v. + 2 digits)
600,0 V 1 V ±(2% m.v. + 2 digits)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

 

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(4% m.v. + 20 digits)
400,0 nF 0,1 nF ±(3% m.v. + 5 digits)
4,000 nF 0,001 μF ±(3% m.v. + 5 digits)
40,00 nF 0,01 μF ±(3% m.v. + 5 digits)
100,0 nF 0,1 μF ±(4% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-401 Digital Clamp-on multimeter”

There are no reviews yet.

  • DIGITAL INSULATION / CONTINUITY TESTER MODEL 3007A

    0 out of 5
    (0)

    • Bargraph to display insulation resistance.
    • Displays the value of external AC voltage along with flashing symbol.
    • Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
    • Trac-Lok mode to conserve battery life on insulation and continuity tests.
    • Live circuit warning beeper.
    • Releasing the test button automatically discharges the charges stored in the circuit under test.
    • Backlight function to view the test results in dimly lit areas.
    • 200mA continuity measuring current to IEC 61557.
    • Minimum 1mA current on insulation tests to IEC 61557.

    SKU: n/a
  • LM120C Laser Distance Meters (Discontinued)

    0 out of 5
    (0)

    Features of LM80C/LM120C/LM200C Laser Distance Meters

    ● 2.4-inch color screen

    ● 12 measurement modes
    ● Electronic leveling
    ● 3 selectable measurement references
    ● USB 3.0 supply power
    ● 100 groups of data storage
    ● Rotatable screen
    ● Camera-aided measurement
    ● 2m drop test
    ● IP65 dust and water proof
    SKU: n/a
  • UPO2104CS 4 Channels Ultra Phosphor Oscilloscope

    0 out of 5
    (0)

    Features and Benefits:
    1、Sample Rate up to 1GS/s;
    2、Channels 4;
    3、Bandwidth 100MHz,;
    4、Memory Depth 28Mpts (Standard);
    5、Waveform Capture Rate up to 50,000wfms/s;
    6、With 256 level intensity grading display;
    7、Up to 65,000 frames for Waveform Record ,Replay;
    8、Support serial bus trigger and decoding;
    9、8 inches, TFT LCD,WVGA(800*480);
    10、Interface:USB Host, USB Device, LAN, VGA, AUX OUT, 10MHz input/output.

    SKU: UP21O02CSMHZ
  • CLAMP METER AC BM 801A

    0 out of 5
    (0)
    SKU: n/a
  • UT320A Mini Contact Type Thermometer

    0 out of 5
    (0)

    UT320A is a mini-type single-channel K/J thermometer, which ensures a wide range of product temperature measurement in high precision. It can be used with any K/J thermocouple probe.

    SKU: 4500
  • MECHANIC NS Series Soldering Paste NS48 [40g] 148℃

    0 out of 5
    (0)

    low temperature melting point 148, high reliability, not easy to

    take off the welding crack viscosity moderate, not easily offset

    bright spot run full, no virtual false welding welding, no residue

    SKU: n/a