MIC-5001, 5000V Insulation Tester

Availability:

5 in stock


Insulation resistance measurement in a compact, light-weight, low-cost design.

  • Measurement to 5 TΩ
  • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
  • Continuous indication of insulation resistance or leakage current
  • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
  • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
  • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
  • Continuous display of test voltage during the measurement
  • Protection against measuring live objects
  • Two and three-lead measurement method
  • Ramp Test Insulation resistance measurement
  • Measurement of breakdown voltage with increments up to 1 kV / s
  • Measurement of alternating and direct voltages from 0 V to 750 V
  • 990 cells of memory (11880 records) to record results
  • Data transfer to PC via USB cable
  • Built-in rechargeable battery pack
  • Meets the requirements of the EN 61557 standard
  • Charge from optional car lighter (12 V) socket accessory

0

5 in stock

Compare

Insulation Resistance Meter

Category:
Weight 1 kg
Dimensions 20 × 18 × 8 cm

Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557- 2 for RISOmin=VISOnom/IISOmax…5 TΩ (IISOmax=1 mA)

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(3% m.v. + 20 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(3% m.v. + 20 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(3% m.v. + 20 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(3% m.v. + 20 digits)
1.000 to 5.000 TΩ 1 GΩ ±(4% m.v. + 50 digits)

Values of measured resistance depending on measurement voltage

Voltage VISO Measurement range
up to 100 V 50 GΩ
200 to 400 V 100 GΩ
500 to 900 V 250 GΩ
1000 to 2400 V 500 GΩ
2500 V 2500 GΩ
5000 V 5 TΩ

RampTest Insulation resistance measurement

Range Resolution Accuracy
0.0 to 999.9 kΩ 0.1 kΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 MΩ 0.001 MΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 MΩ 0.01 MΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 MΩ 0.1 MΩ ±(5% m.v. + 40 digits)
1.000 to 9.999 GΩ 0.001 GΩ ±(5% m.v. + 40 digits)
10.00 to 99.99 GΩ 0.01 GΩ ±(5% m.v. + 40 digits)
100.0 to 999.9 GΩ 0.1 GΩ ±(5% m.v. + 40 digits)
1.000 to 4.999 TΩ 0.001 TΩ ±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range Resolution Chosen UISO Accuracy
25.0 V to 99.0 V 0.1 V <600 V ± 5% m.v. ± 10 digits
100 V to 600 V 1 V <600 V ± 5% m.v. ± 4 digits
25 V to 999 V 1 V >600 V ± 5% m.v. ± 5 digits
1.00 kV to 5.00 kV 10V >600 V ± 5% m.v. ± 4 digits

DC and AC voltage measurement

Range Resolution Accuracy
0 to 299.9 V 0.1 V ±(3% m.v. + 2 digits)
300 to 750 V 1 V ±(3% m.v. + 2 digits)
  • frequency range: 45 to 65 Hz

VISO – measurement voltage
The acronym “m.v.” stands for a “measured reference value”

Electrical safety:

  • type of insulation double, in acc. with EN 61010-1 and IEC 61557
  • measurement category III 600 V (IV 300 V) in acc. EN 61010-1
  • case protection rating in acc. EN 60529 IP6529: IP65

Other technical specifications::

  • power supply of the meter NiMH 9.6 V – 2 Ah battery pack and power supply 12 V
  • weight of the meter approx. 0.9 kg, 2 lbs
  • dimensions 200 x 180 x 77 mm, 7.9 x 7 x 3 ins
  • LCD segment display
  • memory for measurement results:  990 cells, 11880 records
  • transfer of measurement results data via USB

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MIC-5001, 5000V Insulation Tester”

There are no reviews yet.

  • UT258A AC/DC Leakage Clamp Meter

    0 out of 5
    (0)

    UT258A is well designed for on-line measurement of DC/AC leakage current and current below 600V, which adopts latest CT and digital integration technology. Slender clamp is very suitable for places full of concentrated cables (such as, electric power metering system, high-speed rail system, automobile circuit maintenance and so on). Non-contact measurement ensures operation safety. The meter has mini shape with high accuracy, stable performance and perfect functions.

    SKU: n/a
  • ANALOG METER YX 960 TR

    0 out of 5
    (0)

    Features Of YX-960 TR Handheld Analog Multimeter:

    • Excellent DC resolution factor of 2mV.
    • Expanded resistance measurement from 020 to 200M.
    • Series capacitor DC to enable measurement of only AC components.
    • A large and bright meteor with a scale length of 80mm.
    • The sensitivity of 44pA at full scale.
    • Fuse and diode protection.
    • Measures hFE of transistor directly.
    SKU: n/a
  • Insulation Resistance Testers UT513A

    0 out of 5
    (0)

    UT510 series is a kind of intelligent insulation tester. The device circuit design takes microcomputer technology design as the core and combines the large scale integrated circuit with digit circuit. It is equipped with strong measuring software and data processing software. It is applied to the parameter measurement of insulation resistance, voltage and low resistance. It has stable performance and simple operation. It is applicable to on-site measurement and repair of the electrical equipment and charging line. It is the ideal tool of maintaining electrical equipment. It is also used for smelting, communication, manufacture, fossil oil, national defense, electricity, chemical industry and circuit.

    SKU: n/a
  • UT219DS ACA DCA Professional Clamp Meters with Motor LPF Test

    0 out of 5
    (0)
    • UT-219 professional clamp meter series is three-proofing digital clamp meter specially designed for professional industrial users.
    • The industrial design of this series is rugged and durable, and capable of withstanding the impact from 2 meters fall-down.
    • The waterproof rating is up to IP54; therefore, it can be used in environment with water splashing or much more dust.
    • The whole series is configured with LoZ (Low Impedance Input) AC voltage tap position, which is capable of testing the false voltage; auto backlight function can be used continuously under the circumstance of emergency power outage.
    • UT-219DS is also provided with MOTOR test function, allowing to directly test the phase sequence of three phase AC motor by means of the probe. UT-219 series is much more in compliance with CAT IV 600V safety level, and certified by the German GS institution.
    SKU: n/a
  • UTG2025A Function/Arbitrary Waveform Generator

    0 out of 5
    (0)

    1. 1μHz full-band resolution

    2. 5MHz~30MHz pulse waveform, adjustable rise/fall time
    3. 14-bit/16-bit vertical resolution
    4. Two equivalent-performance channels
    5. Max arbitrary waveform length of 8k/16M points; 48/161
    6. non-volatile waveforms storage
    SKU: n/a