MIC-2501,2500V Insulation Resistance Meter

Availability:

1 in stock


 

Electrical safety:

  • type of insulation: double, in acc. with EN 61010-1 und IEC 61557
  • measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
  • case protection rating in acc. with EN 60529: IP65

Other technical specifications:

  • power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
  • weight of the meter: approx. 0,9 kg
  • dimensions: 200 x 180 x 77 mm
  • display: LCD segment display
  • measurement results memory: 990 cells, 11880 records,
  • transmission of measurement results: USB

0

1 in stock

Compare
  • Insulation resistance measurement:
    • selectable measurement voltage in the 100…2500 V range with 100 V step,
    • continuous indication of insulation resistance or leakage current,
    • automatic discharge of capacitance of tested object after the insulation resistance measurement,
    • acoustic signalling of five-second periods to facilitate obtaining time characteristics,
    • measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
    • indication of actual test voltage during the measurement,
    • protection against measuring live objects,
    • two and three-lead measurement method,
  • Continuity measurement of protective and equipotential conductors according to EN 61557-4
  • with the >200 mA current.
  • Leakage current measurement.
  • Measurement of alternating and direct voltages in the 0…750 V range.
  • Built-in rechargeable battery pack.
  • The instruments meet the requirements of the EN 61557 standard.
  • The ability to charge from car lighter (12 V) socket (additional accessories).
Category:
Weight 0.9 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0,0…999,9 kΩ 0,1 kΩ ±(3% m.v. + 20 digits)
1,000…9,999 MΩ 0,001 MΩ ±(3% m.v. + 20 digits)
10,00…99,99 MΩ 0,01 MΩ ±(3% m.v. + 20 digits)
100,0…999,9 MΩ 0,1 MΩ ±(3% m.v. + 20 digits)
1,000…9,999 GΩ 0,001 GΩ ±(3% m.v. + 20 digits)
10,00…99,99 GΩ 0,01 GΩ ±(3% m.v. + 20 digits)
100,0…999,9 GΩ 0,1 GΩ ±(3% m.v. + 20 digits)

Values of measured resistance depending on measurement voltage

 

Voltage UISO Measurement range
100 V 50 GΩ
200…400 V 100 GΩ
500…900 V 250 GΩ
1000…2400 V 500 GΩ
2500 V 1000 GΩ

Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω ±(2% m.v. + 3 digits)
200…999 Ω 1 Ω ±(4% m.v. + 3 digits)
  • Voltage on open terminals: 4…24 V
  • Output current at R <2 Ω: ISC >200 mA
  • Compensation of test lead resistance
  • Current flowing in both directions, mean value of resistance is displayed

DC and AC voltage measurement

Range Resolution Accuracy
0…299,9 V 0,1 V ±(3% m.v. + 2 digits)
300…750 V 1 V ±(3% m.v. + 2 digits)
  • Frequency range: 45…65 Hz

The acronym “m.v.” stands for a “measured reference value”.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-2501,2500V Insulation Resistance Meter”

There are no reviews yet.

  • CMP-2000 Digital clamp-on multimeter

    0 out of 5
    (0)

    It provides:

    • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
    • Measurement of INRUSH current in start-up phase of electrical device.
    • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
    • Resistance measurement and continuity test:
      – continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
    • Capacitance measurement.
    • Temperature measurement (Fahrenheit or Celsius).
    • Frequency measurement.
    • Duty cycle measurement.
    • Diode test.
    SKU: n/a
  • TITAN Clamp Multimeter TN88A in Pakistan

    0 out of 5
    (0)

    Specifications:

    • TITAN TN88A Digital Clamp Meter 500V Insulation Tester
    • DC voltage: 1000V ± (0.8% + 2)
    • AC voltage: 750V ± (1.2% + 4)
    • Alternating current: 200A / 1000A ± (2.5% + 5)
    • Resistance: 200Ω / 20kΩ ± (1.0% + 2)
    • Insulation test 100kΩ to 2000MΩ (with option 500V insulation tester unit)
    • High Resistance: 20MΩ / 2000MΩ ± (5.0% + 2)
    • The continuity of the alarm
    • Low screen voltage
    • Data retention
    • Input impedance: 10MΩ
    • Sampling rate: 3 times / s
    • Maximum display: 1999
    • Jaw opening: 50mm
    SKU: n/a
  • TDGC 1000VA

    0 out of 5
    (0)

    Input Voltage=220V/230V
    Output Voltage=0-250V
    Maximum Output Current=4
    Copper Wind
    LCD Output Display
    Three Pin Output Socket

    SKU: n/a
  • UT-L 17 Test Leads

    0 out of 5
    (0)
    SKU: n/a
  • DT 9205B+ DMM

    0 out of 5
    (0)

    Notes: Notes:
    1. Due to the difference between monitors, the picture may not reflect the actual color of the item.
    We guarantee the style is the same as shown in the pictures.
    2. Due to different personal measurement techniques, there may be 1-3 cm error of the physical.
    Thank you very much!

    SKU: n/a
  • LM100G Laser Distance Meters (Discontinued)

    0 out of 5
    (0)

    Features of LM50G/LM70G/LNM100G Laser Distance Meters

    ● LD green laser

    SKU: n/a