MIC-15k1 ,15kV Insulation Quality Analyzer

Availability:

1 in stock


 

Features:

  • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
  • It allows testing the electrical durability of the tested object – breakdown voltage indication.
  • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
  • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
  • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
    • visual method (if power cables are visible along the entire length),
    • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
  • Compatible with external software.

0

1 in stock

Compare

MIC-15k1 meter is designed to measure insulation resistance of power objects, i.e.:

  • single- and multicore cables,
  • transformers,
  • motors and generators,
  • capacitors, switches and other devices installed in power stations.

It is especially recommended for measurements in areas with very high electromagnetic disturbances, e.g. electrical substations with 1200 kV AC and 500 kV DC. Thanks to the 15 kV measuring voltage (in accordance with ANSI / NETA ATS-2009 TABLES 100.1) the meter can be used for measuring objects with a nominal voltage above 34.5 kV.

Category:
Weight 6.3 kg
Dimensions 39 × 31 × 17 cm

Insulation resistance measurement
Measuring range according to IEC 61557-2
UN = 15 000 V: 50 kΩ…40.0 TΩ
Measurement with DC and increasing voltage (SV) for UISO = 15 kV

Range Resolution Accuracy
0,0…999 kΩ 1 kΩ ±(3% m.v. + 10 digits)
1,00…9,99 MΩ 0,01 MΩ ±(3% m.v. + 10 digits)
10,0…99,9 MΩ 0,1 MΩ ±(3% m.v. + 10 digits)
100…999 MΩ 1 MΩ ±(3% m.v. + 10 digits)
1,00…9,99 GΩ 0,01 GΩ ±(3% m.v. + 10 digits)
10,0…99,9 GΩ 0,1 GΩ ±(3% m.v. + 10 digits)
100…999 GΩ 1 GΩ ±(3,5% m.v. + 10 digits)
1,00…9,99 TΩ 0,01 TΩ ±(7,5% m.v. + 10 digits)
10,0…20,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)
10,0…40,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)

Ranges of measured resistance depending on the test voltage

Voltage UISO Measuring range
50 V 200 GΩ
100 V 400 GΩ
250 V 1,00 TΩ
500 V 2,00 TΩ
1000 V 4,00 TΩ
2500 V 10,00 TΩ
5000 V 20,0 TΩ
10 000 V 40,0 TΩ
15 000 V 40,0 TΩ

Capacitance measurement

Range Resolution Accuracy
0…999 nF 1 nF ±(5% m.v. + 5 digits)
1,00…49,99 µF 0,01 µF ±(5% m.v. + 5 digits)
  • Displaying measured capacity after RISO measurement
  • For measurement voltages below 100 V the measurement error is not specified

Technical specification

  • type of insulation acc. to: EN 61010-1 and IEC 61557 double
  • measurement category acc. to EN 61010-1
    • IV 1000 V (operating altitude ≤2000 m)
    • IV 600 V (operating altitude ≤3000 m)
  • ingress protection acc. to EN 60529: IP67 (IP40 for closed case)
  • resistance to external interference voltages: up to 1550 V
  • resistance to external interference currents: up to 10 mA
  • advanced, digital filtering of interferences: 10 / 30 / 60 / 100 / 200 seconds
  • test leads lock: yes
  • power supply: Li-Ion 14.8 V rechargeable battery from network 90 V ÷ 260 V, 50 Hz/60 Hz
  • dimensions: 390 x 308 x 172 mm
  • weight: approx. 6.3 kg
  • storage temperature: -25ºC…+70ºC
  • operating temperature: -20ºC…+50ºC
  • humidity: 20%…90%
  • operating altitude: ≤3000 m
  • reference temperature: +23ºC ± 2ºC
  • reference humidity: 40%…60%
  • display: graphical LCD
  • number of RISO measurements with battery power supply: min. 1000 acc. to EN 61557-2
  • data transmission: USB and Bluetooth
  • quality standard: ISO 9001 compliant
  • device meets the requirements of standards: EN 61010-1 and IEC 61557
  • the product meets EMC requirements (immunity for industrial environment) with accordance to standards: EN 61326-1 and EN 61326-2-2

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-15k1 ,15kV Insulation Quality Analyzer”

There are no reviews yet.

  • JM-6108 Ratchet Screwdriver Bits Set

    0 out of 5
    (0)

     

    Features:

    • Ratchet screwdrivers with twist reverse and ratchet lock mechanism.
    • Contoured comfort grip handle. Supplied in storage case.
    • 180 degrees angle ratchet screwdriver.
    • Forward & Reverse with locking action.
    • Adjustable screwdriver bits for different screws.
    • Common used in automotive parts and home appliances.
    SKU: n/a
  • UT603 Inductance Capacitance Meters

    0 out of 5
    (0)

    UT600 series RCL meter is a kind of 3.5-bithandheld digital meter with stable performance, safety, reliability, highaccuracy and manual range. It can be used to measure the magnification times β of audion, diode forward voltage drop and circuit continuity. UT601has wide capacitance measurement range from 0.1pF~20mF and highaccuracy. UT602 can hold data. UT 600 series is applicable to testingresistance, capacitance and inductance of electronic laboratory, productionline, maintenance point and teaching. It is the ideal tool of maintaining formany users.

    SKU: n/a
  • RF-7050PRo+PO-88

    0 out of 5
    (0)
    SKU: n/a
  • LM 60 T Laser Tapes

    0 out of 5
    (0)

    Features of LM T Series Laser Tapes

    Certificates: CE, UKCA

    LM40T:

    ● One-button operation
    ● Single measurement
    ● Rear measurement reference
    ● Unit conversion
    ● Dual measurement methods
    ● Portable and compact

    LM60T:

    ● Single measurement

    ● Dual measurement mode
    ● Portable and compact
    ● Continuous measurement
    SKU: n/a
  • UT281A True RMS AC 3000A Flexible Clamp Meters

    0 out of 5
    (0)

    1. 2m drop proof, IP54, ETL/Intertek certified 3rd edition CE

    2. Coil diameter: 0.75cm, bending length: 24.5cm for UT281A and 45.7cm for UT281C

    3. Large LCD display for clear reading

    4. True RMS

    5. Long press INRUSH key for 2s to measure inrush current

    6. Data hold, backlight, auto power off

    SKU: n/a