-19%

UT502A Insulation Resistance Tester

Availability:

Out of stock


1. 2000 count LCD display, overload indication, backlight

2. AC voltage measurement, auto power off
3. Auto discharge
4. Continuous measurements mode, red warning light and buzzer function
5. Continuous low resistance measurement
6.  PI and DAR measurement, auto resistivity calculation
7. Low resistance returning to zero function to improve accuracy

24,852 30,793

Out of stock

Compare
UT500 series insulation testers are used to measure the insulation resistance of electrical  equipment and household appliances. This is done by measuring the insulation resistance between electrical circuits or between circuits and ground. UT500 series can measure insulation resistance, AC Voltage, low resistance, PI (Polarization Index) and DAR (Dielectric Absorption). These are dieal  tools for ensuring transformers, genera-tors, high voltage motors, power capacitors, power cbles, arresters and other electrical equipment that can oprate in a safe and accurate manner.
Applications:
It is used for insulation resistance measurement for insulation materials and various kinds of electric equipments such as transformer, electric machines, cables, switches, electrical appliance, a ideal tool for electric maintenance, testing and inspection.
Category:
Weight 0.5 kg
Dimensions 15 × 10 × 7 cm
Specifications Range UT502A
Insulation resistance (Ω) Test voltages 500V/1000V/2500V 0%~10%
500V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
1000V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~5GΩ ±(5%+5)
2500V 0MΩ~99.9MΩ ±(3%+5)
100MΩ~9.9GΩ ±(5%+5)
10GΩ~20GΩ ±(10%+5)
Load current 50V (R=50kΩ) 1mA 0%~10%
100V (R=100kΩ) 1mA 0%~10%
250V (R=250kΩ) 1mA 0%~10%
500V (R=500kΩ) 1mA 0%~10%
1000V (R=1MΩ) 1mA 0%~10%
2500V (R=1MΩ) 1mA 0%~10%
Short-circuit current <2mA
Low resistance (Ω) 0.01Ω~200Ω (about 5.0V/>200mA) ±(2%+3)
AC voltage (V) 30V~600V ±(2%+3)
Features
Display count 2000
DAR 60s/15s and 60s/30s
PI
Auto range/Low battery indication
LCD backlight/Light alarm
Buzzer alarm/High voltage indication
Over load indication/Auto discharge
Test voltage secondary display
10MΩ internal resistance test
Meets IEC 61557 61557-1:2007; 61557-2:2007; 61557-4:2007
General Characterisitics
Power 1.5V battery (LR6) x 6
Display 70.6mm x 34mm
Product color Red and grey
Product net weight 500g
Product size 150mm x 100mm x 71mm
Standard accessories Batteries, test leads, alligator clips, gallus, test probes
Standard individual packing Gift box, carrying bag, English manual
Standard quantity per carton 20pcs
Standard carton measurement 500mm x 380mm x 330mm (0.063 CBM per standard carton)
Standard carton gross weight 18.9kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT502A Insulation Resistance Tester”

There are no reviews yet.

  • UT210E ACA DCA Digital Clamp Meters

    0 out of 5
    (0)

    Main Features

    1. Auto range, 2~3/s sampling rate

    2. True RMS measurement

    3. VFC, frequency conversion function

    4. NCV, Non-Contact Voltage testing function:induce electric field strength via the jaw

    5. Zero mode

    6. LCD backlight, data hold

    7. Auto power off, low battery indication and overload protection

    8. Comfortable to hold and easy to carry with (Product weight: 160g/170g)

    9. Complies with CE (European Union) directives

    SKU: n/a
  • Ut8805e Benchtop Digital Multimeter 5 1/2 Digits Digital Multimeter

    0 out of 5
    (0)
    Features
    1. True 5½-digit reading resolution
    2. Up to 5k rdgs/s sampling rate
    3.Multiple mathematical operations
    4. True-RMS,AC voltage range:750V,AC current range:10A
    5. Built-in thermocouple cold junction compensation
    6. Arbitrary sensor measurement
    7. 1Gb flash memory storage which can support up to 10k data recall
    8. With 4.3 inches TFT LCD. Pass/Fail
    9. Support USB, GPIB, RS-232C and LAN interface; support USB-TMC, IEEE 488.2 standard, VXI11 and SCPI language
    SKU: n/a
  • UT262A Non-Contact Phase Detector

    0 out of 5
    (0)

    UT262 series adopts clamp type non-contact measuring method, which means user doesn’t need to get in touch with high-voltage exposed wires. It can start detection after three super-induction and high-insulation clamps clamp the exterior of the three-phase wires, which is safer, more practical, and more effective. Beside phase sequence detection, UT262 series can be also used for live wire detection, simple electrical inspection, phase identification, missing-phase judgment, and wire breaker searching. It is a perfect tool for phase sequence detection, motor mounting, and wires maintenance.

    SKU: 22000
  • UT 205A+

    0 out of 5
    (0)
    1. 1000A AC current measurement
    2. 1000V AC/DC voltage measurement
    3. 600A inrush current measurement (UT206A+)
    4. Temperature  (UT206A+)
    5. NCV (UT206A+)
    6. ACV frequency 10Hz~10kHz
    7. Jaw opening: 45mm
    8. Resistance / capacitance / frequency measurement
    9. Auto range / backlight / low battery indication
    10. Continuity / diode / duty cycle
    11. MAX/MIN
    12. Data hold / flashlight / relative mode
    13. Auto power off
    14. CAT II 1000V/CAT III 600V
    SKU: n/a
  • UT61C Modern Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. Analogue bar graph

    2. Diode test and buzzer continuity

    3. Auto range

    4. MAX/MIN/REL measurement mode

    5. Overload protection for all ranges

    6. Data hold

    7. LCD backlight

    8. Equipped with RS232C and USB standard interface

    9. Complies with CE (European Union) directives

    SKU: n/a
  • YTH 109 PCB CUTTER

    0 out of 5
    (0)

    Suitable for cutting wire, electronic feet, trimming plastic products, cutting small metal wire, repairing of electronics industry, jewelry processing, model making and so on

    SKU: n/a