Electrical safety:

  • type of insulation: double, in acc. with EN 61010-1 und IEC 61557
  • measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
  • case protection rating in acc. with EN 60529: IP65

Other technical specifications:

  • power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
  • weight of the meter: approx. 0,9 kg
  • dimensions: 200 x 180 x 77 mm
  • display: LCD segment display
  • measurement results memory: 990 cells, 11880 records,
  • transmission of measurement results: USB

0

1 in stock

Compare
  • Insulation resistance measurement:
    • selectable measurement voltage in the 100…2500 V range with 100 V step,
    • continuous indication of insulation resistance or leakage current,
    • automatic discharge of capacitance of tested object after the insulation resistance measurement,
    • acoustic signalling of five-second periods to facilitate obtaining time characteristics,
    • measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
    • indication of actual test voltage during the measurement,
    • protection against measuring live objects,
    • two and three-lead measurement method,
  • Continuity measurement of protective and equipotential conductors according to EN 61557-4
  • with the >200 mA current.
  • Leakage current measurement.
  • Measurement of alternating and direct voltages in the 0…750 V range.
  • Built-in rechargeable battery pack.
  • The instruments meet the requirements of the EN 61557 standard.
  • The ability to charge from car lighter (12 V) socket (additional accessories).
Category:
Weight 0.9 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0,0…999,9 kΩ 0,1 kΩ ±(3% m.v. + 20 digits)
1,000…9,999 MΩ 0,001 MΩ ±(3% m.v. + 20 digits)
10,00…99,99 MΩ 0,01 MΩ ±(3% m.v. + 20 digits)
100,0…999,9 MΩ 0,1 MΩ ±(3% m.v. + 20 digits)
1,000…9,999 GΩ 0,001 GΩ ±(3% m.v. + 20 digits)
10,00…99,99 GΩ 0,01 GΩ ±(3% m.v. + 20 digits)
100,0…999,9 GΩ 0,1 GΩ ±(3% m.v. + 20 digits)

Values of measured resistance depending on measurement voltage

 

Voltage UISO Measurement range
100 V 50 GΩ
200…400 V 100 GΩ
500…900 V 250 GΩ
1000…2400 V 500 GΩ
2500 V 1000 GΩ

Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω ±(2% m.v. + 3 digits)
200…999 Ω 1 Ω ±(4% m.v. + 3 digits)
  • Voltage on open terminals: 4…24 V
  • Output current at R <2 Ω: ISC >200 mA
  • Compensation of test lead resistance
  • Current flowing in both directions, mean value of resistance is displayed

DC and AC voltage measurement

Range Resolution Accuracy
0…299,9 V 0,1 V ±(3% m.v. + 2 digits)
300…750 V 1 V ±(3% m.v. + 2 digits)
  • Frequency range: 45…65 Hz

The acronym “m.v.” stands for a “measured reference value”.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-2501,2500V Insulation Resistance Meter”

There are no reviews yet.

  • YH N3H 7CM NOSLE

    0 out of 5
    (0)
    SKU: n/a
  • UT195DS Professional Digital Multimeters

    0 out of 5
    (0)

    1. IP65 rating, 2m drop proof, CAT III 1000V, CAT IV 600V

    2. Large 6000-count LCD screen

    3. 5/s sampling rate

    4. True RMS

    5. ACV 750V 5kHz bandwidth

    6. (AC+DC) or (AV+FREQ) , dual mode

    7. Flashlight

    8. Auto LCD backlight controlled by light sensor (can be turned off)

    9. LoZ voltage test, for ghost voltage measurement

    10. Motor phase sequence measurement with 2 probes

    11. 20A current measurement (max 30 seconds)

    12. 31 analogue bar

    13. Low pass filter, 1kHz 3dB attenuation

    SKU: n/a
  • TITAN TN 305DS DC Power Supply

    0 out of 5
    (0)

    Operating Conditions

    Supply power: AC 220-240V, 50Hz/60Hz.

    Working Temperature: -10°C ~ 40 °C

    Relative Humidity: ‹ 90%

    Storage Conditions: -10°C ~ 40 °C

    Relative Humidity: ‹ 80%

    Stable Voltage

    The output voltage is between 0 and nominal value continuously adjustable

    Voltage Stability: ≤0.01% +2mV

    Load Stability: ≤ 0.01% +2mV

    Recovery Time: ≤100µS

    Temperature Coefficient: ≤ 200PPM/°C

    Ripple Noise: ≤1 MVRMS(RMS)
    Stable Current

    Power Stability: 0.1% + 3mA

    Load Stability: 0.2% + 3mA

    Ripple Noise : ≤2mArms(RMS)

    The output current is between 0 and nominal value continuously adjustable

    SKU: n/a
  • UT61C Modern Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. Analogue bar graph

    2. Diode test and buzzer continuity

    3. Auto range

    4. MAX/MIN/REL measurement mode

    5. Overload protection for all ranges

    6. Data hold

    7. LCD backlight

    8. Equipped with RS232C and USB standard interface

    9. Complies with CE (European Union) directives

    SKU: n/a
  • MECHANIC Advanced silicone duster B110

    0 out of 5
    (0)

    MECHANIC Advanced silicone duster B110

    SKU: n/a
  • UT281E True RMS Flex Clamp

    0 out of 5
    (0)
    SKU: n/a