- Detection of wires and cables (live or not)
- detection of cables in ceilings, walls and floors,
- detection of breaks in cables,
- tracing cables in building installation,
- locating power points and switches in buildings,
- locating short circuits between leads,
- tracing shielded cables,
- tracing cables in metal ducts.
- Identification of fuses on the distribution board.
- Tracing underground cables.
- Tracing conductive water and heating pipelines.
- Non-contact detection of live cables.
LKZ-720 Wires and pipe locator
2 in stock
Features:
- the function 3D in the receiver – detecting the direction of current flow and accurate locating the object,
- phase detection mode,
- receiver operation with four transmitters at the same time to locate interruptions or distinguish wires,
- a LED bright torch,
- headphone socket in receiver,
- screens backlight for work in dark,
- transmission battery status and settings of the transmitter to the receiver
- operation in wide range of rated voltage, up to 500V RMS,
- measurement of voltage at the object to 500 Vrms,
- three levels of transmitter amplification,
- automatic or manual selection of transmitter operation modes,
- five modes of wire tracer operation – voltage, current, current-voltage, power and clamp,
- software upgrade via USB,
- additional accessories enable precise localization – such as contact or non-contact probes and measurement clamp.
₨200,000 ₨210,000
2 in stock
CompareElectric security:
- type of insulation: double, according to EN 61010-1
- measurement category: CAT III 600V acc. to EN 61010-1
- transmitter’s protection class acc. to EN 60529: IP67
- receiver’s protection class acc. to EN 60529: IP40
Other technical data:
- transmitter’s power supply: four AA alkaline battery or NiMH rechargeable battery
- transmitter’s max working voltage: 500 Vrms (707 Vampl)
- detector’s max range („I” mode) 2m
- non-contact neon max range: 20 cm (in air), 3 cm (in concrete)
- receiver’s power supply: battery 9V 6LR61 alkaline
Rated operational conditions:
- operating temperature -10°C…+50°C
Based on 0 reviews
Be the first to review “LKZ-720 Wires and pipe locator”
-
Multimeters
UT181A True RMS Datalogging Multimeter
1. Trend capture
2. Data logging: 200003. Data comparison4. 3.5-inch 64k color TFT LCD5. Dual temperature measurement6. Low pass filter7. 2200mAh Li-ion battery8. Real time and date9. Peak hold10. Bluetooth/APP11.USB interface cable /PC software CD12. IP65SKU: n/a -
Clamp Meters
CLAMP METER AC DC ET 8203
Descriptions:
1.This is a 5999 counts automatic digital clamp multimeter,small and compact design for easy carrying.
2.Stable performance,high precision,high reliability,clear reading and overload protection.
3.It is a ideal tool and instrument,laboratory,factory,radio enthusiasts and The ideal tool for the family.Specifications:
Brand:WINAPEX
Model: 8203
Color:Black
Jaw:40mm
Maximum display:5999
DC Voltage: 6V/60V/600V/1000V
AC Voltage: 6V/60V/600V/750V
AC Current: 60A/600A
DC Current: 60A/600A
Resistance(ohm):600Ω/6KΩ/60Ω/600KΩ/6MΩ/40MΩ
Capacitance:60nF/600nF/6uF/60uF/600uF/6mF/30mF
Frequency:10Hz/100Hz/1kHz/10Hz/100Hz/1MHz/10MHz
Temperature:(-20-1000 )℃/(0-1832 )℉
DC voltage DCV :yes
AC voltage ACV :yes
AC current ACA :yes
DC current DCA :yes
T-RMS:yes
NCV:yes
Square wave output:yes
On-Off Test :yes
Diode measurement:yes
Buzzer:yes
Zero line / Fire line test :yes
Data hold:yes
Material: Plastic, Electronic Parts
Battery: 2 x 1.5V AAA Batteries (not included)
Product size:176x67x33mm/6.86×2.61×1.29in
Product weight:305g/10.68ozPackage information:
Package weight:350g/12.25oz
Package size:210x80x35mm/8.19×3.12×1.37in
General Box PackagePackage included:
1 x Clamp Meter
1 x Pair of test leads
1 x Thermocouple
1 x User ManualNoted:
1.Cannot measure,there is no current through the ground wire,can only be measured as a single wire or zero Iine.
2.Cannot measure two or more lines at the same time.
3.A line contains two or more than two wire core can not be measured.SKU: n/a -
Earth Ground Resistance Testers
MRU-30 Earth Resistance and Resistivity Meter
-
It allows to take the measurements of:
- earthing resistance using auxiliary electrodes,
- earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
- earthing resistance using double clamps for measuring multiple earthing without underground connections.
- ground resistivity (Wenner method),
- continuity of equipotential bondings and protective
- conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.
Additionally:
- measurement of resistance of auxiliary electrodes RS and RH,
- measurement of interference voltage,
- measurement in the presence of interference voltage in the power network
- with frequency 50Hz, 60Hz,
- selection of maximum measuring voltage (25V and 50V),
- introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
- memory of 990 measurements (10 banks of 99 cells each),
- calibration of clamp used,
- data transmission to the computer (USB),
- indication of battery state.
SKU: n/a -
There are no reviews yet.