- Insulation resistance measurement:
- selectable measurement voltage in the 100…2500 V range with 100 V step,
- continuous indication of insulation resistance or leakage current,
- automatic discharge of capacitance of tested object after the insulation resistance measurement,
- acoustic signalling of five-second periods to facilitate obtaining time characteristics,
- measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
- indication of actual test voltage during the measurement,
- protection against measuring live objects,
- two and three-lead measurement method,
- Continuity measurement of protective and equipotential conductors according to EN 61557-4
- with the >200 mA current.
- Leakage current measurement.
- Measurement of alternating and direct voltages in the 0…750 V range.
- Built-in rechargeable battery pack.
- The instruments meet the requirements of the EN 61557 standard.
- The ability to charge from car lighter (12 V) socket (additional accessories).
MIC-2501,2500V Insulation Resistance Meter
1 in stock
Electrical safety:
- type of insulation: double, in acc. with EN 61010-1 und IEC 61557
- measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
- case protection rating in acc. with EN 60529: IP65
Other technical specifications:
- power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
- weight of the meter: approx. 0,9 kg
- dimensions: 200 x 180 x 77 mm
- display: LCD segment display
- measurement results memory: 990 cells, 11880 records,
- transmission of measurement results: USB
₨0
1 in stock
CompareWeight | 0.9 kg |
---|---|
Dimensions | 20 × 18 × 8 cm |
Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)
Range | Resolution | Accuracy |
---|---|---|
0,0…999,9 kΩ | 0,1 kΩ | ±(3% m.v. + 20 digits) |
1,000…9,999 MΩ | 0,001 MΩ | ±(3% m.v. + 20 digits) |
10,00…99,99 MΩ | 0,01 MΩ | ±(3% m.v. + 20 digits) |
100,0…999,9 MΩ | 0,1 MΩ | ±(3% m.v. + 20 digits) |
1,000…9,999 GΩ | 0,001 GΩ | ±(3% m.v. + 20 digits) |
10,00…99,99 GΩ | 0,01 GΩ | ±(3% m.v. + 20 digits) |
100,0…999,9 GΩ | 0,1 GΩ | ±(3% m.v. + 20 digits) |
Values of measured resistance depending on measurement voltage
Voltage UISO | Measurement range |
---|---|
100 V | 50 GΩ |
200…400 V | 100 GΩ |
500…900 V | 250 GΩ |
1000…2400 V | 500 GΩ |
2500 V | 1000 GΩ |
Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω
Range | Resolution | Accuracy |
---|---|---|
0,00…19,99 Ω | 0,01 Ω | ±(2% m.v. + 3 digits) |
20,0…199,9 Ω | 0,1 Ω | ±(2% m.v. + 3 digits) |
200…999 Ω | 1 Ω | ±(4% m.v. + 3 digits) |
- Voltage on open terminals: 4…24 V
- Output current at R <2 Ω: ISC >200 mA
- Compensation of test lead resistance
- Current flowing in both directions, mean value of resistance is displayed
DC and AC voltage measurement
Range | Resolution | Accuracy |
---|---|---|
0…299,9 V | 0,1 V | ±(3% m.v. + 2 digits) |
300…750 V | 1 V | ±(3% m.v. + 2 digits) |
- Frequency range: 45…65 Hz
The acronym “m.v.” stands for a “measured reference value”.
Based on 0 reviews
Be the first to review “MIC-2501,2500V Insulation Resistance Meter”
-
Multimeters
UT81C Scope Digital Multimeter
UT81 series handheld digital oscilloscope multimeters combine oscilloscope and digital multimeter in one. Oscilloscope measurement mode includes signal input, data processing, auto measure, waveform storage, and transfer.
Multimeter mode features AC/DC voltage and current, resistance, diode, continuity, frequency, duty ratio, and capacitanceSKU: n/a -
Laser Distance Meters
UT395C Professional Laser Distance Meter
UT395 series are professional laser distance meters with color LCD display, electronic multi-axis leveler and other special features. Its unique operating system, friendly user interface, and personalized settings option all make these devices the perfect choice for professional distance measurement.
SKU: UN39C5T -
Wire & Cable Testers
TDR-420 Time Domain Reflectometer/ Cable Fault Locator
Product features
- Possibility damage-free location of impedance changes of tested cables and wires such as:
- shorted conductor,
- open conductor / end of cable – useful during the inventory of warehouses and stores,
- splice,
- splitter,
- water ingress,
- wet splice,
- bridge tap
- or other changes.
- Single measurement mode ONCE,
- Continuously measurement mode CONT,
- Tone signal generator TONE,
- Two cursors to mark two places of damage along with an indication of the distance between them,
- Built-in HELP function for easier interpretation of the reflectogram,
- 11 available measuring ranges from 7 m to 6000 m,
- „dead zone” limited to 0.6 m,
- Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
- manually set of sensitivity in 8 steps GAIN,
- output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
- Velocity of Propagation set in range from 10% to 99%,
- tight and durable housing with IP67 ingress protection degree.
- Small size and weight.
SKU: n/a - Possibility damage-free location of impedance changes of tested cables and wires such as:
-
Usb Tester
UT658C USB Testers
Features of UT658 Series USB Testers
Certifications: CE, UKCA
● Type-A/C interface
● CE certification
● 10 sets of data storage
● Loop equivalent resistance measurement (1-480Ω)
● Same screen shows voltage, current, power, capacity, etc.
● Support fast charge protocol
SKU: 0000 -
Laser Distance Meters
LM40 T Laser Tapes
Features of LM T Series Laser Tapes
Certificates: CE, UKCA
LM40T:
● One-button operation
● Single measurement
● Rear measurement reference
● Unit conversion
● Dual measurement methods
● Portable and compactLM60T:
● Single measurement
● Dual measurement mode● Portable and compact
● Continuous measurementSKU: n/a
There are no reviews yet.