Specifications Range UT202+
AC current (A) 400A ±(2%+10)
600A
AC current frequency (Hz) 50Hz~100Hz ±(1%+5)
AC voltage (V) 600V ±(0.8%+5)
AC voltage frequency(Hz) 10Hz~10kHz ±(1%+5)
10Hz~60kHz
Resistance (Ω) 40MΩ ±(0.8%+2)
60MΩ
Capacitance (F) 4mF ±(4%+5)
40mF
60mF
Temperature (℃) -40℃~1000℃ ±(1.5%+5)
Frequency (Hz) 10Hz~10MHz
Features
Display count 4000
Auto range
Jaw opening 28mm
True RMS
NCV
Live wire test
Continuity test
Diode
MAX/MIN
Relative mode
Zero mode
Data hold
Low battery indication
Auto power off
General Characterisitics
Power 1.5V battery (R03) x 2
Display 37mm x 25mm
Product color Red and grey
Product net weight 248g
Product size 215mm x 63mm x 36mm
Standard accessories Batteries, test leads, Themocouple
Standard individual packing Gift box, Carring bag, English manual
Standard quantity per carton 40pcs
Standard carton measurement 485mm x 295mm x 385mm
Standard carton gross weight 17.8kg

5,820 5,945

4 in stock

Compare
  • 1.Industrial electricity
  • 2.Residential electricity
  • 3.Air conditioning
  • 4.Automobile
Category:
Weight 0.3 kg
Dimensions 21 × 6 × 4 cm

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Digital Clamp Meter UT202+ UNI-T”

There are no reviews yet.

  • LM70 A Laser Distance Meters

    0 out of 5
    (0)

    Features of LM A Series Laser Distance Meters

    Certificates: CE, UKCA

    ● Ergonomic exterior, comfortable handling
    ● Millimeter accuracy
    ● 99 groups data storage
    ● Quick, self calculation with real-time readout
    ● Physical leveler(Horizontal and vertical)
    ● Multiple functions: Max/Min/continuous measurement, data storage, etc

    SKU: n/a
  • CLAMP METER AC DC CM 2056

    0 out of 5
    (0)

    Technical data

    Basic function

    Range

    Accuracy

    DCV

    400mV/4V/40V/400V/1000V

    ±(0.5%+5)

    ACV

    400mV/4V/40V/400V/750V

    ±(1.0%+5)

    DCA

    400A/1000A

    ±(2.0%+5)

    ACA

    400A/1000A

    ±(2.0%+5)

    Resistance

    400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ

    ±(0.8%+3)

    Capacitance

    4nF/40nF/400nF/4uF/40uF/200uF

    ±(3.5%+8)

    Frequency

    100Hz/1kHz/10kHz/100kHz/1MHz/10MHz

    ±(0.5%+4)

    Temperature

    (-40~ 1000) ℃ / (-40 ~1832) ℉

    ±(1.0%+5)

    Special function

    CM-2056

    NCV test

    True RMS test

    Diode test

    Continuity test

    Less than 50Ω±10Ω

    Low battery indicator

    Approx. less than 2.4 V

    Data hold

    Auto power off

    About 15 minutes

    Function protection

    Clamp light

    Backlight display

    Input impedance

    10MΩ

    Sampling rate

    3 times/s

    AC frequency response

    Current 50-60Hz/ voltage 50-400Hz

    Operation method

    Auto or manual range

    Max display

    4000

    Clamp opens

    52mm

    Battery

    3V (2*AAA battery)

    General Characteristic

    Meter color

    Orange and Black

    Meter weight

    About 280g (including battery)

    Meter size

    270×123×50mm

    Standard accessory

    Test leads, battery, manual, TP01 temperature probe

    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a
  • UPO1202CS

    0 out of 5
    (0)
    SKU: n/a
  • UT725 Multifunction Process Calibrator

    0 out of 5
    (0)

    Features of UT725 Multifunction Process Calibrator

    Certifications: CE, UKCA

    ● Step/ramp functions

    ● Source and measure accuracy up to 0.02%
    ● Rechargeable battery
    ● Contrast adjustment
    ● Auto power off (Time adjustable)
    ● Stores and recalls setups
    ● USB communication
    ● Simultaneously measure and output different process signal in real time
    ● Pressure measure with specified pressure modules, and sourcing pressure
    ● Provides 24V loop power to transmitter while conducting mA current measurement at the same time
    SKU: n/a