Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • SVC 10000VA

    0 out of 5
    (0)

    Input=120V 270
    Output=220
    Under and Over Volt Protection
    Surge Protection
    Over Load and Heat Protection
    Copper Wind with LCD Display

    SKU: n/a
  • UNI T Benchtop Digital Multimeter UT8802E

    0 out of 5
    (0)
    1. 20,000 Count EBTN LCD Display
    2. DC Voltage: 200mV/2V/20V/200V/1000V
    3. AC Voltage: 2V/20V/200V/750V
    4. DC Current: 200μA/2mA/20mA/200mA/20A
    5. AC Current: 2mA/20mA/200mA/20A
    6. Resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200MΩ
    7. Capacitance: 20nF/200nF/2μF/20μF/200μF/2mF/20mF/100mF
    8. Frequency: 200Hz~10MHz
    9. Duty cycle: 5%~99%
    10. Frequency response: 1 kHz
    11. USB Interface
    12. Data hold
    13. MAX/MIN
    14. Continuity buzzer
    15. Diode/transistor
    16. test
    17. CAT II 600V
    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a
  • YH 907L IRON

    0 out of 5
    (0)
    SKU: n/a
  • MECHANIC RD Series lead-free ESD soldering tip 900M-T-IS

    0 out of 5
    (0)

    MECHANIC RD Series lead-free ESD soldering tip 900M-T-IS

    Good heat conduction, fast heating, corrosion resistance, antistatic,long service life

    SKU: n/a